C1-esterase inhibitor in graft failure after lung transplantation

  • BRIEF REPORT
  • Published:
Intensive Care Medicine Aims and scope Submit manuscript

Abstract

Graft failure after lung transplantation may occur immediately after transplantation due to reperfusion injury or later due to rejection and infection. Although the pathological mechanisms are not completely known, the clinical findings are similar to the adult respiratory distress syndrome. In this condition, the blood coagulation contact system and the complement system are activated, leading to a capillary leak syndrome. Activation of the contact as well as the complement system is regulated by a common inhibitor, C1-esterase inhibitor (C1-INH). We report on two patients who received high doses of C1-INH for 2 days during graft failure either due to reperfusion injury immediately after transplantation or due to an acute rejection 2 months after double-lung transplantation. In both cases of graft failure, a capillary leak syndrome occurred with pleural effusions of 7 l to more than 10 l per day. In case 1 disturbance of gas exchange during severe reperfusion injury could not be treated effectively with other treatment modalities like nitric oxide ventilation or surfactant administration. With the use of C1-INH, pleural effusions reduced within 12 h, leading to normal graft function within 4 days. In the second recipient, acute rejection forced the use of extracorporeal membrane oxygenation (ECMO) within 24 h despite immunosuppressive therapy. After administration of C1-INH, pleural effusions reduced from 19 l per day to 300 ml within 3 days of treatment. ECMO was discontinued after C1-INH treatment and the patient extubated 2 weeks later. This experience indicates that C1-INH may play a role in the management of capillary leak syndrome after lung transplantation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 28 May 1999/Final revision received: 3 September 1999/Accepted: 13 September 1999

Rights and permissions

Reprints and permissions

About this article

Cite this article

Strüber, M., Hagl, C., Hirt, S. et al. C1-esterase inhibitor in graft failure after lung transplantation. Intensive Care Med 25, 1315–1318 (1999). https://doi.org/10.1007/s001340051065

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s001340051065

Keywords

Navigation