A novel approach to measure isotope ratios via multi-collector—inductively coupled plasma—mass spectrometry based on sample mixing with a non-enriched standard

  • Research Paper
  • Published:
Analytical and Bioanalytical Chemistry Aims and scope Submit manuscript

Abstract

In this work, a novel approach to measure isotope ratios via multi-collector—inductively coupled plasma—mass spectrometry (MC-ICP-MS) for low amounts of target element is proposed. The methodology is based on mixing of the sample (target element isolate) with a non-enriched in-house standard, previously characterized for its isotopic composition. This methodology has been applied to isotopic analysis of Cu and of Fe in whole blood samples. For this purpose, different mixtures of sample + in-house standard were prepared and adjusted to a final concentration of 500 μg/L of the target elements for isotopic analysis. δ65Cu, δ56Fe, and δ57Fe varied linearly as a function of the amount of in-house standard (or of sample) present in the mixture. The isotopic composition of the sample was calculated considering the isotope ratios measured for (i) the mixture and (ii) the in-house standard and (iii) the relative concentrations of target element contributed by the sample and the standard to the mixture, respectively. For validation purposes, the isotopic analysis of whole blood Cu was carried out using both the conventional (using 2 mL of whole blood) and the newly developed approach (using 500 μL of whole blood). The δ65Cu values obtained using mixtures containing 40 % (200 μg/L) of Cu from the blood samples and 60 % (300 μg/L) of Cu from the in-house standard were in good agreement with the δ65Cu value obtained using the conventional approach (bias ≤0.15 ‰).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Vanhaecke F, Degryse P (2012) Isotopic analysis–fundamentals and applications using ICP-MS. Wiley–VCH, Verlag

  2. Johnson CM, Beard BL, Albarède F (2004) Geochemistry of non-traditional stable isotopes. Rev Mineral Geochem 55:1–24

    Article  CAS  Google Scholar 

  3. Maréchal C, Albarede F (2002) Ion-exchange fractionation of copper and zinc isotopes. Geochim Cosmochim Acta 66:1499–1509

    Article  Google Scholar 

  4. Yang L (2009) Accurate and precise determination of isotopic ratios by MC-ICP-MS: a review. Mass Spectrom Rev 28:990–1011

    Article  CAS  Google Scholar 

  5. Meija J, Yang L, Sturgeon R, Mester Z (2009) Mass bias fractionation laws for multi-collector ICPMS: assumptions and their experimental verification. Anal Chem 81:6774–6778

    Article  CAS  Google Scholar 

  6. Van Heghe L, Delanghe J, Van Vlierberghe H, Vanhaecke F (2013) The relationship between the iron isotopic composition of human whole blood and iron status parameters. Metallomics 5:1503–1509

    Article  Google Scholar 

  7. Aramendía M, Rello L, Resano M, Vanhaecke F (2013) Isotopic analysis of Cu in serum samples for diagnosis of Wilson's disease: a pilot study. J Anal At Spectrom 28:675–681

    Article  Google Scholar 

  8. Boulyga SF, Klötzli U, Prohaska T (2006) Improved abundance sensitivity in MC-ICP-MS for determination of 236U/238U isotope ratios in the 107 to 108 range. J Anal Atom Spectrom 21:1427–1430

    Article  CAS  Google Scholar 

  9. Huang KF, Blusztajn J, Oppo DW, Curry WB, Peucker-Ehrenbrink B (2012) High-precision and accurate determinations of neodymium isotopic compositions at nanogram levels in natural materials by MC-ICP-MS. J Anal At Spectrom 27:1560–1567

    Article  CAS  Google Scholar 

  10. Huang KF, You CF, Liu YH, Wang RM, Lin PY, Chung CH (2010) Low-memory, small sample size, accurate and high-precision determinations of lithium isotopic ratios in natural materials by MC-ICP-MS. J Anal At Spectrom 25:1019–1024

    Article  CAS  Google Scholar 

  11. Makishima A, Nakamura E (2010) Precise isotopic determination of Hf and Pb at sub-nano gram levels by MC-ICP-MS employing a newly designed sample cone and a pre-amplifier with a 10(12) ohm register. J Anal At Spectrom 25:1712–1716

