Skip to main content
Log in

Instrumental modification intended to save time, and volumes of sample and reagent solutions, in the atomic fluorescence spectrometric determination of mercury

  • Technical Note
  • Published:
Analytical and Bioanalytical Chemistry Aims and scope Submit manuscript

Abstract

Use of small membrane pumps, instead of peristaltic pumps, to introduce sample and reagent solutions into the spectrometer has several advantages in atomic fluorescence spectrometric determination of mercury. This simple modification results in a substantial saving in the time required for the measurements and so 90% of reagent solution volumes and 95% of sample solution volumes are saved, with a consequent decrease in the volume of waste generated. The sampling frequency is almost tripled, with no deterioration in sensitivity, which is similar to that obtained by use of peristaltic pumps. The relative standard deviation for ten consecutive measurements of a 1 μg L−1 mercury solution was approximately 2%.

Small membrane pumps for the atomic fluorescene spectro metric determination of mercury

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Reis BF, Ródenas-Torralba E, Sancenón-Buleo J, Morales-Rubio A, de la Guardia M (2002) J Anal Atom Spectrom 17:537–540

    Article  CAS  Google Scholar 

  2. Reis BF, Ródenas-Torralba E, Sancenón-Buleo J, Morales-Rubio A, de la Guardia M (2003) Talanta 60:809–819

    Article  CAS  Google Scholar 

  3. Cava-Montesinos P, Ródenas-Torralba E, Morales-Rubio A, Cervera ML, de la Guardia M (2004) Anal Chim Acta 506:145–153

    Article  CAS  Google Scholar 

  4. López-García I, Ruíz-Alcaraz I, Hernández-Córdoba M (2006) Spectrochim Acta B 61:368–372

    Article  Google Scholar 

  5. Lapa RAS, Lima JLFC, Reis BF, Santos JLM, Zagatto EAG (2002) Anal Chim Acta 466:125–132

    Article  CAS  Google Scholar 

Download references

Acknowledgement

The authors are grateful to the Spanish MEC (Project CTQ2006-08037/BQU) and to Fundación Séneca (CARM, Spain) for financial support. M.L. García-Lorenzo also acknowledges a fellowship from Fundación Séneca.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Manuel Hernández-Córdoba.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pérez-Sirvent, C., Martínez-Sánchez, M.J., García-Lorenzo, M. et al. Instrumental modification intended to save time, and volumes of sample and reagent solutions, in the atomic fluorescence spectrometric determination of mercury. Anal Bioanal Chem 388, 495–498 (2007). https://doi.org/10.1007/s00216-007-1216-0

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00216-007-1216-0

Keywords

Navigation