Abstract
In high-voltage systems partial discharges (PD) may occur due to the degradation of insulation materials in addition to different scenarios such as material properties, construction, setup and operation conditions. Especially for a power transformer, the degradation of inner insulation may prevent regular operation and hence cause failure. In a long time period even low-level PD activity may cause degradation on the insulator. If the deterioration caused by the PD is detected in an early phase, potential damage may be prevented. Due to the complex and close structure of power transformers and other high-voltage systems, it is not easy to estimate the exact location of a PD. This study proposes a novel approach to detect and analyze an artificial PD in a laboratory room setup, which is especially designed for simulation of possible PD source in a large scale structure such as power transformer. Electromagnetic (EM) PD sensors are commonly used to detect electromagnetic pulses emitted from PD sources. In this work, the time differences of arrivals (TDOA) which are obtained from PD signals are subjected to multilateration technique to estimate the exact location. A novel energy level method is introduced to overcome correct TDOA extraction problem. Cramer–Rao bound (CRB) is used for calculation of the minimum achievable estimation error of proposed method. In order to display the accuracy of location estimation, CRB and the mean square error graphics of the estimated location parameters are given for the comparison.
Similar content being viewed by others
References
Lupò G, Petrarca C, Egiziano L, Tucci V, Vitelli M (1998) Partial discharge testing on resin insulated voltage transformers. Electr Eng 81(2):89–97
Guillen D, Idarraga-Ospina G, Mombello E (2014) Partial discharge location in power transformer windings using the wavelet Laplace function. Electr Power Syst Res 111:71–77
EN60270, B. S. IEC60270:2000 (2000) High voltage test techniques–partial discharge measurements. BSI copyright. ISBN 0 580 38138 2
Haddad A, Warne D (2007) Advances in high voltage engineering. The Institution of Engineering and Technology, London
Tenbohlen S, Denissov D, Hoek SM, Markalous SM (2008) Partial discharge measurement in the ultra high frequency (UHF) range. IEEE Trans Dielectr Electr Insul 15(6):1544–1552
Naderi MS, Blackburn TR, Phung BT, Naderi MS, Nasiri A (2008) Application of wavelet analysis to the determination of partial discharge location in multiple-\(\alpha \) transformer windings. Electr Power Syst Res 78(2):202–208
Jeyabalan V, Usa S (2009) Frequency domain correlation technique for PD location in transformer windings. IEEE Trans Dielectr Electr Insul 4:1160–1167
Nafar M, Niknam T, Gheisari A (2011) Using correlation coefficients for locating partial discharge in power transformer. Electr Power Energy Syst 33:493–499
Wang ZD, Hettiwatte SN, Crossley PA (2005) A measurements based discharge location algorithm for plain disc winding power transformers. IEEE Trans Dielectr Electr Insul 12(3):416–422
Judd MD, Farish O, Hampton BF (1996) The excitation of UHF signals by partial discharges in GIS. IEEE Trans Dielectr Electr Insul 3(2):213–228
Cleary GP, Judd MD (2002) An investigation of discharges in oil insulation using UHF PD detection. In: IEEE 14th international conference on dielectric liquids, pp 341–344
Judd MD, Yang L, Hunter IBB (2005) Partial discharge monitoring for power transformers using UHF sensors part 1: sensors and signal interpretation. IEEE Electr Insul Mag 21(2):5–14
Pinpart T, Judd MD (2009) Experimental comparison of UHF sensor types for PD location applications. In: IEEE electrical insulation conference, pp 26–30
Gulnihar K, Cayci H, Ugur M (2013) Design of electromagnetic partial discharge sensors for power transformers. In: 18th international symposium on high voltage engineering (ISH2013), Seoul Korea, pp 832–836
Dvorkind TG, Gannot S (2005) Time difference of arrival estimation of speech source in a noisy and reverberant environment. Signal Process 85(1):177–204
Chan YT, Ho KC (1994) A simple and efficient estimator for hyperbolic location. IEEE Trans Signal Process 42(8):1905–1915
Stoica P, Nehorai A (1989) MUSIC maximum likelihood and Cramer–Rao bound. IEEE Trans Acoust Speech 37(5):720–741
Stoica P, Nehorai A (1990) MUSIC maximum likelihood and Cramer–Rao bound: further results and comparisons. IEEE Trans Acoust Speech 37(5):2140–2150
Mcwhorter T, Scharf LL (1993) Cramer–Rao bounds for deterministic modal analysis. IEEE Trans Signal Process 41(5):1847–1864
Chen JC, Hudson RE, Yao K (2002) Maximum-likelihood source localization and unknown sensor location estimation for wideband signals in the near-field. IEEE Trans Signal Process 50(8):1843–1854
Cekli S, Çırpan HA (2009) Localization of acoustic emitters with time delay compensated ML. Freq J RF-Eng Telecommun 63(3–4):69–76
Cekli S (2012) Position detection with spherical interpolation least squares based on time difference of arrivals using separated acoustic signals by independent component analysis. In: Signal processing and communications applications conference (SIU), pp 1–4
Young DP, Keller CM, Bliss DW, Forsythe KW (2003) Ultra-wideband (UWB) transmitter location using time difference of arrival (TDOA) techniques. In: Signals systems and computers conference record of the thirty-seventh Asilomar conference on 2, pp 1225–1229
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Gülnihar, K., Cekli, S., Uzunoğlu, C.P. et al. Location estimation of partial discharge-based electromagnetic source using multilateration with time difference of arrival method. Electr Eng 100, 839–847 (2018). https://doi.org/10.1007/s00202-017-0556-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00202-017-0556-9