Skip to main content
Log in

Bio- and chemiluminescence in bioanalysis

  • Review
  • Published:
Fresenius' Journal of Analytical Chemistry Aims and scope Submit manuscript

Abstract

Analytical chemiluminescence and bioluminescence represent a versatile, ultrasensitive tool with a wide range of applications in diverse fields such as biotechnology, pharmacology, molecular biology, clinical and environmental chemistry. Enzyme activities and enzyme substrates and inhibitors can be efficiently determined when directly involved in luminescent reactions, and also when they take part in a reaction suitable for coupling to a final light-emitting reaction. Chemiluminescence detection has been exploited in the fields of flow-injection analysis and column-liquid chromatographic and capillary-electrophoretic separative systems, due to its high sensitivity when compared with colorimetric detection. It has widely been used as an indicator of reactive oxygen species formation in cells and whole organs, thus allowing the study of a number of pathophysiological conditions related to oxidative stress. Chemiluminescence represents a sensitive and rapid alternative to radioactivity as a detection principle in immunoassays for the determination of a wide range of molecules (hormones, food additives, environmental pollutants) and in filter membrane biospecific reactions (Southern, Northern, Western, dot blot) for the determination of nucleic acids and proteins. Chemiluminescence has also been used for the sensitive and specific localization and quantitation of target analytes in tissue sections and single cells by immunohistochemistry and in situ hybridization techniques. A relatively recent application regards the use of luminescent reporter genes for the development of bioassays based on genetically engineered microorganisms or mammalian cells able to emit visible light in response to specific inorganic and organic compounds. Finally, the high detectability and rapidity of bio- and chemiluminescent detection make it suitable for the development of microarray-based high throughput screening assays, in which simultaneous, multianalyte detection is performed on multiple samples.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 11 October 1999 / Revised: 17 November 1999 / Accepted: 23 November 1999

Rights and permissions

Reprints and permissions

About this article

Cite this article

Roda, A., Pasini, P., Guardigli, M. et al. Bio- and chemiluminescence in bioanalysis. Fresenius J Anal Chem 366, 752–759 (2000). https://doi.org/10.1007/s002160051569

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002160051569

Keywords

Navigation