Introduction

Soot particles are hazardous environmental pollutants that account for a major fraction of fine air particulate matter in urban areas. They can cause and enhance respiratory, cardiovascular, and allergic diseases, and they influence atmospheric chemistry, physics, and climate [13].

In compliance with present and future emission limits of diesel particulate matter (DPM), a wide range of particle trapping and exhaust treatment technologies have been introduced or are under development, e.g. ceramic diesel particulate filters (DPF) or novel particle traps and oxidation catalysts with open deposition structures [48]. These technologies generally require a regeneration method which efficiently oxidises and gasifies soot deposited in the filter or catalyst structures. Usually the regeneration is either based on discontinuous oxidation by O2 at temperatures higher than 700 K (regular heating intervals) or continuous oxidation at temperatures in the range of 500–700 K with NO2 as the main oxidant. Thus, the reaction between soot and NO2 is of high importance, because prevention of toxic or mutagenic reaction components is essential.

Chemical investigations of the oxidation process of carbon and soot using ozone or nitrogen dioxide have often been performed by spectroscopy (IR, DRIFTS) in order to detect oxygen-containing groups on the soot surface after oxidation [912], or to detect gaseous components formed during the reaction, e.g. HONO [13] or CO2 [14, 15] to evaluate the oxidation kinetics. Recently, the influence of the soot microstructure has been studied in detail [16, 17].

Soot consists mostly of carbon and is composed of agglomerated primary particles with diameters of 10–30 nm that comprise nanocrystalline [8, 1720] and amorphous domains. The amorphous domains are disordered mixtures of polycyclic aromatic hydrocarbons (PAH) and other organic and inorganic components [8, 18, 21, 22]. As a simplified view, these amorphous domains can be regarded as giant PAHs (e.g. coronene, C24H12 in Fig. 1a, and hexabenzocoronene (HBC), C42H18, in Fig. 1b), although the amorphous parts of soot are not expected to have the same planar structure as HBC. However, a recent publication showed that HBC is a good model for the amorphous part of diesel soot [8]. Therefore, with the oxidation of HBC by NO2 one is able to mimic the oxidation of diesel soot with a molecularly defined substance. This allows examination of the oxidation products with a well-established chemical analysis method.

Fig. 1
figure 1

Structural formulae of PAHs oxidised in this study: (a) coronene (C24H12), (b) hexabenzocoronene, HBC (C42H18)

Liquid chromatography-mass spectrometry (LC-MS) coupled with atmospheric pressure ionisation (API) is known to be a strong tool for analysis of several classes of organic pollutant [23, 24]. The API sources “atmospheric pressure photoionization” (APPI) and “atmospheric pressure chemical ionization” (APCI) are very well suited to the ionisation of small uncharged aromatic molecules separated by LC [25]. LC-APCI-MS, for instance, was successfully used to determine high-molecular-mass polycyclic aromatic hydrocarbons from environmental samples [26]. Letzel et al. described the suitability of APCI-MS for analysis of semi-polar oxidation products (phenols, quinones) from the heterogeneous reaction of benzo[a]pyrene, water, and ozone [27, 28]. Later, an effective LC-APCI-MS method was published for the characterization of nitrated PAHs on aerosols [29].

However, to our present knowledge there have been no LC-API-MS investigations to research the oxidation of large, symmetric, and stable PAHs with NO2 at elevated temperatures.

In this work we present a simple approach to oxidize the large PAHs coronene and hexabenzocoronene with NO2 and O2 at high temperatures. The aim of this study was to vary strongly the oxidation conditions (temperature, NO2, and O2 content) and to study the effect of this on the oxidised species detected in subsequent analysis. An established pre-separation step using solid-phase extraction [27, 28] was adapted with fast LC-MS for fingerprint analysis of partially oxidized PAHs. This study helps to close the gap between theoretical calculations [30] and the limited amount of experimental data present in the literature today.

Experimental

Sample preparation

Coronene (0.5 mg; 99.8%; PAH Institute, Dr Schmidt, Greifenberg, Germany) was spread on a quartz-fibre filter (4.5 cm, QF-10, Macherey Nagel, Düren, Germany) by dropping a cyclohexane solution on the filter and evaporating the solvent.

HBC was obtained from the research group of Professor Müllen, Max-Planck Institute for Polymer Research, Mainz, Germany. Ultrafine HBC particles (1.0 mg), produced by sublimation under a stream of nitrogen [31], were collected on a quartz-fibre filter.

Oxidation procedure

An appropriate quartz-glass apparatus was manufactured to oxidise the PAHs at elevated temperatures and stop the reaction immediately by cooling from outside with liquid nitrogen (Fig. 2). The reaction gases (nitrogen 5.0 (i.e. 99.999% purity), oxygen 3.5 (i.e. ≥99.95% purity), and nitrogen dioxide (1010 ppm NO2 in nitrogen 5.0)) were supplied in gas bottles (Messer Griesheim, Krefeld, Germany) and the gas flows were controlled by rotameters (Rota Yokogawa, Ratingen, Germany). Nitrogen and oxygen were moistened by streaming through a water-filled washing bottle using a glass frit. By varying the three gas flows (overall flow 4 L min−1) two different NO2 concentrations (250 and 500 ppm) and three different O2 concentrations (0, 50, and 75%) could be achieved.

Fig. 2
figure 2

Schematic representation of the setup used for oxidation of large PAH. Qt: Quartz tube filled with quartz beads, externally heated by Ht. Ht: Quartz tube wrapped by heating coil. Ut: U-like reaction tube, isolated with glass wool. Ft: Filter with large PAH. Hc: Heating control unit. Rm: Rotameter. Hu: Humidifier

The gas mixture was heated by flowing through the quartz-glass tube, Qt (60 cm, d = 1.3 cm), containing quartz beads to optimise heat transfer. Temperature regulation was performed by use of a surrounding heating tube, Ht, supplied by a control unit, Hc (HT 52, Hillesheim, Germany). In the subsequently connected U-tube, Ut (10 cm × 3.5 cm), isolated by glass wool, the hot gases reacted with the PAH-loaded filter. The temperature at the position of the filter can easily be regulated by varying the temperature of the heating tube (ht). The temperature at the filter was determined in previous test experiments using a thermocouple and pure nitrogen. All parts were joined by glass flanges or hose connections (Tygon, Saint-Gobain, Charny, France).

After oxidising the large PAHs (2 h for coronene, 1 h for HBC samples) the reaction was stopped immediately by changing the gas mixture to pure nitrogen and simultaneously cooling the U-tube with liquid nitrogen, using an appropriate Dewar flask.

Extraction and pre-separation

The remaining PAH and oxidation products were extracted from the filters, pre-separated (using solid-phase extraction) and concentrated by applying a method developed earlier [27, 28]. The filters were extracted in 4 mL of a 1:1:1 mixture of toluene (LiChrosolv, Merck, Darmstadt, Germany), dichloromethane (extra pure, Merck), and methanol (HPLC-gradient grade, Merck) in an ultrasonic bath (Sonorex, Moerfelden, Germany) for 15 min. After the filter was removed, the solvent was evaporated to dryness, and subsequently the residue was dissolved in 1 mL toluene and applied to a silica column (length 120 mm, I.D. 5 mm; filled with 0.8 g silica (silica gel 60, purest, Merck)). Elution was carried out consecutively with 5 mL toluene, 15 mL dichloromethane, and 5 mL methanol. Each solution was collected, filtered (0.2-μm PTFE, 4-mm syringe filter, Alltech, Norderstedt, Germany), evaporated to dryness under a nitrogen stream, and resolved in 75 μL MeOH. DCM and MeOH fractions were subjected to HPLC separation.

LC-API-MS

An Agilent micro HPLC system (series 1100, Waldbronn, Germany) was used in connection with a single-quadrupole mass spectrometer (MSD SL, Waldbronn, Germany). The apparatus consisted of a quaternary capillary pump (G1376A), a degasser unit (G1379A), an auto sampler (G1377A), and a column in a thermostat (G1316A) set to 40°C. The mass-selective detector (G1956B) was connected by an APCI interface (G1947A) or an APPI interface (G1971A). HPLC, ionization, and the mass spectrometric detector were controlled and data were analyzed using ChemStation software (Rev. B.01.01, Agilent, Waldbronn, Germany).

The chromatographic separation was performed with a Nucleosil 120-7C6H5 column (250 mm × 4 mm I.D., 7 μm spherical, not endcapped; CS, Langerwehe, Germany) with MeOH-H2O as the mobile phase at a flow rate of 500 μL min−1 and an injection volume of 5 μL. The mobile phase was MeOH-H2O, 80:20 (v/v) at the beginning of a chromatographic run and increased within 2 min to 100% MeOH to achieve rapid elution of the oxidation products. This was held for 54 min to elute also the strongly hydrophobic compounds. Finally, the mobile phase composition was reset to initial conditions within 4 min.

