Abstract
Pharmacodynamic (PD) analysis requires accurate and precise quantification of enzyme activity targeted by anticancer agents in surrogate cells like peripheral blood mononuclear cells (PBMCs). Enzyme activity is normally reported per mass unit of protein input. However, high and fluctuating hemoglobin (Hb) contamination strongly influences the protein content of PBMC cytosolic lysate. We present the development and validation of a spectrophotometrical Hb quantification method to correct for this contamination. The applicability of Hb correction was demonstrated by determination of the dihydropyrimidine dehydrogenase enzyme activity in PBMC cytosolic lysates.
Similar content being viewed by others
References
Kummar S, Kinders R, Gutierrez ME, Rubinstein L, Parchment RE, Phillips LR, Ji J, Monks A, Low JA, Chen A, Murgo AJ, Collins J, Steinberg SM, Eliopoulos H, Giranda VL, Gordon G, Helman L, Wiltrout R, Tomaszewski JE, Doroshow JH (2009) J Clin Oncol 27:2705–2711
Burczynski ME, Twine NC, Dukart G, Marshall B, Hidalgo M, Stadler WM, Logan T, Dutcher J, Hudes G, Trepicchio WL, Strahs A, Immermann F, Slonim DK, Dorner AJ (2005) Clin Cancer Res 11:1181–1189
Boyum A (1968) Scand J Clin Lab Invest Suppl 97:77–89
Boyum A (1968) Scand J Clin Lab Invest Suppl 97:9–29
Olson BJ, Markwell J (2007) Curr Protoc Protein Sci Chapter 3:4.1–4.29
Ficoll-Paque™ PLUS product insert (2012) https://www.gelifesciences.com/gehcls_images/GELS/Related%20Content/Files/1314823637792/litdoc11003135AC_20110831231429.pdf
BD vacutainer® CPT product insert (2012) http://www.bd.com/vacutainer/pdfs/bd_cpt_VDP40104.pdf
Jansen RS, Rosing H, Schellens JH, Beijnen JH (2009) Anal Bioanal Chem 395:863–867
van Kuilenburg AB, van Lenthe H, Blom MJ, Mul EP, Van Gennip AH (1999) Br J Cancer 79:620–626
Vajpayee N, Graham SS, Bem S (2011) Henry's clinical diagnosis and management by laboratory methods chapter 30. Saunders, Irvine, pp 509–535
Weaver LK, Hintz-Goldstein KA, Pioli PA, Wardwell K, Qureshi N, Vogel SN, Guyre PM (2006) J Leukoc Biol 80:26–35
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Below is the link to the electronic supplementary material.
ESM 1
(PDF 74 kb)
Rights and permissions
About this article
Cite this article
Pluim, D., Jacobs, B.A.W., Krähenbühl, M.D. et al. Correction of peripheral blood mononuclear cell cytosolic protein for hemoglobin contamination. Anal Bioanal Chem 405, 2391–2395 (2013). https://doi.org/10.1007/s00216-012-6614-2
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-012-6614-2