Skip to main content
Log in

The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty

  • Knee
  • Published:
Knee Surgery, Sports Traumatology, Arthroscopy Aims and scope

Abstract

Purpose

The aim of this study was to investigate the post-operative radiological outcomes of patient-specific instrumentation (PSI) surgery versus conventional total knee arthroplasty (TKA).

Methods

Sixty patients scheduled for a primary TKA were prospectively divided into PSI or conventional technique. Coronal and sagittal radiographic long limb films were taken post-operatively. The accepted values for normal alignment were 180° ± 3° for hip-knee-ankle angle; 90° ± 3° for coronal femoral component angle or coronal tibia component angle; 0° to 3° flexion for sagittal femoral component angle and 0° to 7° posterior slope for sagittal tibia component angle.

Results

For hip-knee-ankle angle, there were 21 % more outliers in the PSI group compared to the conventional group (p = 0.045). Most of these outliers had valgus deformity in the PSI group and varus deformity in the conventional group (p = 0.045). For implant placement, there was no difference in the proportion of outliers between the two groups. There was also no difference in the duration of surgery.

Conclusions

This study showed that PSI surgery is associated with a larger proportion of outliers for lower limb alignment. PSI surgery as an alternative to conventional TKA is not advisable.

Level of evidence

II.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Bauwens K, Matthes G, Wich M, Gebhard F, Hanson B, Ekkernkamp A, Stengel D (2007) Navigated total knee replacement: a meta-analysis. J Bone Joint Surg Am 89(2):261–269

    Article  PubMed  Google Scholar 

  2. Brin YS, Nikolaou VS, Joseph L, Zukor DJ, Antoniou J (2011) Imageless computer assisted versus conventional total knee replacement: a Bayesian meta-analysis of 23 comparative studies. Int Orthop 35(3):331–339

    Article  PubMed Central  PubMed  Google Scholar 

  3. Chandrasekaran S, Molnar RB (2008) Minimally invasive imageless computer-navigated knee surgery: initial results. J Arthroplasty 23(3):441–445

    Article  PubMed  Google Scholar 

  4. Chin PL, Foo LS, Yang KY, Yeo SJ, Lo NN (2007) Randomized controlled trial comparing the radiologic outcomes of conventional and minimally invasive techniques for total knee arthroplasty. J Arthroplasty 22(6):800–806

    Article  PubMed  Google Scholar 

  5. Chin PL, Yang KY, Yeo SJ, Lo NN (2005) Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplasty 20(5):618–626

    Article  PubMed  Google Scholar 

  6. Conteduca F, Iorio R, Mazza D, Caperna L, Bolle G, Argento G, Ferretti A (2012) Evaluation of the accuracy of a patient-specific instrumentation by navigation. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-012-2098-z

    Google Scholar 

  7. Coughlin KM, Incavo SJ, Churchill DL, Beynnon BD (2003) Tibial axis and patellar position relative to the femoral epicondylar axis during squatting. J Arthroplasty 18(8):1048–1055

    Article  PubMed  Google Scholar 

  8. Desai AS, Dramis A, Kendoff D, Board TN (2011) Critical review of the current practice for computer-assisted navigation in total knee replacement surgery: cost-effectiveness and clinical outcome. Curr Rev Musculoskelet Med 4(1):11–15

    Article  PubMed Central  PubMed  Google Scholar 

  9. Duparc J, Massare C (1967) Radiological measurement of the angular deviation of the knee in the frontal plane. Ann Radiol (Paris) 10(9):635–656

    CAS  Google Scholar 

  10. Eckhoff D, Hogan C, DiMatteo L, Robinson M, Bach J (2007) Difference between the epicondylar and cylindrical axis of the knee. Clin Orthop Relat Res 461:238–244

    PubMed  Google Scholar 

  11. Eckhoff DG, Bach JM, Spitzer VM, Reinig KD, Bagur MM, Baldini TH, Flannery NM (2005) Three-dimensional mechanics, kinematics, and morphology of the knee viewed in virtual reality. J Bone Joint Surg Am 87(Suppl 2):71–80

    Article  PubMed  Google Scholar 

  12. Fang DM, Ritter MA, Davis KE (2009) Coronal alignment in total knee arthroplasty: just how important is it? J Arthroplasty 24(Suppl 6):39–43

    Article  PubMed  Google Scholar 

  13. Hollister AM, Jatana S, Singh AK, Sullivan WW, Lupichuk AG (1993) The axes of rotation of the knee. Clin Orthop Relat Res 290:259–268

    PubMed  Google Scholar 

  14. Jeffery RS, Morris RW, Denham RA (1991) Coronal alignment after total knee replacement. J Bone Joint Surg Br 73(5):709–714

    CAS  PubMed  Google Scholar 

  15. Kharwadkar N, Kent RE, Sharara KH, Naique S (2006) 5° to 6° of distal femoral cut for uncomplicated primary total knee arthroplasty: is it safe? Knee 13(1):57–60

    Article  CAS  PubMed  Google Scholar 

  16. Longstaff LM, Sloan K, Stamp N, Scaddan M, Beaver R (2009) Good alignment after total knee arthroplasty leads to faster rehabilitation and better function. J Arthroplasty 24(4):570–578

    Article  PubMed  Google Scholar 

  17. Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Joint Surg Am 59(1):77–79

    CAS  PubMed  Google Scholar 

  18. Lustig S, Scholes CJ, Oussedik SI, Kinzel V, Coolican MR, Parker DA (2013) Unsatisfactory accuracy as determined by computer navigation of VISIONAIRE patient-specific instrumentation for total knee arthroplasty. J Arthroplasty 28(3):469–473

    Article  PubMed  Google Scholar 

  19. Marx RG, Grimm P, Lillemoe KA, Robertson CM, Ayeni OR, Lyman S, Bogner EA, Pavlov H (2011) Reliability of lower extremity alignment measurement using radiographs and PACS. Knee Surg Sports Traumatol Arthrosc 19(10):1693–1698

    Article  CAS  PubMed  Google Scholar 

  20. Nunley RM, Ellison BS, Ruh EL, Williams BM, Foreman K, Ford AD, Barrack RL (2012) Are patient-specific cutting blocks cost-effective for total knee arthroplasty? Clin Orthop Relat Res 470:889–894

    Article  PubMed  Google Scholar 

  21. Nunley RM, Ellison BS, Zhu J, Ruh EL, Howell SM, Barrack RL (2012) Do patient-specific guides improve coronal alignment in total knee arthroplasty? Clin Orthop Relat Res 470:895–902

    Article  PubMed  Google Scholar 

  22. Ritter MA, Faris PM, Keating EM, Meding JB (1994) Postoperative alignment of total knee replacement: its effect on survival. Clin Orthop Relat Res 299:153–156

    PubMed  Google Scholar 

  23. Sparmann M, Wolke B, Czupalla H, Banzer D, Zink A (2003) Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. J Bone Joint Surg Br 85(6):830–835

    CAS  PubMed  Google Scholar 

  24. Stronach BM, Pelt CE, Erickson J, Peters CL (2013) Patient-specific total knee arthroplasty required frequent surgeon-directed changes. Clin Orthop Relat Res 471:169–174

    Article  PubMed  Google Scholar 

  25. Wasielewski RC, Galante JO, Leighty RM, Natarajan RN, Rosenberg AG (1994) Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty. Clin Orthop Relat Res 299:31–43

    PubMed  Google Scholar 

Download references

Conflict of interest

The authors did not receive any outside funding or grants in support of their research for or preparation of this work. Neither they nor a member of their immediate families received payments or other benefits or a commitment or agreement to provide such benefits from a commercial entity.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Jerry Yongqiang Chen.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Chen, J.Y., Yeo, S.J., Yew, A.K.S. et al. The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22, 630–635 (2014). https://doi.org/10.1007/s00167-013-2638-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00167-013-2638-1

Keywords

Navigation