Note that during analysis of the samples the pressure in the HPLC system increased, obviously caused by the high contamination potential of the samples, even after filtration. One should use pre-columns if a larger number of samples are to be analysed.

The mass spectrometric interface settings were analogous to the APCI and APPI conditions published previously [25]: 350 °C drying gas temperature, 360 L h−1 drying gas flow, 4.13 × 105 Pa nebulizer gas pressure (gauge pressure), and 225 °C (APCI) or 275 °C (APPI) vaporizer temperature.

Mass spectrometric detection was performed in positive-ion mode. For detection a capillary potential of 2500 V (APCI) or 1500 V (APPI) was used, a “fragmentor” potential of 100 V (APCI) or 200 V (APPI), and for APCI a corona current of 7 μA. The scan range was set to 250–400 m/z (for the coronene samples) and 350–650 m/z (for the HBC samples).

Results and discussion

Oxidation of giant PAHs

Table 1 summarizes the reaction conditions achieved in the experimental setup and applied to coronene and HBC samples for intensive oxidation with oxygen and NO2. The three samples of HBC at lower temperature (H2–H4) were performed consecutively due to the low reactivity of HBC, meaning the extracted filter of the previous experiment with probably pre-oxidised (but still insoluble) HBC was again exposed to the reaction gases.

Table 1 Reaction conditions for the moistened coronene (C1–C3) and the HBC (H1–H4) samples

The gas mixture consisted of moistened nitrogen together with different ratios of NO2 and O2. For coronene sample C1, NO2 was not the only reactive species, but also HNO2 and HNO3 which are formed in the wet environment due to disproportionation of NO2. The temperature for sample C2 was the same as for C1 (150 °C), however 50% O2 was present. This leads to a higher content of HNO3 in the reaction gas due to oxidation of HNO2. The oxidation effect on the PAHs will be stronger since HNO3 has greater oxidation strength than HNO2 and a large amount of O2 is present. The reaction environment of sample C3 may be less harsh compared with C2 due to the lower reaction temperature (22 °C).

The reaction conditions for HBC varied between 22 and 350 °C, 250 and 500 ppm NO2, and 0 and 75% O2 to achieve strongly different oxidation states.

Exposure of the large PAHs-loaded filter to reaction gas should, in principle, lead to physisorption and chemisorption of reactive species (NO2, HNO3), and subsequent degradation of the PAHs by formation of different oxygen-containing groups (e.g. carbocyclic acids, lactones, R-NO2 and R-ONO functionalities). During reaction these intermediate products will decompose, either thermally or chemically by oxidising species, releasing CO2, NO, or CO. At elevated temperature thermally induced desorption of oxidised fragments will also occur.

Increasing the reaction temperature therefore has two effects. First, the oxidation will be much faster, which means that a larger fraction of the PAH is converted into an oxidised form. Second, however, this can also lead to a higher amount of volatile species which may not remain on the filter for further analysis. However, due to the large aromatic backbone and the applied cooling by liquid nitrogen, the amount of oxidised species on the filter should remain high.

Analysis of giant PAH oxidation products

Pre-separation by solid-phase-extraction

As proven earlier for benzo[a]pyrene samples, the toluene extract contains unreacted PAH [27, 28]. Due to the main presence of polar oxidation products in DCM and MeOH fractions, only these were subjected to HPLC analysis. The great majority of compounds formed during oxidation of coronene were found in the DCM fraction, thus only the DCM results will be discussed. The extraction of oxidized HBC led to oxidation compounds in both the DCM and the HBC solution.

Fast LC-API-MS

The applied column and mobile phase was not adopted to obtain an appropriate analytical separation of the oxidation products by reversed-phase LC. In fact, it was used to have slight retention on the chromatographic column for the compounds of interest. Thus, they can be separated from ionic compounds and from non-oxidized hydrophobic PAH. The former compounds elute from the column without being retarded and the latter are retained very strongly on the reversed-phase column. Both classes of compound may show high signal-suppressing effects in mass spectrometric detection due to neutralization, clustering, and/or adduct formation effects similar to electrospray ionization [3234]. Thus it is proposed to separate them by LC at least some seconds from the molecules of interest.

