Introduction

The medial side of the knee contains static and dynamic stabilizers that contribute to resisting valgus and rotational forces. The medial collateral ligament (MCL) is the primary stabilizer against valgus stress, especially at lower flexion angles. At 25º of flexion, the MCL provides 78% of the restraining force against valgus injury [1]. At full extension, the MCL provides 57% of the restraining force, with the posterior oblique ligament (POL), ACL, and posteromedial capsule responsible for the majority of the remaining restraint. The MCL comprises two distinct structures: the superficial and deep MCL. The superficial MCL (sMCL) originates on an average of 3.2 mm proximal and 4.8 mm posterior to the medial epicondyle [2]. It inserts at two distinct points on the proximal medial tibia, just anterior to the posteromedial crest of the tibia. The deep portion of the MCL originates inferior to the medial epicondyle and inserts 1 cm below the joint line on the tibia.

Injuries to the medial structures of the knee are very common, particularly in contact and pivoting sports such as American football and soccer [35]. Despite the frequency of these injuries, successful treatment can be achieved with non-operative management in a majority of MCL injuries. Similar results have been found with both operative and non-operative management of these injuries [6]. Athletes with combined ACL–MCL injuries can expect acceptable stability and a good to excellent functional outcome with isolated ACL reconstruction alone [7, 8]. However, knee dislocations with injury to both the medial and lateral side of the knee may require superficial MCL reconstruction in up to 85% of patients [9]. There are also a small but significant number of patients who continue to have residual symptoms of pain, instability, or both following an MCL injury and require surgical reconstruction [10].

There have been numerous techniques described for superficial MCL reconstruction, many of which do not attempt to reconstruct the native anatomy of the medial side of the knee. The original reconstruction technique described by Bosworth was a non-anatomic reconstruction using the semi-tendonosus tendon [11]. The maintenance of graft isometry or constant length during knee range of motion has been advocated as an important goal in knee ligament reconstruction [12, 13].

The purpose of this study was to determine the femoral and tibial fixation sites that would result in the most isometric superficial MCL reconstruction technique. We also wished to determine at which flexion angles the grafts should be fixed in order to best restore knee stability. We hypothesized that an anatomic reconstruction that better replicated the native knee anatomy would result in the most isometric reconstruction. We used computer assisted navigation to determine graft length and isometry because it has previously been found to be a precise biomechanics tool to measure graft isometry [12, 14].

Methods

Seven fresh-frozen cadaveric knees that had been used in a previous study were used in the current study. The knees had an average age of 51.3 years. Five were male knees, two were female. Knees were excluded from the study if there was ligamentous laxity, significant arthritic changes, gross malalignment, or evidence of previous surgery. The tibia and femur were sectioned at the mid-shaft and soft tissue was removed up to 15 cm from the joint line. The specimens were mounted and secured using a vice attached to the proximal femur. The knees were mounted to allow free range of motion from 0º to 110º of flexion.

The medial side of the knee was dissected and exposed to visualize the MCL. The femoral attachment of the superficial MCL was identified and carefully dissected free from its proximal insertion. The attachment of the superficial MCL on the proximal medial tibia was similarly dissected and marked to identify the proximal and distal insertions of the sMCL. The deep MCL was then identified and its proximal and distal attachments were identified. The semitendinosus tendon was then identified in the pes anserinus and its insertion was dissected and marked accordingly. An isometric map was then generated with multiple points on the medial distal femur and the proximal tibia (Fig. 1). The distal femoral points corresponded to the femoral attachment of the MCL (FC), and 4 mm superior (FS), inferior (FI), anterior (FA), and posterior (FP) to the origin. There were four points registered on the tibia: one that corresponded to the anterior proximal (TP) aspect of the proximal attachment of the sMCL, one for the distal attachment of the sMCL (TD), one at the midpoint between the proximal and distal attachment (TM), and one for the insertion of the semitendonosus (TH).

