Avoid common mistakes on your manuscript.
Severe hypoxemia, alveolar infiltrates associated to increased permeability, and histological damage due to lung inflammation constitute the key elements of the conceptual model of acute respiratory distress syndrome (ARDS). While tidal volumes (VT) of 12–14 ml/kg and end-inspiratory plateau pressures (PPLAT) up to 50 cmH2O were initially used to “normalize” arterial blood gases [1], experimental and clinical studies performed in the last 20 years consistently demonstrated that such ventilatory approaches worsened lung damage (ventilator-induced lung injury, VILI) [2]. The seminal trial performed by the ARDS Network showed that, compared to a traditional “high VT” (12 ml/kg predicted body weight, PBW), the use of a “low VT” (6 ml/kg PBW) significantly reduced mortality from 40% to 31% [3]. Consequently, 6 ml/kg normalized to PBW has been established as the standard VT for patients with ARDS (Fig. 1). Although the range of 6–8 ml/kg PBW is acknowledged as the standard [4], various factors question the use of 6 ml/kg PBW as a fixed cut-off.
First, at the moment there are no clinical studies that have evaluated whether the influence on outcomes of VT of 6 ml/kg is equivalent, better, or worse compared to the effects associated with VT ranging from 7 to 11 ml/kg [5, 6]. Second, a recent meta-analysis informing the current guidelines showed that, although being recommended by experts, “lower VT” (i.e., 4–8 ml/kg PBW) does not have a significant effect size on patient outcome [5]. It should be emphasized that this meta-analysis was performed including only three trials (the ARDS Network study and two smaller trials), and its heterogeneity was moderate-high (I2 61%). Third, a significant number of patients ventilated with “low VT” still exhibit signs of hyperinflation [7]. Fourth, setting VT based on “milliliters per kilogram of PBW” in order to normalize it to lung size might be misleading [8, 9], since this approach overlooks the fact that the proportion of lung available for ventilation is significantly decreased in ARDS. In alternative, VT may be scaled to the aerated portion of the lung as estimated by the compliance of the respiratory system (CRS). Amato and coworkers proposed driving pressure (ΔP = VT/CRS) as the most accurate “ventilator predictor” of outcome in patients with ARDS and demonstrated that the favorable effects of randomly assigned reductions in VT were largely mediated by the decrease in ΔP [8].
A simplified reading of these arguments may lead to the suggestion that VT should be set to optimize ΔP and CRS (i.e., the elastic components of mechanical power contributing to VILI) [11]. Nevertheless, in our view, all the above discussed arguments raise two still unresolved questions: (a) Is ΔP an indicator of unsafe VT and does it have a direct impact on the outcome? (b) What factors can influence CRS and the interplay between VT and ΔP? Addressing these issues is crucial for clinicians to tailor VT, enhance mechanical ventilation, and minimize the potential risk for VILI.
-
(a)
Is ΔP an indicator of unsafe VT and does it have a direct impact on the outcome?
ΔP was originally proposed as the ventilation variable that best stratifies the risk of hospital death [8]. More recently, an emulated randomized trial based on registry of invasively and non-invasively ventilated patients showed that the 30-day ventilatory mortality was 20.1%. A 1.9% and 4.4% reduction of the absolute risk of 30-day ventilator mortality was shown for ΔP < 15 and < 10 cmH2O, respectively [10]. This may be especially true when ΔP is limited at the very onset of mechanical ventilation and for a longer ventilation time [11]. Interestingly, ΔP was shown to be correlated to mortality if calculated statically (i.e. using in the calculation end-inspiratory plateau pressure) or dynamically (i.e. using in the calculation peak-inspiratory pressure) [10, 11]. Although a recent trial failed to support the use of VT < 6 ml/kg PBW when implemented with extracorporeal CO2 removal [12], the absence of lower safe limits still encourage further studies to evaluate the clinical efficacy of “ultra-protective” ventilation [13].
-
(b)
What factors can influence CRS and the interplay between VT and ΔP?
The level of positive end-expiratory pressure (PEEP) selected by the clinician as well as the elastic components of the chest wall (chest wall elastance: ECW) have an important influence on CRS, and on the interplay between VT and ∆P. Under these circumstances, the component of mechanical stress imputable to (a) lung volume (as influenced by the level of applied PEEP) and (b) to the partitioning of respiratory mechanics between chest wall and lung components (as assessed by measurement of ECW) may both affect CRS and ∆P for a given VT [2]. Clinical trials comparing high vs low PEEP did not target a limited ∆P strategy, whereas studies testing physiology-guided protocols to set PEEP used different methodologies (e.g., aiming at end-expiratory transpulmonary pressure of zero, or at the highest CRS following or not lung recruitment) [5]. Moreover, several other uncontrolled factors may contribute to the variable effects of ∆P and PEEP optimization. They include severity and pattern of injury, body positioning, airway closure and hemodynamic and the non-homogeneous distribution of ventilation makes regional stress not necessarily mirrored by a single values of ∆P and/or CRS [7]. In this context, stress index (describing the changes in compliance with tidal inflation), lung imaging technique (e.g., electric impedance tomography and computed tomography) and estimation of pleural pressure, may guide personalized ∆P and PEEP setting aiming at a more homogeneous distribution of ventilation and regional lung mechanics [14].
