Abstract
The most successful digital radiography detectors to date have been storage phosphor plates used in computed radiography (CR). The detector is cheap, has good producibility, and is robust. Direct radiography (DR) systems are being developed based on flat-panel technology. Better image quality is claimed for some DR systems. On the other hand, DR detectors have low producibility and robustness, and a high price. A new CR detector is being developed at Agfa that combines the advantages of CR and DR. It is a storage phosphor plate made up of needle-shaped crystals. The phosphor efficiently converts absorbed x-ray quanta into photostimulable centers for efficient read out. It has a large dynamic range and its emision is efficiently detected with both photomultiplier tube (PMT) and charge coupled device (CCD). It is shown that CR systems based on the new detector offer image quality that matches that of the best DR systems.
Similar content being viewed by others
References
Hillen, W, Eckenbach W, Quadflieg P, et al: Signal-to-noise performance in cesium iodide x-ray fluorescent screens. SPIE Med Imaging 1443:120–131, 1991
Thoms M: Photostimulated luminescence: A tool for the determination of optical properties of defect centers. J Luminescence 60/61:585–587, 1994
Nakazawa M, Morikawa O, Nitta M, et al: Effect of protective layer on resolution properties of photostimulable phosphor detector for digital radiographic system. SPIE Med Imaging 1231:350, 1990
Lubinsky, AR, Whiting BR, Owen JF: Storage phosphor system for computed radiography: Optical effects and detective quantum efficiency (DQE). SPIE Med Imaging 767:167, 1987
Shaw R, Van Metter RL: An analysis of the fundamental limitations of screen-film systems for x-ray detection II, model calculations. SPIE Med Imaging. 454:128, 1984
Dobbins JT III, Ergun DL, Rutz L, et al: DQE(f) of four generations of computed radiography acquisition devices. Med Phys 22:1581, 1995
Siewerdsen JH: Signal, noise, and detective quantum efficiency of a-Si:H flat-panel imagers. Dissertation, University of Michigan, Ann Arbor, MI, 1998
Lee D, Cheung LK, Rodricks BG, et al: Improved imaging performance of a 14×17-in direct radiography system using a Se/TFT detector. Proc SPIE 3336:14, 1998
Granfors PR: Performance characteristics of an amorphous silicon flat panel x-ray imaging detector. SPIE Med Imaging 3659:480, 1999
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Leblans, P., Struye, L. & Willems, P. A new needle-crystalline computed radiography detector. J Digit Imaging 13 (Suppl 1), 117–120 (2000). https://doi.org/10.1007/BF03167640
Issue Date:
DOI: https://doi.org/10.1007/BF03167640