Abstract
Purpose
We report our initial experiences with use of a new technique we developed for implantation of Sonoma Crx intramedullary rod in patients with displaced clavicle fractures.
Methods
A total of 35 patients (mean age 41.82 ± 13.65, male:female ratio = 21:14) having Robinson Types 1b, 2b and 3b displaced midshaft fractures with >2 cm clavicle shortening were included into the study. A single small incision (~1 cm) was made over the anteromedial aspect of the involved clavicle and an appropriate sized intramedullary nail was inserted in reverse (mirror) configuration of that has been suggested by the manufacturer. Functional assessment was made using Constant shoulder and disability of the arm shoulder and hand scoring.
Results
Mean time of operation was 51.20 ± 10.56 min and mean time of fluoroscopy was 2.33 ± 1.12 min. One patient had implant failure 2 months after the operation and was revised to a new implant. Superficial or deep wound infection, hematoma, neurovascular complication, substance irritation or implant failure did not occur. Follow-up ranged from 12 to 45 months (mean 28.5 ± 9.95 months). At the latest follow-up, mean Constant shoulder score was 93.14 ± 4.06 (ranging from 84.00 to 100.00) and mean disability of the arm shoulder and hand score was 3.68 ± 1.73 (ranging from 0.0 to 6.80).
Conclusion
The technique we described herein provided successful procedural outcomes, eliminated the need for deep dissection of the fracture site and reduced the operation time. Further study on larger populations is warranted to confirm these findings.
Similar content being viewed by others
References
Nowak J, Mallmin H, Larsson S. The aetiology and epidemiology of clavicular fractures. A prospective study during a two-year period in Uppsala, Sweden. Injury. 2000;31:350–8.
Van Tassel D, Owens BD, Pointer L. Moriatis Wolf J. Incidence of clavicle fractures in sports: analysis of the NEISS Database. Int J Sports Med. 2014;35:83–6.
van Laarhoven JJ, Ferree S, Houwert RM, Hietbrink F, Verleisdonk EM, Leenen LP. Demographics of the injury pattern in severely injured patients with an associated clavicle fracture: a retrospective observational cohort study. World J Emerg Surg. 2013;8:36.
Postacchini F, Gumina S, De Santis P, Albo F. Epidemiology of clavicle fractures. J Shoulder Elbow Surg. 2002;11:452–6.
Khan LA, Bradnock TJ, Scott C, Robinson CM. Fractures of the clavicle. J Bone Joint Surg Am. 2009;91:447–60.
Riehl JT, Athans BJ, Munro MW, Langford JR, Kupiszewski SJ, Haidukewych GJ, et al. Minimally displaced clavicle fracture after high-energy injury: are they likely to displace? Can J Surg. 2014;57:169–74.
Liu GD, Tong SL, Ou S, Zhou LS, Fei J, Nan GX, Gu JW. Operative versus non-operative treatment for clavicle fracture: a meta-analysis. Int Orthop. 2013;37:1495–500.
Virtanen KJ, Malmivaara AO, Remes VM, Paavola MP. Operative and nonoperative treatment of clavicle fractures in adults. Acta Orthop. 2012;83:65–73.
Lee YS, Lau MJ, Tseng YC, Chen WC, Kao HY, Wei JD. Comparison of the efficacy of hook plate versus tension band wire in the treatment of unstable fractures of the distal clavicle. Int Orthop. 2009;33:1401–5.
Robinson CM. Fractures of the clavicle in the adult. Epidemiology and classification. J Bone Joint Surg Br. 1998;80:476–84.
Assobhi JE. Reconstruction plate versus minimal invasive retrograde titanium elastic nail fixation for displaced midclavicular fractures. J Orthop Traumatol. 2011;12:185–92.
King PR, Ikram A. Lamberts RP The treatment of clavicular shaft fractures with an innovative locked intramedullary device. J Shoulder Elbow Surg. 2014;17:e1–6.
Richardson M, Asadollahi S, Richardson L. Management of acute displaced midshaft clavicular fractures using Herbert cannulated screw: technique and results in 114 patients. Int J Shoulder Surg. 2013;7:52–8.
Wu CL, Chang HC, Lu KH. Risk factors for nonunion in 337 displaced midshaft clavicular fractures treated with Knowles pin fixation. Arch Orthop Trauma Surg. 2013;133:15–22.
Strauss EJ, Egol KA, France MA, Koval KJ, Zuckerman JD. Complications of intramedullary Hagie pin fixation for acute midshaft clavicle fractures. J Shoulder Elbow Surg. 2007;16:280–4.
Mudd CD, Quigley KJ. Gross LB. Clin Orthop Relat Res. 2011;469:3364–70.
Narsaria N, Singh AK, Arun GR, Seth RR. Surgical fixation of displaced midshaft clavicle fractures: elastic intramedullary nailing versus precontoured plating. J Orthop Traumatol. 2014;25:165–71.
Jubel A, Andermahr J, Schiffer G, Tsironis K, Rehm KE. Elastic stable intramedullary nailing of midclavicular fractures with a titanium nail. Clin Orthop Relat Res. 2003;408:279–85.
Lu CC, Liu PC, Huang SH, Hsieh CH, Tien YC, Chien SH. Complications and technical pitfalls of titanium elastic nail fixation for midclavicular fractures. Orthopedics. 2014;37:e377–83.
King R, Ikram A. Intramedullary locked fixation of clavicle shaft fractures-review of early results. Bone Joint J Orthopaedic Proc Suppl. 2013;95:71–71.
Wilson DJ, Weaver DL, Balog TP. Arrington ED Early postoperative failure of a new intramedullary fixation device for midshaft clavicle fractures. Orthopedics. 2013;36:1450–3.
Palmer DK, Husain A, Phipatanakul WP, Wongworawat MD. Failure of a new intramedullary device in fixation of clavicle fractures: a report of two cases and review of the literature. J Shoulder Elbow Surg. 2011;20:1–4.
Payne DE, Wray WH, Ruch DS, Zura RD, Moorman CT. Outcome of intramedullary fixation of clavicular fractures. Am J Orthop (Belle Mead NJ]. 2011;40:E99–104.
King PR, Scheepers S, Ikram A. Anatomy of the clavicle and its medullary canal: a computed tomography study. Eur J Orthop Surg Traumatol. 2014;24:37–42.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. Informed consent was obtained from all individual participants included in the study.
Conflict of interest
Murat Calbiyik, Sinan Zehir and Deniz Ipek declare that they have no conflict of interest.
Rights and permissions
About this article
Cite this article
Calbiyik, M., Zehir, S. & Ipek, D. Minimally invasive implantation of a novel flexible intramedullary nail in patients with displaced midshaft clavicle fractures. Eur J Trauma Emerg Surg 42, 711–717 (2016). https://doi.org/10.1007/s00068-015-0567-z
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00068-015-0567-z