Abstract
While analytical measurements provide the quantitative estimation of the total amount of metals present in a sample, they do not reflect the truly bioavailable fraction of metal which reflects the adverse biological effect. Hence the development of monitoring tools for detecting bioavailable toxic metals has become a priority in environmental monitoring activities. An optical whole-cell biosensor was constructed using the microalga Scenedesmus subspicatus MM1 immobilizing in inorganic silica hydrogels using the sol-gel technique to detect bioavailable Cadmium (Cd2+), Copper (Cu2+) and Zinc (Zn+) in freshwater. Conditions for optimum biosensor performance have been established regarding effective pH range, cell density, exposure time, and storage stability. The optimum response for the biosensor was dependent on the pH of the matrix, cell concentration and exposure time were derived. The biosensor was operational for four weeks. The limit of detection for the algal biosensor was determined as 9.0 × 10−1, 9.1 × 10−1, and 8.8 × 10−1 mg/L for Cd, Cu and Zn, respectively. Whole-cell cell biosensor will be highly useful since it comprises a single microalgal species able to detect the bioavailable content of Cd2+, Cu2+, and Zn2+ in freshwater.
Similar content being viewed by others
References
Antonacci A, Scognamiglio V (2020) Biotechnological advances in the design of algae-based biosensors. Trends Biotechnol 38(3):334–347. https://doi.org/10.1016/j.tibtech.2019.10.005
Antonacci A, Lambreva MD, Arduini F, Moscone D, Palleschi G, Scognamiglio V (2018) A whole-cell optical bioassay for the detection of chemical warfare mustard agent simulants. Sens Actuators B 257:658–665. https://doi.org/10.1016/j.snb.2017.11.020
Belaïdi FS, Farouil L, Salvagnac L, Temple-Boyer P, Séguy I, Heully JL, Alary F, Bedel-Pereira E, Launay J (2019) Towards integrated multi-sensor platform using dual electrochemical and optical detection for on-site pollutant detection in water. Biosens Bioelectron 132:90–96. https://doi.org/10.1016/j.bios.2019.01.065
Chen Z, Song S, Wen Y, Zou Y, Liu H (2016) Toxicity of Cu (II) to the green alga Chlorella vulgaris: a perspective of photosynthesis and oxidant stress. Environ Sci Pollut Res 23(18):17910–17918. https://doi.org/10.1007/s11356-016-6997-2
D’souza SF (2001) Microbial biosensors. Biosens Bioelectron 16(6):337–353. https://doi.org/10.1016/S0956-5663(01)00125-7
Eroglu E, Smith SM, Raston CL (2015) Application of various immobilization techniques for algal bioprocesses. In: Moheimani NR, McHenry MP, de Boer K, Bahri PA (eds) Biomass and biofuels from microalgae, vol 2. Springer, Cham, pp 19–44. https://doi.org/10.1007/978-3-319-16640-7_2
ISO (International Standard Organization) (1989) Water quality – fresh water algal growth inhibition test with Scenedesmums subspicatus and Selenastrum capricornutum, International Standards Organization (ISO) 8692-1989(E), International Organization for Standardization, Geneva, Switzerland, p 5
Jaafari J, Yaghmaeian K (2019) Optimization of heavy metal biosorption onto freshwater algae (Chlorella coloniales) using response surface methodology (RSM). Chemosphere 217:447–455. https://doi.org/10.1016/j.chemosphere.2018.10.205
Jayaraman SK, Rhinehart RR (2015) Modeling and optimization of algae growth. Indus Eng Chem Res 54(33):8063–8071. https://doi.org/10.1021/acs.iecr.5b01635
Khishamuddin NA, Shing WL, Kin CM, Niu VB (2018) Fluorometric response of photosynthetic microorganism consortium as potential bioindicator for heavy metals detection in water. EnvironmentAsia 11(1):80–86. https://doi.org/10.14456/ea.2018.6
Meier P, Zund R (2000) Statistical methods in analytical chemistry, 2nd edn. Wiley, Hoboken, pp 115–118
Megharaj M, Singleton I, McClure NC, Naidu R (2000) Influence of petroleum hydrocarbon contamination on microalgae and microbial activities in a long-term contaminated soil. Arch Environ Contam Toxicol 38:439–445. https://doi.org/10.1007/s002449910058
Moreno-Garrido I (2013) Microalgal immobilization methods. In: Guisan JM (ed) Immobilization of enzymes and cells, vol 1051. Humana Press, Totawa, pp 327–347. https://doi.org/10.1007/978-1-62703-550-7_22