Fig. 1
figure 1

Schematic of each point taken for isometry measurments. There were five points taken on the femur, based on the femoral attachment of the superficial MCL (Center MCL). A separate measurement point was created 4 mm in each direction (anterior, posterior, superior, and inferior) from the center of the MCL femoral attachment. On the tibial side, four points were again identified. One point was at the superior tibial attachment of the superficial MCL. One point was at the distal insertion of the sMCL. One point was at the midpoint of the sMCL attachment. Finally, one was at the semitendonosus insertion. ME Medial epicondyle; F S Superior femoral attachment of the MCL; F C Center of sMCL attachment on femur; F I Interior femoral attachment; F P Posterior femoral attachment; F A Anterior femoral attachment; T M Midpoint of the attachment of the sMCL on the tibia; T H Semitendinosus insertion on tibia; T P Proximal aspect of sMCL attachment on tibia; T A Anterior aspect of sMCL attachment on tibia; T D Distal aspect of sMCL attachment on tibia. Figure courtesy of Joseph Smith, ATC

The Praxim Surgetics surgical navigation system (PraximMedivision, Grenoble, France) was used to acquire isometric data. The Surgetics ACL Logics Universal Software was used for data acquisition as previously described [14]. The technology generated a three dimensional image of the articular anatomy by acquiring reference points directly on the bony surfaces and then forming a statistical model to fit these points. The reference points included the center of the femoral notch, the middle of the transverse meniscal ligament on the anterior tibia, and the center of the medial and lateral tibial plateaus. This system has been shown to be precise; within 1° or 1 mm compared with an industrial robotic sensor [1416]. Threaded Steinmann pins were placed in the proximal femur and distal tibia to mount the reflective markers. Surface landmarks on the tibial plateau and distal femur were recorded, intraarticular surface geometry was mapped, and the 3-D model was created. The knee was manually cycled from full extension to 110° of flexion.

The isometry of each graft reconstruction, defined as the change in graft length through a given range of motion, was determined at continuous intervals from 0º to 90º of knee flexion as recorded by the navigation software. Fiber lengths were normalized to zero at full extension. The length change between the fiber length at full extension and the fiber length at the respective flexion angle was computed at 5º increments from 0º to 90º. These length changes were subsequently plotted to demonstrate the anisometry ‘profile’ of each fixation point from 0º to 90º. The total length change in each fiber was also computed, as was the strain in the fiber (ΔL/L).

Repeated measures ANOVA was used to compare the anisometry of the grafts at the various flexion angles. Significance was defined as a P value less than 0.05. Data are expressed as the mean ± standard error of the mean (SEM).

Results

The isometric data are summarized in Table 1. Proximally, placement of the graft at the center of the superficial MCL attachment on the femur resulted in the best overall graft isometry. The mean change in length from the center of the MCL to the proximal (TP) and distal tibial insertions (TD) of the MCL on the tibia were 2.7 ± 1.2 mm and 2.8 ± 1.1 mm, respectively. There was no significant difference in length change with placement of the graft on the anterior aspect of the tibial attachment (TA) or at the midpoint of the attachment (TM). However, the mean change in length was significantly greater with placement of the graft anteriorly at the site of the semitendonosus insertion (TH) (4.1±, P < 0.05) which would correspond to the placement of the anterior limb of the modified Bosworth technique.

Table 1 Isometry of graft positions

Movement of the graft anteriorly 4 mm (FA) from the origin of the sMCL resulted in a greater mean change of length with the graft fixed distally at the anterior aspect of the insertion as well as at the hamstring insertion (Table 1). Posterior fixation (FP) of the graft led to significant increases in mean length change at all points within the MCL insertion. Similarly, fixation of the graft at either FS or FI led to greater anisometry with each point tested on the tibia. The greatest anisometry was seen from FS to TH (10.8 ± 3.1 mm, P < 0.01 vs. FC to all tibial points).

The strain measurements are reported in Table 2. The overall mean strain measurements were low, with none reaching greater than 0.11. The grafts positioned in the points that corresponded to the most anatomic reconstruction (FC to TP and TD) had the lowest strain (ε = 0.02 ± 0.005). The strain was greatest in the least isometric positions, especially from the FS to TH (ε = 0.12 ± 0.04).

Table 2 Strain (ε) of each graft position

The absolute graft lengths were longest with the knee in full extension, regardless of the fixation points selected. As the knee was flexed to 90º, the absolute graft lengths shortened with all fixation configurations. A majority of the shortening occurred from 0 to 30º, suggesting that the graft should be tensioned at lower flexion angles to avoid over constraint of the knee as the knee is flexed. Representative graft isometry graphs demonstrating the most isometric and least isometric configurations are shown in Fig. 2.

