Abstract
A trazodone-selective electrode for application in pharmaceutical quality control and urine analysis was developed. The electrode is based on incorporation of a trazodone-tetraphenylborate ion exchanger in a poly(vinyl chloride) membrane. The electrode showed a fast, stable and Nernstian response over a wide trazodone concentration range (5 × 10−5−1 × 10−2 M) with a mean slope of 59.3 ± 0.9 mV/dec of concentration, a mean detection limit of 1.8 × 10−5 ± 2.2 × 10−6 M, a wide working pH range (5–7.5) and a fast response time (less than 20 s). The electrode also showed good accuracy, repeatability, reproducibility and selectivity with respect to some inorganic and organic compounds, including the main trazodone metabolite. The electrode provided good analytical results in the determination of trazodone in pharmaceuticals and spiked urine samples; no extraction steps were necessary. Dissolution testing of trazodone tablets, in different conditions of pH and particle size, based on a direct potentiometric determination with the new selective electrode is presented as well.
Similar content being viewed by others
References
Ayad MM, Shalaby A, Abdellatef HE, Hosny MM (2003) Anal Bioanal Chem 376:710–714
Kumar RS, Manjunatha DH, Shaikh SMT, Seetharamappa J, Harikrishna K (2006) Chem Pharm Bull 54:968–971
Yang GJ, Liu P, Qu XL, Ming S, Wang CY, Qu QS, Hu XY, Leng ZZ (2007) Anal Lett 40:151–162
Carda-Broch S, Gil-Agustí MT, Monferrer-Pons LI, Esteve-Romero JS (2007) J Chromatogr A 1156:254–258
Stankova M, Ondra P, Kurka P (2007) Chem Listy 101:916–922
Cruz-Vera M, Lucena R, Cárdenas S, Valcarcel M (2008) Anal Bioanal Chem 391:1139–1145
Vanhoenacker G, De l’Escaille F, De Keukeleire D, Sandra P (2004) J Chromatogr B 799:323–330
El-Enany N, Belal F, Rizk MS (2002) J Pharm Biomed Anal 30:219
Khalil S (1999) Analyst 124:139–142
Suzuki H, Akimoto K, Nakagawa H, Sugimoto I (1989) J Pharm Sci 78:62–65
Khalil S, El-Ries MA (2002) J Pharm Biomed Anal 27:117–122
Cosofret VV, Buck RP (1993) Crit Rev Anal Chem 24:1–58
Vytras K (1989) J Pharm Biomed Anal 7:789–812
Hassan SSM, Mahmoud WH, Elmosallamy MAF, Almarzooqi MH (2005) J Pharm Biomed Anal 39:315–321
Ueda K, Yonemoto R, Komagoe K, Masuda K, Hanioka N, Narimatsu S, Katsu T (2006) Anal Chim Acta 565:36–41
Gupta VK, Sing AK, Gupta B (2007) Anal Bioanal Chem 389:2019–2028
Ortuño JA, Rodenas V, García MS, Albero MI, Sánchez-Pedreño C (2007) Sensors 7:400–409
Ensafi AA, Allafchian AR (2008) J Pharm Biomed Anal 47:802–806
United States Pharmacopeial Convention (2000) The United States pharmacopeia, 24th revision, Asian revision. United States Pharmacopeial Convention, Rockville
Moffat A, Jackson JV, Moss MS, Widdop B (1986) Clarke’s isolation and identification of drugs, 2nd edn. The Pharmaceutical Press, London
Kalgutkar AS, Henne KR, Lame ME, Vaz ADN, Collin C, Soglia JR, Zhao SX, Hop CECA (2008) Drug Metab Dispos 36:841–850
Acknowledgements
We gratefully acknowledge the Ministerio de Ciencia y Tecnología, Spain (project CTQ 2005-06977/BQU), and FEDER (Fondo Europeo de Desarrollo Regional) for financial support of this work.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
García, M.S., Ortuño, J., Albero, M.I. et al. Application of a trazodone-selective electrode to pharmaceutical quality control and urine analyses. Anal Bioanal Chem 394, 1563–1567 (2009). https://doi.org/10.1007/s00216-009-2699-7
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-009-2699-7