Abstract
The feasibility of fabricating copper-sensitive chemically modified electrodes (CMEs) for trace analysis in aqueous and in 40% (v/v) ethanol-water media was investigated. Carbon paste electrodes modified with crown ethers were constructed by mixing the crown ethers into a graphite powder-paraffin oil matrix. The electrodes so formed were able to bind Cu(II) ions chemically and gave better voltammetric responses than the unmodified ones. The crown ethers studied and compared were 15-crown-5, benzo-15-crown-5 and dibenzo-18-crown-6. With a 3% benzo-15-crown-5 CME, Cu(II) could be quantified at sub-ppm levels by differential pulse voltammetry with a detection limit of 0.05 ppm. By differential pulse anodic stripping voltammetry Cu(II) could be quantified over the range 1 to 100 ppb. Interference from metal ions like Ni(II), Co(II), Mn(II), Fe(II), etc. have also been studied. The method was successfully applied to artificial as well as commercial samples of alcoholic beverages.
Similar content being viewed by others
Author information
Authors and Affiliations
Additional information
Received: 12 January 2000 / Revised: 14 March 2000 / Accepted: 16 March 2000
Rights and permissions
About this article
Cite this article
Ijeri, V., Srivastava, A. Voltammetric determination of copper at chemically modified electrodes based on crown ethers. Fresenius J Anal Chem 367, 373–377 (2000). https://doi.org/10.1007/s002160000411