    Article  CAS  Google Scholar 

  12. Cocherie A, Robert M (2007) Direct measurement of lead isotope ratios in low concentration environmental samples by MC-ICP-MS and multi-ion counting. Chem Geol 243:90–104

    Article  CAS  Google Scholar 

  13. Nelms SM, Quetel CR, Prohaska T, Vogl J, Taylor PDP (2001) Evaluation of detector dead time calculation models for ICP-MS. J Anal At Spectrom 16:333–338

    Article  CAS  Google Scholar 

  14. Galler P, Limbeck A, Uveges M, Prohaska T (2008) Automation and miniaturization of an on-line flow injection Sr/matrix separation method for accurate, high throughput determination of Sr isotope ratios by MC-ICP-MS. J Anal At Spectrom 23:1388–1391

    Article  CAS  Google Scholar 

  15. Paredes E, Goitom Asfaha D, Quétel CR (2013) Isotope ratio measurements by MC-ICPMS below 10 mL min−1 under continuous sample flow conditions. J Anal At Spectrom 28:320–326

    Article  CAS  Google Scholar 

  16. Paredes E, Goitom Asfaha D, Ponzevera E, Brach-Papa C, Van Bocxstaele M, Todoli JL, Quétel CR (2011) MC-ICP-MS isotope ratio measurements using an ultra-low flow sample introduction system. J Anal At Spectrom 26:1372–1379

    Article  CAS  Google Scholar 

  17. Van Heghe L, Engström E, Rodushkin I, Cloquet C, Vanhaecke F (2012) Isotopic analysis of the metabolically relevant transition metals Cu, Fe and Zn in human blood from vegetarians and omnivores using multi-collector ICP-mass spectrometry. J Anal At Spectrom 27:1327–1334

    Article  Google Scholar 

  18. Baxter DC, Rodushkin I, Engström E, Malinovsky D (2006) Revised exponential model for mass bias correction using an internal standard for isotope abundance ratio measurements by multi-collector inductively coupled plasma mass spectrometry. J Anal At Spectrom 21:427–430

    Article  CAS  Google Scholar 

  19. Cesbron A, Saussereau E, Mahieu L, Couland I, Guerbet M, Goullé JP (2013) Metallic profile of whole blood and plasma in a series of 106 healthy volunteers. J Anal Toxicol 37:401–405

    Article  CAS  Google Scholar 

  20. Burns J, Forsyth JS, Paterson CR (1993) Factors associated with variation in plasma copper levels in pre-term infants of very low birth weight. Eur J Pediatr 152:240–243

    Article  CAS  Google Scholar 

  21. Albarère F, Telouk P, Lamboux A, Jaouen K, Balter V (2011) Isotopic evidence of unaccounted for Fe and Cu erythropoietic pathways. Metallomics 3:926–933

    Article  Google Scholar 

  22. Jaouen K, Gilbert M, Lamboux A, Telouk P, Fourel F, Albarède F, Alekseev AN, Crubézy E, Balter V (2013) Is aging recorded in blood Cu and Zn isotope compositions? Metallomics 5:1016–1024

    Article  CAS  Google Scholar 

Download references

Acknowledgments

The Flemish Research Foundation (FWO-Vlaanderen) is acknowledged for financial support through Research Project G023014N. Marta Costas-Rodríguez thanks BOF-UGent for her postdoctoral grant. Prof. Dr. A. Verstraete (Department of Clinical Chemistry, Microbiology and Immunology, Ghent University) is acknowledged for providing us with whole blood samples.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Frank Vanhaecke.

Additional information

Marta Costas-Rodríguez and Lara Lobo contributed equally to this work.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Costas-Rodríguez, M., Lobo, L. & Vanhaecke, F. A novel approach to measure isotope ratios via multi-collector—inductively coupled plasma—mass spectrometry based on sample mixing with a non-enriched standard. Anal Bioanal Chem 406, 4393–4399 (2014). https://doi.org/10.1007/s00216-014-7837-1

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00216-014-7837-1

Keywords

Navigation