Reliability and interobserver variability in radiological patellar height ratios

  • Knee
  • Published:
Knee Surgery, Sports Traumatology, Arthroscopy Aims and scope

Abstract

This study evaluated the reliability and interobserver variability of five patellar height ratios as measured by two examiners on standard radiographs: Insall-Salvati (IS), modified Insall-Salvati (MIS), Blackburne-Peel (BP), Caton-Deschamps (CD), and Labelle-Laurin (LL). Plain lateral radiographs with a knee flexion angle of 20° for IS, MIS, BP, and CD ratios and 90° for the LL method of 22 knees of 21 patients with varying pathological knee conditions were analyzed. Statistical results revealed a low interobserver variability with high correlation coefficients (0.86 for IS, 0.82 for MIS, 0.86 for BP, 0.92 for CD, and 0.81 for LL; P > 0.3) and low mean interobserver errors. However, regarding the reliability of the radiographic results of the different methods for patella alta, baja, or norma we found varying results in 68% of the patients. In two patients the patellar height was classified as alta, norma, or baja depending on the ratio used. Regarding the definitions of patellar height used by the authors of these methods, we found the lowest number of normal patellae with the IS ratio and no patella alta for the CD ratio. The LL method revealed the highest number of patella alta. The BP ratio showed intermediate results for both patella alta and baja, being the most moderate method. This study showed that there was a good interobserver reliability for the evaluation of patellar height according to the common radiological ratios. However, the high frequency of differing results between the different radiographic ratios showed that patellar height classification as “alta,”“norma,” or “baja” depends heavily on the chosen index. The differing results were due mainly to the normative patellar height data and to anatomical differences. Based on these findings we recommend a ratio using the articular surface of the patella in relation to the joint line. We recommend the BP method because it revealed the lowest interobserver variability and discriminated best among the groups alta, norma, and baja.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 6 December 1999 Accepted: 15 March 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Seil, R., Müller, B., Georg, T. et al. Reliability and interobserver variability in radiological patellar height ratios. Knee Surgery 8, 231–236 (2000). https://doi.org/10.1007/s001670000121

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s001670000121

Navigation