The high methanol content in the first time section caused fast, but broad elution of compounds, because efficient retention of various compounds was absent. The two chromatographic peaks elute with a retention width of a few minutes, as can be seen in the total ion chromatogram (TIC) in Fig. 3a. The extraction of single mass traces displayed as extracted ion chromatograms (EICs) discloses a rather more detailed view of the behaviour of the oxidation products (e.g. Fig. 3b). Please note that the adopted separation should be applied for comparison with our earlier studies [27, 28], but should not illustrate an optimized separation method. Furthermore, the long time at high methanol content may ensure major elution of non-reacted PAHs.

Fig. 3
figure 3

Chromatograms obtained from the DCM fraction of the coronene sample C2. (a) total-ion chromatogram (TIC, m/z 250–400); (b) normalized extracted-ion chromatograms (EIC) for prominent masses of sample C2 (DCM fraction)

Several compounds shown in the EICs of Fig. 3b have been ionized by one of the two commercially available ionization techniques for “semipolar” molecules, APCI and APPI. Generally, oxidized PAHs are rarely ionised in solution and have therefore to become charged in the transfer region of the mass spectrometer. At the beginning of the study a test was performed to determine whether the source properties (section LC-API-MS) for oxidized species of the large PAHs were similar to those for partially oxidized PAHs up to five condensed aromatic rings, as published previously [25]. Comparison for positive-ion mode showed similar ionization behaviour and signal efficiency for both interfaces (data not presented). Please note in the forthcoming results we describe the mass spectrometric detection solely with APCI in positive-ion mode. However, one has to keep in mind, that APPI gave exactly the same results, i.e. solely results with minimum two independent experiments were interpreted in the forthcoming paragraphs.

Reaction of coronene

Again, Fig. 3 presents the (a) TIC and (b) EICs of the DCM fraction obtained from sample C2. The EICs originated from the masses contributing to the TIC; typical mass spectra of this sample are shown in Fig. 4. It can be clearly seen that different elution maxima (Fig. 3b) and different peak shapes of the EICs result from different molecules. The extracted ion chromatograms for the six most prominent masses in Table 2 (m/z 256, 279, 280, 282, 338, and 391) are depicted in Fig. 3b by increasing retention time. Most dominating masses indicate that every m/z value belongs to a distinct group of oxidation products. For instance, the molecule with the highest intensity in C2 has m/z 282; it is shown in Fig. 5a with its proposed chemical structure. Most of the compounds in Table 2 contain an odd number of nitrogen atoms, due to the even molecular mass of [M+H]+ ions, e.g. m/z 282, 338, and 352 (Figs. 5a,b, and c, respectively). Protonated molecules without nitrogen or an even number of nitrogen in contrast have an odd m/z in the mass spectrum (e.g. the compound in Fig. 5d).

Fig. 4
figure 4

Mass spectra of coronene sample C2 (DCM fraction) for two different TIC integration regions (Fig. 3a): (a) t = 3.2–5.3 min, (b) t = 5.3–7.5 min

Fig. 5
figure 5

Proposed structures of four coronene nitration/oxidation products that were tentatively identified by fingerprint LC-API-MS; in several cases, other isomers are equally probable

Table 2 EIC retention time and peak integral of prominent masses of coronene samples (DCM fraction)

Some m/z values exhibit two separated peaks, e.g. m/z 256. This can be probably attributed to isomers with different retention times due to intra-molecular hydrogen bonding of contained functional groups [25]. Furthermore, the same procedure of extracting the most intense mass signals was repeated for the two other coronene DCM solutions (C1 and C3). Table 2 summarizes the six to nine most prominent m/z values with retention times and integrated peak area (EIC) of all three DCM solutions. The different oxidation conditions are reflected in the varying intensities of the oxidation products. For samples C1 and C3, m/z 338 (Fig. 5b) is the dominating mass, the relative intensity of the other m/z values being smaller than 10%. When oxygen is added (C2 and C3) and at elevated oxidation temperature (C2), the intensity of m/z 391 increases, whereas at room temperature (C3) the intensity of m/z 391 is low. Additionally, the m/z value 310 appears, being the second most intense peak for the room-temperature oxidized sample C3. Furthermore, another consequence of the O2 addition at high temperature (C2) is the small absolute amount of detected products in the sample. This is obviously due to the harsher oxidation conditions, leading to the formation of smaller, more volatile organic compounds or even species like CO or CO2, which are released from the filter. On the other hand the room-temperature sample C3 contains the highest variety of oxidized compounds in the mass spectrometric range 200–400 Da and the highest compound intensities. This could be explained by the lower oxidation efficiency at room temperature and, therefore, more non-volatile compounds. The masses 256, 279, 280, and 282 are present in all samples with similar intensity indicating that the compounds can be formed independently from oxygen availability and elevated temperature.

