Prospective study on the reproducibility of cephalometric landmarks on conventional and digital lateral headfilms

Prospektive Studie zur Reproduzierbarkelt von Referenzpunkten in konventionellen und digitalen seitlichen Fernröntgenaufnahmen

  • Original Contributions
  • Published:
Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie Aims and scope Submit manuscript

Abstract

The introduction of digital X-ray techniques offered a variety of new possibilities for digital image enhancement and exposure reduction. In order to compare the reproducibility of cephalometric landmarks on conventional and digital lateral headfilms 100 digital and 100 conventional lateral headfilms of patients attending our clinic were randomly selected. The digital cephalograms were obtained using storage phosphor plates in standard X-ray cassettes. All X-rays had been taken at 77 kV. For the digital images the mAs settings for conventional images minus 4 mAs were used. Two orthodontists traced each X-ray twice (21 reference points) at an interval of at least 1 week. The tracings were superimposed and the distances between the tracings of identical reference points were registered.

The average reproducibility of cephalometric landmarks was significantly higher on the digitally obtained images, despite a reduction of radiation exposure of 23.7% in the digital images.

Zusammenfassung

Durch die Einführung der digitalen Röntgentechnik haben sich verschiedene neue Möglichkeiten zur Bildbearbeitung und Dosisreduktion ergeben. Um die Lokalisationsgenauigkeit von kephalometrischen Punkten zwischen konventionell und digital erstellten Röntgenaufnahmen zu vergleichen, wurden 100 digitale und 100 konventionelle Fernröntgenseitenaufnahmen randomisiert ausgewählt. Für die digitalen Aufnahmen wurde die digitale Lumineszenzradiographie verwendet. Bei einheitlicher Röhrenspannung (77 kV) konnte das mAs-Produkt gegenüber einer konventionellen Aufnahme jeweils um 4 mAs reduziert werden. Zwei Fachzahnärzte für Kieferorthopädie zeichneten die Bilder per Hand zweimal im Abstand von mindestens sieben Tagen durch. Die beiden Durchzeichnungen wurden überlagert und die Abstände gleicher Punkte in den verschiedenen Auswertungen registriert.

Es konnte gezeigt werden, daß die Lokalisationsgenauigkeit bei dem digitalen Verfahren gleichwertig und teilweise signifikant besser war, obwohl die Dosis bei den digitalen Aufnahmen im Vergleich zu den konventionellen um 23,7% reduziert wurde.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Barenghi A, Mancini EG, Salvato A. Aspects of digital computed radiography with cephalometric applications. In: Athanasiou AE, ed. Orthodontic cephalometry. St. Louis: Mosby-Wolfe, 1995:221–30.

    Google Scholar 

  2. Borg E, Gröndahl HG. On the dynamic range of different X-ray photon detectors in intra-oral radiography. A comparison of image quality in film, charge-coupled device and storage phosphor systems. Dentomaxillofac Radiol 1996;25:82–8.

    Google Scholar 

  3. Bürgin W, Brägger U. Digital imaging. Schweiz Monatsschr Zahnmed 1995:105:104–7.

    Google Scholar 

  4. Dawood R. Digital radiology—a realistic prospect? Clin Radiol 1990;42:6–11.

    Google Scholar 

  5. Deutsche Gesellschaft für Kieferorthopädie. Indikation und Häufigkeit von Röntgenaufnahmen im Rahmen der kieferorthopädischen Therapie. J Orofac Orthop/Fortschr Kieferorthop 1997;58:286–7.

    Google Scholar 

  6. Forsyth DB, Shaw WC, Richmond S, et al. Digital imaging of cephalometric radiographs, Part 2: Image quality. Angle Orthod 1996;66:43–50.

    Google Scholar 

  7. Geelen W, Wenzel A, Gotfredsen E, et al. Reproducibility of cephalometric landmarks on conventional film, hardcopy, and monitor-displayed images obtained by the storage phosphor technique. Eur J Orthod 1998;20:331–40.

    Google Scholar 

  8. Gudden F. Möglichkeiten und Grenzen der digitalen Bildgebung. Röntgenblätter 1984;37:429–32.

    Google Scholar 

  9. Hitz I, Asal M. Digitale Röntgentechnik in der Praxis. Schweiz Monatsschr Zahnmed 1997;107:802–3.

    Google Scholar 

  10. Jäger A, Döler W, Bockermann V, et al. Anwendung digitaler Bildverarbeitungstechniken in der Kephalometrie. Dtsch Zahnärztl Z 1989;44:184–6.

    Google Scholar 

  11. Macri V, Wenzel A. Reliability of landmark recording on film and digital lateral cephalograms. Eur J Orthod 1993;15:137–48.

    Google Scholar 

  12. Miethke RR. Zur Lokalisationsgenauigkeit kephalometrischer Referenzpunkte. Prakt Kieferorthop 1989;3:107–22.

    Google Scholar 

  13. Morritt CRB. Computed radiography: A new approach to plan film imaging. Diagn Imag 1985;7:58–65.

    Google Scholar 

  14. Näslund EB. Cephalometric landmarks with low-dose computed radiography. Dentomaxillofac Radiol 1990;19:91 abstract.

    Google Scholar 

  15. Näslund EB, Krüger M, Persson A, et al. Analysis of low-dose cephalometric radiographs. Dentomaxillofac Radiol 1998;27:136–9.

    Google Scholar 

  16. Ruppenthal T, Fricke B, Sergl HG, et al. Vergleichende Untersuchung zur Möglichkeit der Dosisreduzierung von Fernröntgenseitenaufnahmen. Fortschr Kieferorthop 1992;53:40–8.

    Google Scholar 

  17. Seki K, Okano T. Exposure reduction in cephalography with a digital photostimulable phosphor imaging system. Dentomaxillofac Radiol 1993;22:127–30.

    Google Scholar 

  18. Sonoda M, Takano M, Miyahara J, et al. Computed radiography utilizing scanning laser stimulated luminescence. Radiology 1983;148:833–8.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Thomas Niegel.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hagemann, K., Vollmer, D., Niegel, T. et al. Prospective study on the reproducibility of cephalometric landmarks on conventional and digital lateral headfilms. J Orofac Orthop/Fortschr Kieferorthop 61, 91–99 (2000). https://doi.org/10.1007/BF01300351

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01300351

Key words

Schlüsselwörter

Navigation