Take-home message
The ARDS Network study was the seminal study introducing the concept of protective mechanical ventilation. However, a fixed VT cut-off (6 ml/kg PBW) has been recently questioned [9,10,11]. New evidence suggests that it may be more advantageous to optimize VT considering ∆P. Regional distribution of volumes and regional lung mechanics may be the missing factor, although not demonstrated on a large scale. While waiting for more research on the topic, clinicians must continue using the concept of protective ventilation considering the multifactorial contribution of ∆P, CRS, ECW, PEEP, and regional lung mechanics, to individualize VT.
References
Pontoppidan H, Hedley-Whyte J, Bendixen HH et al (1965) Ventilation and oxygen requirements during prolonged artificial ventilation in patients with respiratory failure. N Engl J Med 273:401–409. https://doi.org/10.1056/NEJM196508192730801
Slutsky AS, Ranieri VM (2013) Ventilator-induced lung injury. N Engl J Med 369:2126–2136. https://doi.org/10.1056/NEJMra1208707
Network ARDS, Brower RG, Matthay MA et al (2000) Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med 342:1301–1308. https://doi.org/10.1056/NEJM200005043421801
Bellani G, Laffey JG, Pham T et al (2016) Epidemiology, patterns of care, and mortality for patients with acute respiratory distress syndrome in intensive care units in 50 countries. JAMA 315:788–800. https://doi.org/10.1001/jama.2016.0291
Grasselli G, Calfee CS, Camporota L et al (2023) ESICM guidelines on acute respiratory distress syndrome: definition, phenotyping and respiratory support strategies. Intensive Care Med 49:727–759. https://doi.org/10.1007/s00134-023-07050-7
Tobin MJ (2021) The dethroning of 6 ml/kg as the “Go-To” setting in acute respiratory distress syndrome. Am J Respir Crit Care Med 204:868–869. https://doi.org/10.1164/rccm.202105-1320LE
Terragni PP, Rosboch G, Tealdi A et al (2007) Tidal hyperinflation during low tidal volume ventilation in acute respiratory distress syndrome. Am J Respir Crit Care Med 175:160–166. https://doi.org/10.1164/rccm.200607-915OC
Amato MBP, Meade MO, Slutsky AS et al (2015) Driving pressure and survival in the acute respiratory distress syndrome. N Engl J Med 372:747–755. https://doi.org/10.1056/NEJMsa1410639
Goligher EC, Costa ELV, Yarnell CJ et al (2021) Effect of lowering VT on mortality in acute respiratory distress syndrome varies with respiratory system Elastance. Am J Respir Crit Care Med 203:1378–1385. https://doi.org/10.1164/rccm.202009-3536OC
Urner M, Jüni P, Rojas-Saunero LP et al (2023) Limiting dynamic driving pressure in patients requiring mechanical ventilation*. Crit Care Med 51:861. https://doi.org/10.1097/CCM.0000000000005844
Urner M, Jüni P, Hansen B et al (2020) Time-varying intensity of mechanical ventilation and mortality in patients with acute respiratory failure: a registry-based, prospective cohort study. Lancet Respir Med 8:905–913. https://doi.org/10.1016/S2213-2600(20)30325-8
McNamee JJ, Gillies MA, Barrett NA et al (2021) Effect of lower tidal volume ventilation facilitated by extracorporeal carbon dioxide removal vs standard care ventilation on 90-day mortality in patients with acute hypoxemic respiratory failure: the REST randomized clinical trial. JAMA 326:1013–1023. https://doi.org/10.1001/jama.2021.13374
Combes A, Fanelli V, Pham T et al (2019) Feasibility and safety of extracorporeal CO2 removal to enhance protective ventilation in acute respiratory distress syndrome: the SUPERNOVA study. Intensive Care Med 45:592–600. https://doi.org/10.1007/s00134-019-05567-4
Jonkman AH, Ranieri VM, Brochard L (2022) Lung recruitment. Intensive Care Med 48:936–938. https://doi.org/10.1007/s00134-022-06715-z
Acknowledgements
We thank Gaetano Perchiazzi for the discussion and revision of this work.
Funding
Research time for MP is granted from Svenska Sällskapet för Medicinsk Forskning (Grant SG-22-0086-H-03).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflicts of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc/4.0/.
About this article
Cite this article
Pellegrini, M., Del Sorbo, L. & Ranieri, V.M. Finding the optimal tidal volume in acute respiratory distress syndrome. Intensive Care Med 50, 1154–1156 (2024). https://doi.org/10.1007/s00134-024-07440-5
Received:
Accepted:
Published:
Issue Date: