Abstract
Poly-l-lactic acid biodegradable screws have been used effectively for graft fixation in anterior cruciate ligament (ACL) reconstruction. The overall complication rate associated with the use of this implant is low, although some authors reported complications, such as osteolysis and aseptic effusion of the knee joint. We report a case of a 29-year-old female patient with a failure of a biodegradable interference screw at 22 months after ACL reconstruction using bone–patellar tendon–bone graft. In this illustrated case, the screw broke and migrated into the knee joint. In addition, we performed a detailed review of the medical literature from 1990–2005 to identify possible causes of biodegradable screw failures. We identified six published cases of bioabsorbable interference screw failure with migration into the knee joint. Several authors have reported small diameter of the screw, poor bone quality, bone resorption, and screw divergence as potential causes for intraarticular migration of metallic interference screws. With regard to bioscrews, no specific risk factors for screw breakage and intraarticular migration have been reported. ACL reconstruction with the use of bioabsorbable interference screws for fixation is considered to be reliable. However, we need to be aware of potential problems associated with the use of this implant. Early recognition of bioscrew failure may prevent associated morbidities, such as subsequent cartilage damage.
Similar content being viewed by others
References
Barber FA (1999) Tripled semitendinosus-cancellous bone anterior cruciate ligament reconstruction with bioscrew fixation. Arthroscopy 15:360–367
Barber FA, Elrod BF, McGuire DA, Paulos LE (2000) Fixation of patellar tendon autografts. Biomaterials 21:2623–2629
Barrett GR, Papendick L, Miller C (1995) Endobutton endoscopic fixation technique in anterior cruciate ligament reconstruction. Arthroscopy 11:340–343
Benedetto KP, Fellinger M, Lim TE, Passler JM, Schoen JL, Willems WJ (2000) A new bioabsorbable interference screw: preliminary results of a prospective, multicenter, randomized clinical trial. Arthroscopy 16:41–48
Bottoni C, DeBerardino T, Fester E, Mitchell D, Penrod BJ (2000) An intra-articular bioabsorbable interference screw mimicking an acute meniscal tear 8 months after an anterior cruciate ligament reconstruction. Arthroscopy 16:395–398
Bush-Joseph CA, Bach BR Jr (1998) Migration of femoral interference screw after anterior cruciate ligament reconstruction. Am J Knee Surg 11:32–34
Cerullo G, Puddu G (1993) Arthroscopic placement of the interference screw for anterior cruciate ligament reconstruction. Arthroscopy 9:712–713
Doerr AL Jr, Cohn BT, Ruoff MJ, McInerny VK (1990) A complication of interference screw fixation in anterior cruciate ligament reconstruction. Orthop Rev 19:997–1000
Karlakki SL, Downes ME (2003) Intra-articular migration of femoral interference screw: open or arthroscopic removal. Arthroscopy 19:19E
Kohn D, Rose C (1994) Primary stability of interference screw fixation. Influence of screw diameter and insertion torque. Am J Sports Med 22:334–338
Lembeck B, Wülker N (2005) Severe cartilage damage by broken poly-l-lactic acid (PLLA) interference screw after ACL reconstruction. Knee Surg Sports Traumatol Arthrosc 13:283–286
Lu HH, Cooper JA Jr, Manuel S, Freeman JW, Attawia MA, Ko FK, Laurencin CT (2005) Anterior cruciate ligament regeneration using braided biodegradable scaffolds: in vitro optimization studies. Biomaterials 26:4805–4816
MacDonald P, Arneja S (2003) Biodegradable screw presents as a loose intra-articular body after anterior cruciate ligament reconstruction. Arthroscopy 19: E22–E24
Marti C, Imhoff AB, Bahrs C, Romero J (1997) Metallic versus bioabsorbable interference screw for fixation of bone–patellar tendon–bone autograft in arthroscopic anterior cruciate ligament reconstruction. A preliminary report. Knee Surg Sports Traumatol Arthrosc 5:217–221
Martinek V, Friederich NF (1999) Tibial and pretibial cyst formation after anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation. Arthroscopy 15:317–320
Morgan CD, Gehrmann RM, Jayo MJ, Johnson CS (2002) Histologic findings with a bioabsorbable anterior cruciate ligament interference screw explant after 2.5 years in vivo. Arthroscopy 18:E47
Rodeo SA, Arnoczky SP, Torzilli PA, Hidaka C, Warren RF (1993) Tendon-healing in a bone tunnel. A biomechanical and histological study in dog. J Bone Joint Surg Am 75-A:1795–1803
Shafer BL, Simonian PT (2002) Broken poly-l-lactic acid interference screw after ligament reconstruction. Arthroscopy 18:E35
Sidhu DS, Wroble RR (1997) Intraarticular migration of a femoral interference fit screw. A complication of anterior cruciate ligament reconstruction. Am J Sports Med 25:268–271
Stähelin AC, Weiler A, Rüfenacht H, Hoffmann R, Geissmann A, Feinstein R. (1997) Clinical degradation and biocompatibility of different bioabsorbable interference screws: a report of six cases. Arthroscopy 13:238–244
Stähelin AC, Südkamp NP, Weiler A (2001) Anatomic double-bundle posterior cruciate ligament reconstruction using hamstring tendons. Arthroscopy 17:88–97
Werner A, Wild A, Ilg A, Krauspe R (2002) Secondary intra-articular dislocation of a broken bioabsorbable interference screw after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc 10:30–32
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Baums, M.H., Zelle, B.A., Schultz, W. et al. Intraarticular migration of a broken biodegradable interference screw after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthr 14, 865–868 (2006). https://doi.org/10.1007/s00167-006-0049-2
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00167-006-0049-2