Reaction of HBC

The pre-separation showed different effects on the HBC samples compared with the coronene samples. Oxidation products can be found in both the DCM and the MeOH fractions.

Figure 6a shows a typical TIC for H2, clearly reflecting the higher hydrophobicity of some products, but also showing signals that are comparable with coronene products. Again there are several compounds behind each signal as can be seen in the four mass spectra of Fig. 6b. The m/z values obtained are also independent of each other, as checked for the six most prominent peaks in the EICs (data not shown).

Fig. 6
figure 6

(a) TIC of DCM fraction of sample H2. (b) For peaks 2–5 the MS spectra are given

Table 3 presents the most intense m/z values from the TIC of several DCM and MeOH solutions by increasing ion masses. Compounds with m/z > 522 (e.g. 611, 563, 637) appeared, and may be oxygen-containing HBC fragments, or larger molecules, formed during the oxidation process. The masses and amounts of oxidized compounds is different for all HBC samples. However, m/z 352 and m/z 391 could also be found in most samples. Generally, for this purpose also, very high temperatures led to compounds with high polarity and lower molecular masses as in sample H1. Elevated temperatures led to a mixture of several compounds (H2). Finally, the addition of oxygen (H3 and H4) led to a more complicated picture, however the degradation is less effective than at 350 °C (H1).

Table 3 EIC retention time and peak integral for the most prominent m/z values (max. 6) of DCM and MeOH fractions of HBC samples

Last, but not least, some of the derived mass spectra showed very interesting patterns which should be mentioned. The MS signal behind the first chromatographic signal of the MeOH fraction of sample H2 (Fig. 7a) offers two sets of masses which are separated by m/z 44. This could be due to a set of molecules which differ only in their number of carboxyl groups.

Fig. 7
figure 7

(a) Mass spectrum (t = 3.2–4.1 min) of sample H2, MeOH fraction. Two series of m/z values, separated by m/z 44 are visible. (b) MS spectrum (t = 3.3–3.7 min) of sample H3, DCM fraction. This shows two series of peaks, separated by m/z 14

In the MS signal of the first chromatographic signal of the DCM fraction of sample H3, m/z 551 and 577 are surrounded by two series of peaks, separated by m/z 14, which may be due to CH2. This could be explained by a class of substances which only differ in the length of one or more alkane groups. The pattern was only visible in sample H3, where 50% O2 was added during the reaction. The pattern may be a representative of different stages of the oxidation process of the parent molecule HBC. This highlights the excellent application of mass spectrometry although very complex mixtures have to be analysed. Further research should be performed to obtain an overall picture of oxidation mechanism.

Conclusion

In this publication we presented an easy method for oxidation of large PAHs at elevated temperatures. The oxidation conditions (temperature, exposure time, and gas composition and concentrations) could easily be varied and the cooling of the PAH loaded filter with liquid nitrogen quickly stops the reaction.

Rapid analysis of the oxidation products with SPE and the LC-API-MS compound fingerprint subsequently revealed that in most of the samples a few compounds with specific m/z values are present as a stable sink. Whereas coronene oxidation products mainly elute in this study with dichloromethane from the SPE columns, oxidized HBC compounds elute in both the dichloromethane and the methanol fractions. However, a collection foam must be added after the filter to enable analysis of volatile compounds in future experiments.

Dominating compounds of m/z 282 and m/z 256 resemble stable oxidation products originating from benzo[a]pyrene (e.g. m/z 283, and m/z 257) in previous research. m/z 391 was a major product of every HBC-sample whereas m/z 338 is the predominant reaction product found in two of the coronene samples.

For identification of these compounds further MS-MS experiments are needed, or a time-of-flight (ToF) mass spectrometer. Accurate mass with high resolution ToF leads to an elemental formula and tandem mass spectrometry to structure identification by compound fragmentation.

The fact that only a few molecules (or isomers) could be found in most of the samples shows that using a well defined soot model compound like HBC is promising for further investigations of the oxidation process.

The precise pathway of degradation of large PAH by oxidation and nitration may be clarified by LC-APCI-MS. However, further experiments are necessary with defined conditions, smaller steps in changes of conditions, and mass spectrometers of high accuracy and sensitivity.