Perullini M, Rivero MM, Jobbágy M, Mentaberry A, Bilmes SA (2007) Plant cell proliferation inside an inorganic host. J Biotechnol 127:542–548. https://doi.org/10.1016/j.jbiotec.2006.07.024
Perullini M, Ferro Y, Durrieu C, Jobbágy M, Bilmes SA (2014) Sol–gel silica platforms for microalgae-based optical biosensors. J Biotechnol 179:65–70. https://doi.org/10.1016/j.jbiotec.2014.02.007
Peterson HG, Nyholm N, Ruecker N (2005) Algal microplate toxicity test suitable for heavy metals. Small-scale freshwater toxicity investigations. Springer, Dordrecht, pp 243–270
Pham TPT, Cho CW, Yun YS (2010) Algal biosensor-based measurement system for rapid toxicity detection. In: Sharma MK (ed) Advances in measurement systems. Intech Open, London, pp 273–288
Podola B, Nowack ECM, Melkonian M (2005) The use of multiple-strain algal sensor chips for the detection and identification of volatile organic compounds. Biosens Bioelectron 19:1253–1260. https://doi.org/10.1016/j.bios.2003.11.015
Prata JC, da Costa JP, Lopes I, Duarte AC, Rocha-Santos T (2019) Effects of microplastics on microalgae populations: a critical review. Sci Total Environ 665:400–405. https://doi.org/10.1016/j.scitotenv.2019.02.132
Rathnayake IVN (2010) Development of whole-cell microbial biosensors to assess the heavy metal bioavailability in the soil environment (Doctoral dissertation)
Rathnayake IVN, Megharaj M, Naidu R (2021) Green fluorescent protein based whole cell bacterial biosensor for the detection of bioavailable heavy metals in soil environment. Environ Technol Innov. https://doi.org/10.1016/j.eti.2021.101785
Roxby DN, Rivy H, Gong C, Gong X, Yuan Z, Chang GE, Chen YC (2020) Microalgae living sensor for metal ion detection with nanocavity-enhanced photoelectrochemistry. Biosens Bioelectron 165:112420. https://doi.org/10.1016/j.bios.2020.112420
Scognamiglio V, Antonacci A, Arduini F, Moscone D, Campos EVR, Fraceto LF, Palleschi G (2019) An eco-designed paper-based algal biosensor for nanoformulated herbicide optical detection. J Hazard Mater 373:483–492. https://doi.org/10.1016/j.jhazmat.2019.03.082
Shitanda I, Takada K, Sakai Y, Tatsuma T (2005) Compact amperometric algal biosensors for the evaluation of water toxicity. Anal Chim Acta 530:191–197. https://doi.org/10.1016/j.aca.2004.09.073
Teo SC, Wong LS (2014) Whole cell-based biosensors for environmental heavy metals detection. Ann Res Rev Biol. https://doi.org/10.9734/ARRB/2014/9472
Tsopela A, Laborde A, Salvagnac L, Ventalon V, Bedel-Pereira E, Séguy I, Temple-Boyer P, Juneau P, Izquierdo R, Launay J (2016) Development of a lab-on-chip electrochemical biosensor for water quality analysis based on microalgal photosynthesis. Biosens Bioelectron 79:568–573. https://doi.org/10.1016/j.bios.2015.12.050
Turemis M, Rodio G, Pezzotti G, Touloupakis E, Johanningmeier U, Bertalan I, Litescu S, Rea G, Giardi MT (2017) A novel optical/electrochemical biosensor for real time measurement of physiological effect of astaxanthin on algal photoprotection. Sens Actuators B 241:993–1001. https://doi.org/10.1016/j.snb.2016.10.115
Żur J, Wojcieszyńska D, Guzik U (2016) Metabolic responses of bacterial cells to immobilization. Molecules 21(7):958. https://doi.org/10.3390%2Fmolecules21070958
Zhao J, Liu Y, Li X, Lu G, You L, Liang X, …, Du Y (2013) Highly sensitive humidity sensor based on high surface area mesoporous LaFeO3 prepared by a nanocasting route. Sens Actuators B 181:802–809. https://doi.org/10.1016/J.SNB.2013.02.077
Acknowledgements
This research was supported by the University of South Australia Presidents Scholarship (UPS) in collaboration with Cooperative Research Centre for Contamination Assessment and Remediation of the Environment (CRC CARE) Australia fellowship.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary Information
Below is the link to the electronic supplementary material.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Rathnayake, I.V.N., Megharaj, M. & Naidu, R. Sol–Gel Immobilized Optical Microalgal Biosensor for Monitoring Cd, Cu and Zn Bioavailability in Freshwater. Bull Environ Contam Toxicol 110, 73 (2023). https://doi.org/10.1007/s00128-023-03709-5
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s00128-023-03709-5