Abstract
Spectroradiometric measurements of reflectance and CIELAB hue-angle, were tested for K(I) determination using disposable optical sensors based on ion exchange mechanism. The linearisation of the sigmoidal response function, using a logistic regression, increases the linear range noticeably to 7.65 × 10−8–1.5 M and 1.22 × 10−7–1.5 M for CIELAB hue-angle and reflectance, respectively. The trueness of both procedures was demonstrated comparing it with results obtained by a DAD spectrophotometer used as a reference measurement procedure. The usefulness of the procedure was checked by analysing K(I) in different types of waters and beverages. Additionally, we studied the possible visual discrimination for the whole potassium range tested, obtaining the possibility of discriminating twelve groups of concentrations.
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00216-008-2552-4/MediaObjects/216_2008_2552_Fig1_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00216-008-2552-4/MediaObjects/216_2008_2552_Fig2_HTML.gif)
![](http://media.springernature.com/m312/springer-static/image/art%3A10.1007%2Fs00216-008-2552-4/MediaObjects/216_2008_2552_Fig3_HTML.gif)
Similar content being viewed by others
References
Capitán-Vallvey LF (2005) One-shot sensors. In: Grimes CA, Dickey EC, Pishko MV (eds) Encyclopedia of sensors. The Pennsylvania State University, Pennsylvania, USA
Hildebrand K, Von Döhren HH, Perrey H, Wehling K (1989) Transparent test strip system. US 4,824,640
Capitán-Vallvey LF, Arroyo-Guerrero E, Fernández-Ramos MD, Santoyo-González F (2005) Anal Chem 77:4459–4466
Eisinger RW, Khalil MH, Katz DH, Sargeant RB (1990) Lateral flow, non-bibulous membrane assay protocols. US 4,943,522.
Capitán-Vallvey LF, Al-Barbarawi OMA, Fernández-Ramos MD, Avidad-Castañeda R (2003) Talanta 60:247–255
Ballesta Claver J, Valencia Mirón MC, Capitán-Vallvey LF (2004) Anal Chim Acta 522:267–273
Leca BD, Verdier AM, Blum LJ (2001) Sens Actuators B B74:190–193
Ershova NI, Ivanov VM (2000) Anal Chim Acta 408:141–151
Suzuki Y, Suzuki K (2005) Springer Series on Chemical Sensors and Biosensors 3:343–365
Janzen MC, Ponder JB, Bailey DP, Ingison CK, Suslick KS (2006) Anal Chem 78:3591–3600
Lapresta-Fernández A, Capitán-Vallvey LF (2008) Sens Actuators B B134:694–701
Abbaspour A, Mehrgardi MA, Noori A, Kamyabi MA, Khalafi-Nezhad A, Soltani Rad MN (2006) Sens Actuators B 113:857–865
Capitán-Vallvey LF, Fernández-Ramos MD, Al Natsheh M (2003) Sens Actuators B 88:217–222
Orbe Paya I, Erenas M, Capitán-Vallvey LF (2007) Sens Actuators B 127:586–592
Morf WE, Seiler K, Rusterholz B, Simon W (1990) Anal Chem 62:738–742
CIE 15:2004 (2004) Colorimetry, (Technical Report) 3rd Edition, CIE Central Bureau, Vienna
CIE Publ.142-2001 (2001) Improvement to Industrial Colour-Difference Evaluation. CIE Central Bureau, Vienna
Melgosa M, Huertas R, Berns RS (2008) J Opt Soc Am A 25:1828–1834
Huertas R, Melgosa M, Martínez-Verdú F, Lapresta-Fernandez A, Fernández-Ramos MD, Capitán-Vallvey LF (2006) Argencolor 2004:45–51
Capitán-Vallvey LF, Lapresta-Fernández A, Fernández-Ramos MD, Cuadros-Rodríguez L (2006) Sens Actuators B 117:27–34
Acknowledgements
We acknowledge financial support from Ministerio de Educación y Ciencia, Dirección General de Enseñanza Superior (Spain) (Projects CTQ2005-09060-CO2-01 and FIS2007-64266 co-financed the last one with FEDER; and Junta de Andalucía, Proyecto de Excelencia P06-FQM-01467).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Lapresta-Fernández, A., Huertas, R., Melgosa, M. et al. Colourimetric characterisation of disposable optical sensors from spectroradiometric measurements. Anal Bioanal Chem 393, 1361–1366 (2009). https://doi.org/10.1007/s00216-008-2552-4
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-008-2552-4