Cellphone-based detection platform for rbST biomarker analysis in milk extracts using a microsphere fluorescence immunoassay

  • Research Paper
  • Published:
Analytical and Bioanalytical Chemistry Aims and scope Submit manuscript

Abstract

Current contaminant and residue monitoring throughout the food chain is based on sampling, transport, administration, and analysis in specialized control laboratories. This is a highly inefficient and costly process since typically more than 99 % of the samples are found to be compliant. On-site simplified prescreening may provide a scenario in which only samples that are suspect are transported and further processed. Such a prescreening can be performed using a small attachment on a cellphone. To this end, a cellphone-based imaging platform for a microsphere fluorescence immunoassay that detects the presence of anti-recombinant bovine somatotropin (rbST) antibodies in milk extracts was developed. RbST administration to cows increases their milk production, but is illegal in the EU and a public health concern in the USA. The cellphone monitors the presence of anti-rbST antibodies (rbST biomarker), which are endogenously produced upon administration of rbST and excreted in milk. The rbST biomarker present in milk extracts was captured by rbST covalently coupled to paramagnetic microspheres and labeled by quantum dot (QD)-coupled detection antibodies. The emitted fluorescence light from these captured QDs was then imaged using the cellphone camera. Additionally, a dark-field image was taken in which all microspheres present were visible. The fluorescence and dark-field microimages were analyzed using a custom-developed Android application running on the same cellphone. With this setup, the microsphere fluorescence immunoassay and cellphone-based detection were successfully applied to milk sample extracts from rbST-treated and untreated cows. An 80 % true-positive rate and 95 % true-negative rate were achieved using this setup. Next, the cellphone-based detection platform was benchmarked against a newly developed planar imaging array alternative and found to be equally performing versus the much more sophisticated alternative. Using cellphone-based on-site analysis in future residue monitoring can limit the number of samples for laboratory analysis already at an early stage. Therewith, the entire monitoring process can become much more efficient and economical.

Cellphone-based detection platform for rbST biomarker analysis in milk extracts using a microsphere fluorescence immunoassay

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Commission Decision 2002/657/EC of 12 August 2002 implementing Council Directive 96/23/EC concerning the performance of analytical methods and the interpretation of results. Off J Eur Commun L 221: 8–36

  2. Zhu H, Ozcan A (2013) Wide-field fluorescent microscopy and fluorescent imaging flow cytometry on a cell-phone. JoVE 74:e50451

    Google Scholar 

  3. Zhu H, Mavandadi S, Coskun AF, Yaglidere O, Ozcan A (2011) Optofluidic fluorescent imaging cytometry on a cell phone. Anal Chem 83(17):6641–6647

    Article  CAS  Google Scholar 

  4. Zhu H, Sikora U, Ozcan A (2012) Quantum dot enabled detection of Escherichia coli using a cell-phone. Analyst 137(11):2541–2544

    Article  CAS  Google Scholar 

  5. Zhu H, Yaglidere O, Su TW, Tseng D, Ozcan A (2011) Cost-effective and compact wide-field fluorescent imaging on a cell-phone. Lab Chip 11(2):315–322

    Article  CAS  Google Scholar 

  6. Chaiyabutr N, Thammacharoen S, Komolvanich S, Chanpongsang S (2005) Effects of long-term administration of recombinant bovine somatotropin on milk production and plasma insulin-like growth factor and insulin in crossbred Holstein cows. J Agric Sci 143(04):311–318

    Article  CAS  Google Scholar 

  7. Council Decision 1999/879/EC of 17 December 1999 concerning the Placing on the Market and Administration of bovine Somatotrophin (BST) and repealing Decision 90/218/EEC, Off. J. Eur. Commun. L331: 71–72

  8. Ludwig SKJ, Smits NGE, van der Veer G, Bremer MGEG, Nielen MWF (2012) Multiple protein biomarker assessment for recombinant bovine somatotropin (rbST) abuse in cattle. PLoS ONE 7(12):e52917

    Article  CAS  Google Scholar 

  9. Ludwig SKJ, Smits NGE, Bremer MGEG, Nielen MWF (2012) Monitoring milk for antibodies against recombinant bovine somatotropin using a microsphere immunoassay-based biomarker approach. Food Control 26(1):68–72

    Article  CAS  Google Scholar 

  10. Vashist SK, Mudanyali O, Schneider EM, Zengerle R, Ozcan A (2013) Cellphone-based devices for bioanalytical sciences. Anal Bioanal Chem. doi:10.1007/s00216-013-7473-1

    Google Scholar 

  11. Smits NGE, Ludwig SKJ, Van der Veer G, Bremer MGEG, Nielen MWF (2013) Multiplex flow cytometric immunoassay for serum biomarker profiling of recombinant bovine somatotropin. Analyst 138(1):111–117

    Article  CAS  Google Scholar 

  12. Metz CE (1978) Basic principles of ROC analysis. Semin Nucl Med 8(4):283–298

    Article  CAS  Google Scholar 

  13. Zhu H, Sencan I, Wong J, Dimitrov S, Tseng D, Nagashima K, Ozcan A (2013) Cost-effective and rapid blood analysis on a cell-phone. Lab Chip 13(7):1282–1288

