Comparison of commonly used clinical indicators of hypovolaemia with gastrointestinal tonometry

  • ORIGINAL
  • Published:
Intensive Care Medicine Aims and scope Submit manuscript

Abstract

Objective: The gastrointestinal tonometer, which allows measurement of gastrointestinal mucosal CO2 and subsequent derivation of gut intramucosal pH (pHi), has been demonstrated to be a sensitive predictor of outcome following major surgery. Current theory suggests that the origin of the low pH may be hypovolaemia. This study was designed to compare the temporal sequence of changes in tonometric readings with invasive blood pressure, stroke volume, heart rate, lactate and arterial blood gas measurements during progressive haemorrhage. Design: Observational healthy volunteer study. Setting: Intensive care unit at University College London Hospitals. Subjects: Six healthy, medically qualified volunteers. Interventions: After obtaining baseline measurements, the subjects were progressively bled 25 % (range = 21–31 %) of their blood volume over a period of 1 h in two approximately equal aliquots. Equilibration was allowed for 30 min following the bleed, after which further measurements were made and the blood was then retransfused over 30 min. Measurements and main results: There was no consistent change in any of the haemodynamic variables other than gastric intramucosal CO2 : arterial CO2 gap (PiCO2− PaCO2) after removal of the first aliquot of blood, although five of the six subjects also demonstrated a fall in pHi. After removal of the second aliquot of blood, PiCO2− PaCO2 gap and pHi continued to indicate a worsening gastric intramucosal acidosis; stroke volume, as measured by suprasternal Doppler, demonstrated a marked fall, while all other variables measured had not altered consistently or to such a degree as to elicit a clinical response or cause suspicion of a hypovolaemic state. On retransfusion, all variables returned towards baseline. Conclusions: This study demonstrates the value of tonometry as an early monitor of hypovolaemia and highlights the shortcomings of other more commonly measured clinical variables.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 18 January 1996 Accepted: 4 December 1996

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hamilton-Davies, C., Mythen, M., Salmon, J. et al. Comparison of commonly used clinical indicators of hypovolaemia with gastrointestinal tonometry. Intensive Care Med 23, 276–281 (1997). https://doi.org/10.1007/s001340050328

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s001340050328

Navigation