Fig. 2
figure 2

Mean relative length changes of select MCL reconstruction techniques. The values are references to the value of the absolute graft length at 0º of flexion. Positive numbers reflect graft shortening as the knee is flexed toward 90º. Negative numbers reflect graft lengthening. F S Superior femoral origin; F C Center of MCL origin on femur. T H Hamstring insertion on tibia; T P Proximal aspect of MCL insertion on tibia; T A Anterior aspect of MCL insertion on tibia; T D Distal aspect of MCL insertion on tibia

Discussion

In this study, we found that the ideal isometric reconstruction of the superficial MCL was with the graft originating at the anatomic femoral attachment of the sMCL and was placed on the proximal and distal attachments of the sMCL on the tibia. This position also led to the least strain on the graft.

The optimal isometric position of the MCL reconstruction on the femur was with the graft placed at the femoral attachment of the sMCL. Placement of the graft 4 mm in any direction away from the sMCL origin resulted in significant increases in graft length during knee range of motion, suggesting that precise anatomic placement of the graft within this region is important in maintaining knee stability following reconstruction. In this study, great care was taken to identify the anatomic location of the origin of the sMCL as it related to the medial epicondyle. Our data were similar to data reported by LaPrade et al. [2]. We found that the sMCL attaches to the femur just proximal and posterior to the medial epicondyle. Although there is some variability between samples, all sMCL attachments were within 5 mm proximal and posterior to the medial epicondyle, suggesting this is a reliable landmark to reproduce the femoral attachment of the sMCL during reconstruction.

Distally, the most isometric points of graft fixation were with the graft fixed in the proximal or distal aspects of the sMCL insertion on the medial aspect of the tibia. Fixation of the graft anteriorly in the semitendonosus insertion led to significantly greater changes in graft length. These data have several important clinical implications. First, many surgeons prefer to use a modification of the Bosworth technique where the semitendonosus tendon is left intact at the insertion, attached proximally on the medial side of the femur, and attached distally in the MCL footprint. This study suggests that fixation with this technique leads to a very anisometric reconstruction and may result in clinical laxity over time. However, the calculated strain with the graft placed anteriorly in the semitendonosus footprint was only minimally greater than when placed in the MCL footprint. A second important clinical finding was that there were two optimal isometric points within the insertion of the sMCL. Recent studies in our lab have found that an anatomic double bundle MCL reconstruction best restored native knee laxity patterns [17]. Fixation of a double bundle graft both proximally and distally within the footprint of the MCL would lead to a reconstruction with good overall isometry.

A majority of the studies on graft isometry has been performed on cruciate ligament reconstructions, and only recently have studies evaluated graft isometry on the posterolateral corner [18]. Graft isometry is important for any ligament reconstruction in order to effectively stabilize the joint during the entire range of motion. This study demonstrates that the relative lengths of MCL grafts decrease with knee flexion, and most of this length decrease occurs from 45º to 90º. If a graft was tensioned with the knee flexed to 90º, it would result in a graft that would be excessively tightened as the knee was extended to 0º. The excessive tension in the graft could lead to excessive graft forces which can cause the graft to permanently stretch or even fail during the early healing period. Conversely, if the graft was fixed at or close to full extension, the graft would slacken slightly and not over constrain the knee as it was flexed toward 90º. Thus, any MCL reconstruction should be tensioned at or close to full extension.

There are several weaknesses to this study. The use of computer assisted navigation to evaluate isometry has only recently been utilized, and the technology has not been validated with independent studies. Previous studies on our lab have used this technique to accurately determine ACL isometry that was consistent with earlier published data [12]. In addition most previous isometric studies have used single sutures to measure graft length changes, which may not account for differential isometry within a 7–9 mm graft. The computer assisted navigation system that we utilize averages the isometry for a proposed graft, which may be more precise than using a suture technique to measure graft length change. Studies comparing the two techniques would be beneficial. A second weakness of this study is that although it found significant differences in graft isometry, it cannot answer whether these changes would be clinically relevant, especially in light of the fact that there were only small changes in the strain seen with each graft configuration. Clinical studies evaluating the outcomes with grafts in different configurations would help determine if small changes in graft position truly result in different clinical outcomes.

Conclusion

Our results suggest that sMCL reconstruction performed with the femoral attachment of the MCL within the femoral footprint and the tibial attachment within the footprint of the sMCL will result in the least graft excursion when the knee is cycled between 0º and 90º. Graft fixation should be performed at or near full extension in order to not over constrain the knee or overload the MCL reconstruction, which could lead to early failure of the reconstruction.