Abstract
The face diagonal method for squareness error measurement is already well established. Because it is easy to apply, this method is widely used in CMMs (coordinate measuring machines). This paper introduces a new method, which reduces the set-up and measuring time for squareness error by applying four volumetric diagonal measurements instead of six face diagonal measurements. The method also makes it possible to use a single properly sized artefact, which fits the machine’s rectangular volume. The choice of artefacts used in the method is wide, and they need not be precalibrated before measurements.
Similar content being viewed by others
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Kruth, JP., Zhou, L., Van den Bergh, C. et al. A Method for Squareness Error Verification on a Coordinate Measuring Machine . Int. Journ. Adv. Manufac. Tech. 21, 874–878 (2003). https://doi.org/10.1007/s00170-002-1408-x
Issue Date: