Evaluation of error sources in a gravimetric technique for preparation of a reference gas mixture (carbon dioxide in synthetic air)

  • Original Paper
  • Published:
Analytical and Bioanalytical Chemistry Aims and scope Submit manuscript

Abstract

One method of preparing a primary reference gas mixture is the gravimetric blending method. Uncertainty of a few mg in mass measurements is unavoidable when preparing reference gas mixtures under current laboratory conditions with our facilities, equipment, and materials. There are many sources of errors when using this method. In this study, several sources of errors were re-evaluated for our process for preparation of carbon dioxide in synthetic air. As a consequence of the re-evaluation, it was found that some sources of errors had significant effects on gravimetric concentrations of the gas mixtures. These sources are: (1) different masses of the reference cylinder and sample cylinder (an error in the readings of the electronic mass comparator), (2) leakage of the inner gas from valves of the cylinders, and (3) cooling of the gas cylinder caused by filling with high-pressure liquefied carbon dioxide gas. When the mass measurements were performed under uncontrolled conditions, the errors due to sources (1), (2), and (3) were as high as 20 mg, 24 mg, and 13 mg, respectively. In this paper, the detailed results from re-evaluation of these sources of errors are discussed.

Evaluation of the source of error (1)

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. WMO (2005) WDCGG DATA SUMMARY, WDCGG No.29, GAW DATA, Volume IV, Greenhouse gases and other atmospheric gases. Japan Meteorological Agency in Co-operation with the World Meteorological Organization

  2. van der Veen AMH et al (2007) Metrologia 44, Tech Suppl 08003

  3. International Standard Organisation (2001) ISO 6142 2nd edition, Gas analysis—preparation of calibration gas mixtures—gravimetric methods. International Organization for Standardization, Geneva

  4. Matsumoto N, Watanabe T, Kato K (2005) Accred Qual Assur 10:382–385

    Article  Google Scholar 

  5. Matsumoto N, Watanabe T, Maruyama M, Horimoto H, Maeda T, Kato K (2004) Metrologia 41:178–188

    Article  Google Scholar 

  6. Milton MJT, Woods PT, Holland PE (2002) Metrologia 39:97–99

    Article  Google Scholar 

  7. Alink A, van der Veen AMH (2001) Metrologia 37:641–650

    Article  Google Scholar 

Download references

Acknowledgement

We would like to thank the Japanese manufacturers for their cooperation during these trials; they provided an invaluable service for improvement of the quality of the cylinders and valves used in this study.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Nobuhiro Matsumoto.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Matsumoto, N., Shimosaka, T., Watanabe, T. et al. Evaluation of error sources in a gravimetric technique for preparation of a reference gas mixture (carbon dioxide in synthetic air). Anal Bioanal Chem 391, 2061–2069 (2008). https://doi.org/10.1007/s00216-008-2107-8

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00216-008-2107-8

Keywords

Navigation