Liver tissue oxygenation as measured by near-infrared spectroscopy in the critically ill child in correlation with central venous oxygen saturation

  • Neonatal and Pediatric Intensive Care
  • Published:
Intensive Care Medicine Aims and scope Submit manuscript

Abstract

Objective: To evaluate the clinical usefulness of near-infrared spatially resolved spectroscopic quantitative assessment of liver tissue oxygenation for simple, non-invasive estimation of global tissue oxygenation in critically ill neonates and children. Design: Prospective observational clinical study. Setting: A tertiary multidisciplinary neonatal and paediatric intensive care unit (23 beds). Patients: One hundred neonates and children consecutively admitted to the paediatric intensive care unit. Measurements and results: Near-infrared spectroscopic single-point assessment of liver tissue oxygenation index (TOILiver) was compared with global tissue oxygenation as measured by central venous oxygen saturation (SvO2) and derived haemodynamic parameters. Data were compared using linear and multiple regression analysis. Overall correlation between TOILiver and SvO2 was good (r=0.72, p<0.0001). Multivariable regression revealed that SvO2 alone explained 51% of the observed variance of TOILiver. However, our data demonstrated large inter-individual differences between SvO2 and TOILiver values. Conclusion: Near-infrared spatially resolved spectroscopic quantitative measurement of liver tissue oxygenation correlates well with SvO2 in critically ill neonates and children. Large inter-individual SvO2 to TOILiver differences may prevent its use for non-invasive single-point estimation of global tissue oxygenation. Further clinical studies are required to validate the method with other regional and global haemodynamic parameters and to evaluate its clinical use for continuous non-invasive haemodynamic monitoring.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Electronic Publication

Rights and permissions

Reprints and permissions

About this article

Cite this article

Schulz, G., Weiss, M., Bauersfeld, U. et al. Liver tissue oxygenation as measured by near-infrared spectroscopy in the critically ill child in correlation with central venous oxygen saturation. Intensive Care Med 28, 184–189 (2002). https://doi.org/10.1007/s00134-001-1182-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00134-001-1182-5

Navigation