Skip to main content
Log in

Capabilities and limits of ICP-MS for direct determination of element traces in saline solutions

  • Lecture
  • Published:
Fresenius' Journal of Analytical Chemistry Aims and scope Submit manuscript

Abstract

An ICP-MS method for the determination of ultra-traces of 24 Elements (Li, Be, Mg, Al, Cr, Mn, Co, Zn, Cu, Ga, As, Se, Rb, Sr, Mo, Ag, Cd, Sn, Sb, Ba, Tl, Pb, Bi, U) at ng/L to μg/L levels in highly saline solutions (up to 30 g/L NaCl) was developed. Calculated to the salt content of the samples, limits of detection at the sub-μg/kg level were obtained. This allows the measurement of samples like sea water, or clinical samples like urine, serum and whole blood, with few or without sample preparation and a drastic improvement to the limits of detection. Compared to the determination in solutions of 1 g/L NaCl the limits of detection in the original sample were improved by one order of magnitude. Improvements in instrumental stability are achieved by the use of an additional gas, that is introduced to the aerosol stream and avoids salt deposition in the aerosol tube of the torch, the use of High Matrix Content (HMC) cones, that show no clogging even at NaCl-concentrations up to 50 g/L. With this setup the long term stability for measurements with changing matrix concentrations is < 10% without and < 5% with use of an internal standard for the individual samples. Cleaning up is necessary after 2 days of operation. The direct analysis of the Nearshore Seawater Reference Material NRC-CNRC CASS3 showed a good agreement with the certified and measured concentrations. Elements, that do not suffer from an isobaric overlap of matrix compounds can be determined clearly at ng/L levels. Measurement of different matrix concentrations showed, that acceptable results can be achieved with a single calibration for concentrations from 5 g/L NaCl to 30 g/L NaCl, though matrix matching shows the best results.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 29 November 1996 / Revised: 21 January 1997 / Accepted: 25 March 1997

Rights and permissions

Reprints and permissions

About this article

Cite this article

Falk, H., Geerling, R., Hattendorf, B. et al. Capabilities and limits of ICP-MS for direct determination of element traces in saline solutions. Fresenius J Anal Chem 359, 352–356 (1997). https://doi.org/10.1007/s002160050585

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002160050585

Keywords

Navigation