    Article  CAS  Google Scholar 

  14. Breslauer DN, Maamari RN, Switz NA, Lam WA, Fletcher DA (2009) Mobile phone based clinical microscopy for global health applications. PLoS ONE 4(7):e6320

    Article  Google Scholar 

  15. Coskun AF, Wong J, Khodadadi D, Nagi R, Tey A, Ozcan A (2013) A personalized food allergen testing platform on a cellphone. Lab Chip 13(4):636–640

    Article  CAS  Google Scholar 

  16. Gallegos D, Long KD, Yu H, Clark PP, Lin Y, George S, Nath P, Cunningham BT (2013) Label-free biodetection using a smartphone. Lab Chip 13(11):2124–2132

    Article  CAS  Google Scholar 

  17. Lu Y, Shi W, Qin J, Lin B (2009) Low cost, portable detection of gold nanoparticle-labeled microfluidic immunoassay with camera cell phone. Electrophoresis 30(4):579–582

    Article  CAS  Google Scholar 

  18. Martinez AW, Phillips ST, Carrilho E, Thomas SW, Sindi H, Whitesides GM (2008) Simple telemedicine for developing regions: camera phones and paper-based microfluidic devices for real-time. Off-Site Diagn Anal Chem 80(10):3699–3707

    Article  CAS  Google Scholar 

  19. Mudanyali O, Dimitrov S, Sikora U, Padmanabhan S, Navruz I, Ozcan A (2012) Integrated rapid-diagnostic-test reader platform on a cellphone. Lab Chip 12(15):2678–2686

    Article  CAS  Google Scholar 

  20. Terry M (2011) Medical connectivity telemicroscopes and point-of-care diagnostics team up with smartphones. Telemed J e-Health 17(5):320–323

    Article  Google Scholar 

  21. Smith ZJ, Chu K, Espenson AR, Rahimzadeh M, Gryshuk A, Molinaro M, Dwyre DM, Lane S, Matthews D, Wachsmann-Hogiu S (2011) Cell-phone-based platform for biomedical device development and education applications. PLoS ONE 6(3):e17150

    Article  CAS  Google Scholar 

  22. Tseng D, Mudanyali O, Oztoprak C, Isikman SO, Sencan I, Yaglidere O, Ozcan A (2010) Lensfree microscopy on a cellphone. Lab Chip 10(14):1787–1792

    Article  CAS  Google Scholar 

  23. Wei Q, Qi H, Luo W, Tseng D, Ki SJ, Wan Z, Göröcs Z, Bentolila LA, Wu T-T, Sun R, Ozcan A (2013) Fluorescent imaging of single nanoparticles and viruses on a smart phone. ACS Nano 7(10):9147–9155

    Article  CAS  Google Scholar 

  24. Zhu H, Isikman SO, Mudanyali O, Greenbaum A, Ozcan A (2013) Optical imaging techniques for point-of-care diagnostics. Lab Chip 13(1):51–67

    Article  CAS  Google Scholar 

  25. Navruz I, Coskun AF, Wong J, Mohammad S, Tseng D, Nagi R, Phillips S, Ozcan A (2013) Smart-phone based computational microscopy using multi-frame contact imaging on a fiber-optic array. Lab Chip 13(20):4015–4023

    Article  CAS  Google Scholar 

  26. Le Breton M-H, Rochereau-Roulet S, Pinel G, Cesbron N, Le Bizec B (2009) Elimination kinetic of recombinant somatotropin in bovine. Anal Chim Acta 637(1–2):121–127

    Article  Google Scholar 

Download references

Acknowledgments

This project was financially supported by the Dutch Ministry of Economic Affairs (project 1227202901). The authors would like to thank Jan Schouten for technical assistance, Jeroen Peters for help on figure preparation, and Falko Quinger for image preparation for the graphical abstract. Ozcan Research Group at UCLA acknowledges the support of the Presidential Early Career Award for Scientists and Engineers (PECASE), Army Research Office (ARO) Life Sciences Division, ARO Young Investigator Award, National Science Foundation (NSF) CAREER Award, NSF CBET Biophotonics Program, NSF EFRI Award, Office of Naval Research (ONR) Young Investigator Award, and National Institutes of Health (NIH) Director’s New Innovator Award DP2OD006427 from the Office of the Director, National Institutes of Health.

Author information

Authors and Affiliations

Authors

Corresponding authors

Correspondence to Michel W. F. Nielen or Aydogan Ozcan.

Additional information

Published in the topical collection Advanced Food Analysis with guest editors Michel W.F. Nielen, Jana Hajslova, and Rudolf Krska.

Electronic supplementary material

Below is the link to the electronic supplementary material.

ESM 1

(PDF 619 kb)

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ludwig, S.K.J., Zhu, H., Phillips, S. et al. Cellphone-based detection platform for rbST biomarker analysis in milk extracts using a microsphere fluorescence immunoassay. Anal Bioanal Chem 406, 6857–6866 (2014). https://doi.org/10.1007/s00216-014-7984-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00216-014-7984-4

Keywords

Navigation