High tilt susceptibility of the Scintrex CG-5 relative gravimeters

  • Short Note
  • Published:
Journal of Geodesy Aims and scope Submit manuscript

Abstract

We report on the susceptibility of the Scintrex CG-5 relative gravimeters to tilting, that is the tendency of the instrument of providing incorrect readings after being tilted (even by small angles) for a moderate period of time. Tilting of the instrument can occur when in transit between sites usually on the backseat of a car even using the specially designed transport case. Based on a series of experiments with different instruments, we demonstrate that the readings may be offset by tens of \(\upmu \)Gal. In addition, it may take hours before the first reliable readings can be taken, with the actual time depending on how long the instrument had been tilted. This sensitivity to tilt in combination with the long time required for the instrument to provide reliable readings has not yet been reported in the literature and is not addressed adequately in the Scintrex CG-5 user manual. In particular, the inadequate instrument state cannot easily be detected by checking the readings during the observation or by reviewing the final data before leaving a site, precautions suggested by Scintrex Ltd. In regional surveys with car transportation over periods of tens of minutes to hours, the gravity measurements can be degraded by some 10 \(\upmu \)Gal. To obtain high-quality results in line with the CG-5 specifications, the gravimeters must remain in upright position to within a few degrees during transits. This requirement may often be unrealistic during field observations, particularly when observing in hilly terrain or when walking with the instrument in a backpack.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

References

  • Christiansen L, Lund S, Andersen OB, Binning PJ, Rosbjerg D, Bauer-Gottwein P (2011) Measuring gravity change caused by water storage variations: performance assessment under controlled conditions. J Hydrol 402:60–70

    Article  Google Scholar 

  • Flury J, Peters T, Schmeer M, Timmen L, Wilmes H, Falk R (2007) Precision gravimetry in the new Zugspitze gravity meter calibration system. Harita Dergisi; Özel Sayi 18:401–406

    Google Scholar 

  • Jacob T, Bayer R, Chery J, Le Moigne N (2010) Time-lapse microgravity surveys reveal water storage heterogeneity of a karst aquifer. J Geophys Res 115:B06402. doi:10.1029/2009JB006616

    Google Scholar 

  • Lederer M (2009) Accuracy of the relative gravity measurement. Acta Geodyn Geomater 6:383–390

    Google Scholar 

  • Liard J, Gagnon CG, Hearty DB, Salib P, Flint TR (1993) Evaluation of the Scintrex CG-3 gravity meter. Geological Survey of Canada, open file 2696

  • Parseliunas E, Petroskevicius P, Obuchovski R (2008) Analysis of gravimetric observations made by Scintrex CG-5. Selected papers, 7th international conference on environmental engineering, May 22–23, Vilnius, Lithuania, 2008, pp 1422–1428

  • Parseliunas E, Petroskevicius P, Birvydiene R, Obuchovski R (2011) Investigation of the automatic gravimeters CG-5 and analysis of gravimetric measurements. Selected papers, 8th international conference on environmental engineering, May 19–20, Vilnius, Lithuania, 2011, pp 1416–1423

  • Parseliunas E, Petroskevicius P, Obuchovski R, Birvydiene R (2013) An investigation of the automatic relative gravimeters. Solid State Phenom 199:261–266

    Article  Google Scholar 

  • Scintrex Ltd. (2005) CG-3, 3M Autograv automated gravity meter operator manual, P.N: 858700 Version 5.00. Scintrex Limited, Concord

  • Scintrex Ltd. (2012a) CG-5 autograv gravity meter brochure, part number 867711, revision 2. Scintrex Limited, Concord

  • Scintrex Ltd. (2012b) CG-5 Scintrex autograv system operation manual, part I # 867700 revision 8. Scintrex Limited, Concord

  • Torge W (1989) Gravimetry. De Gruyter, Berlin, New York

  • Yushkin VD (2011) Operating experience with CG5 gravimeters. Meas Tech 54:486–489

    Article  Google Scholar 

  • Zumberge M, Alnes H, Eiken O, Sasagawa G, Stenvold T (2008) Precision of seafloor gravity and pressure measurements for reservoir monitoring. Geophysics 73(6):WA133–WA141. doi:10.1190/1.2976777

    Article  Google Scholar 

Download references

Acknowledgments

We want to thank two anonymous reviewers, the editor, Chris Jekeli, and Tonie van Dam, for providing valuable comments which helped us to improve the manuscript.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to R. Klees.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Reudink, R., Klees, R., Francis, O. et al. High tilt susceptibility of the Scintrex CG-5 relative gravimeters. J Geod 88, 617–622 (2014). https://doi.org/10.1007/s00190-014-0705-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00190-014-0705-0

Keywords

Navigation