Abstract
The aim of the present study was to investigate a new type of Bayesian one-step late reconstruction method which utilizes a median root prior (MRP). The method favours images which have locally monotonous radioactivity concentrations. The new reconstruction algorithm was applied to ideal simulated data, phantom data and some patient examinations with PET. The same projection data were reconstructed with filtered back-projection (FBP) and maximum likelihood-expectation maximization (ML-EM) methods for comparison. The MRP method provided good-quality images with a similar resolution to the FBP method with a ramp filter, and at the same time the noise properties were as good as with Hann-filtered FBP images. The typical artefacts seen in FBP reconstructed images outside of the object were completely removed, as was the grainy noise inside the object. Quantitatively, the resulting average regional radioactivity concentrations in a large region of interest in images produced by the MRP method corresponded to the FBP and ML-EM results but at the pixel by pixel level the MRP method proved to be the most accurate of the tested methods. In contrast to other iterative reconstruction methods, e.g. ML-EM, the MRP method was not sensitive to the number of iterations nor to the adjustment of reconstruction parameters. Only the Bayesian parameter β had to be set. The proposed MRP method is much more simple to calculate than the methods described previously, both with regard to the parameter settings and in terms of general use. The new MRP reconstruction method was shown to produce high-quality quantitative emission images with only one parameter setting in addition to the number of iterations.
Similar content being viewed by others
References
Herman G.Image reconstruction from projections: the fundamentals of computerized tomography. New York: Academic Press, 1980.
Shepp L, Vardi Y. Maximum likelihood reconstruction for emission tomography.IEEE Trans Med Image 1982; 1: 113–122.
Herman G, Odhner D. Performance evaluation of an iterative image reconstruction algorithm for positron emission tomography.IEEE Trans Med Imag 1991; 10: 336–346.
Veklerov E, Llacer J. Stopping rule for the MLE algorithm based on statistical hypothesis testing.IEEE Trans Med Imag 1987; 6: 313–319.
Chen C, Johnson V, Wong W, Hu X, Metz C. Bayesian image reconstruction in positron emission tomography.IEEE Trans Nucl Sci 1990; 37: 636–641.
Gindi G, Lee M, Rangarajan A, Zubal G. Bayesian reconstruction of functional images using anatomical information as priors.IEEE Trans Med Imag 1993; 12: 670–680.
Green P. Bayesian reconstructions from emission tomography data using a modified EM algorithm.IEEE Trans Med Imag 1990; 9: 84–93.
Hebert T, Leahy R. A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs priors.IEEE Trans Med Imag 1989; 8: 194–202.
Hebert T, Leahy R. Statistic-based MAP image reconstruction from Poisson data using Gibbs priors.IEEE Trans Signal Processing 1992; 40: 2290–2302.
Lalush D, Tsui B. Attenuation and detector response compensations used with Gibbs priors distributions for maximum a posteriori SPECT reconstruction.IEEE Trans Nucl Sci 1992; 39: 1454–1459.
Kaufman L. Maximum likelihood, least squares, and penalized least squares for PET.IEEE Trans Med Imag 1993; 12: 200–214.
Pitas I, Venetsanopoulos A.Nonlinear digital filters: principles and applications. New York: Kluwer Academic, 1990.
Alenius S. Bayesian image reconstruction in positron emission tomography using median root prior. TUT Symposium on Signal Processing '94, 20 May, Tampere, Finland.
Spinks TJ, Jones T, Gilardi MC, Heather JD. Physical performance of the latest generation of commercial positron scanner.IEEE Trans Nucl Sci 1988; 35: 721–725.
Hudson HM, Larkin RS. Accelerated image reconstruction using ordered subsets of projection data.IEEE Trans Med Imag 1994; 13: 601–609.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Alenius, S., Ruotsalainen, U. Bayesian image reconstruction for emission tomography based on median root prior. Eur J Nucl Med 24, 258–265 (1997). https://doi.org/10.1007/BF01728761
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF01728761