CM Conducted EMI mitigation in flyback PFC converter

  • Original Paper
  • Published:
Electrical Engineering Aims and scope Submit manuscript

Abstract

The switched mode power supplies offer many advantages in power conversion. But they offer low power factor and generate electromagnetic interference (EMI). The low power factor can be improved by a front-end power factor correction (PFC) unit. However, they also generate EMI in both differential mode and common mode (CM). The interwinding capacitance of the transformer and parasitic capacitance between the heat sink and ground are major contributors to CM noise. The traditional method to minimize the CM noise by using a line filter consists of CM choke and Y capacitor. But, CM noise causes leakage current to flow to the ground through the Y capacitor. This leakage current has to be restricted as per the standards for commercially used equipment and medical instruments. The technique proposed here reduces the values of Y capacitor thereby reducing the leakage current. This can be reduced by minimizing the predominant parasitic capacitances of the HF transformer used in the PFC converter. This paper presents a technique for reducing these parasitic capacitances by incorporating an additional parasitic capacitance noise cancellation winding (PCW). A flyback transformer winding capacitance model depicting the parasitic capacitances is considered, and a novel method to determine this parasitic capacitance is presented. Using this model, the CM Conducted EMI in a flyback PFC is determined by simulation and experimentation. These simulation and experimentation results are used to design an EMI line filter to reduce the Conducted CM noise to complaint levels. The value of Y capacitor now is reduced due to the addition of PCW thereby reducing the size and cost of the filter. This technique has been validated experimentally on a 30-W power factor correction flyback converter working in critical conduction mode.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18

Similar content being viewed by others

References

  1. Ashritha M, Sudheer ML (2016) Low conducted EMI in NUPF converters. In: 2016 international conference on electromagnetic interference & compatibility (INCEMIC). Bangalore, pp 1–4

  2. Ashritha M, Sudheer ML (2017) Mitigation of CM conducted EMI IN SMPS. In: 2017 IEEE workshop on power electronics and power quality applications (PEPQA). Bogota, pp 1–6

  3. Adragna C, STMicroelectronics design equations of high-power-factor Flyback converter based on the L6561. www.stmicroelectronics.com

  4. Adragna C, Gattavari G, STMicroelectronics Flyback converters with the L6561 PFC controller. www.stmicroelectronics.com

  5. Paul CR (1992) Introduction to electromagnetic compatibility. Wiley, New York

    Google Scholar 

  6. Bai Y, Yang X, Zhang D, Li X, Chen W, Hu W (2017) Conducted EMI mitigation schemes in isolated switching-mode power supply without the need of a Y-capacitor. IEEE Trans Pow Electron 32(4):2687–2703

    Google Scholar 

  7. Biela J, Johann W (2008) Using transformer parasitics for resonant converters—a review of the calculation of the stray capacitance of transformers. IEEE Trans Ind Appl 44(1):223–233

    Google Scholar 

  8. Lu Hai Yan, Zhu Jian Guo, Hui S Y Ron (2003) Experimental determination of stray capacitances in high frequency transformers. IEEE Trans Pow Electron 18(5):1105–1112

    Google Scholar 

  9. Cochrane D, Chen DY, Boroyevic D (2003) Passive cancellation of common-mode noise in power electronics circuits. IEEE Trans Pow Electron 18(3):756–763

    Google Scholar 

  10. Chan YP, Pong BMH, Poon NK, Liu JCP (2012) Common-mode noise cancellation in switching-mode power supplies using an equipotential transformer modeling technique. IEEE Trans Electromagn Compat 54(3):594–602

    Google Scholar 

  11. Chan YP, Pong BMH, Poon NK, Liu JCP (2014) Common-mode noise cancellation by an antiphase winding in multilayer isolated planar transformer. IEEE Trans Electromagn Compat 56(1):67–73

    Google Scholar 

  12. Chu Y, Wang S (2015) A generalized common-mode current cancelation approach for power converters. IEEE Trans Ind Electron 62(7):4130–4140

    Google Scholar 

  13. Maniktala Sanjaya (2003) Fixing EMI across the board, principal engineer, power management group. National Semiconductor Corp, Santa Clara

    Google Scholar 

  14. Shoyama M, Li Ge, Ninomiya T (2003) Balanced switching converter to reduce common-mode conducted noise. IEEE Trans Ind Electron 50(6):1095–1099

    Google Scholar 

  15. Ashritha M, Sudheer ML (2018) CM Noise cancellation in near unity power factor converter. In: 2018 15th international conference on electromagnetic interference & compatibility (INCEMIC). Bengaluru, India, pp 1–4

  16. Massarini A, Kazimierezuk MK (1997) Self-capacitance of inductors. IEEE Trans Pow Electron 12(4):671–676

    Google Scholar 

  17. Harada K, Ninomiya T, Kakihara H (1981) Effects of stray capacitances between transformer windings on the noise characteristics in switching power converters. In: 1981 IEEE power electronics specialists conference. Boulder, Colorado, USA, pp 112–123

  18. Li Y, Zhang H, Wang S, Sheng H, Chng CP, Lakshmikanthan S (2018) Investigating switching transformers for common mode EMI reduction to remove common mode EMI filters and Y-capacitors in Flyback converters. IEEE J Emerg Sel Top Pow Electron 6(4):2287–2301

    Google Scholar 

  19. Cogitore B, Keradec JP, Barbaroux J (1994) The two-winding transformer: an experimental method to obtain a wide frequency range equivalent circuit. IEEE Trans Instruct Meas 43(2):364–371

    Google Scholar 

  20. 3R Enterprises for the design and manufacturing of Transformers and Coils used for SMPS. http://3re.co.in/

Download references

Acknowledgements

This work made use of Impedance analyser; the authors of this work appreciate the help of Dr. Basu from the IISc Department of Electrical and Electronics. This work needed a special setup for full compliance of Conducted EMI which was carried out in Electronics Test and Development Centre (ETDC), Department of Electronics and Information Technology, Ministry of Communication and IT, Govt. of India—STQC Bangalore. The authors of this work appreciate the help of Dr. Navin Chandra Joshy and Dr. Mandal from ETDC.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Ashritha.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ashritha, M., Sudheer, M.L. CM Conducted EMI mitigation in flyback PFC converter. Electr Eng 102, 563–571 (2020). https://doi.org/10.1007/s00202-019-00890-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00202-019-00890-x

Keywords

Navigation