A new needle-crystalline computed radiography detector

  • SESSION 3B: Digital Imaging and Computer-Aided Diagnosis
  • Published:
Journal of Digital Imaging Aims and scope Submit manuscript

Abstract

The most successful digital radiography detectors to date have been storage phosphor plates used in computed radiography (CR). The detector is cheap, has good producibility, and is robust. Direct radiography (DR) systems are being developed based on flat-panel technology. Better image quality is claimed for some DR systems. On the other hand, DR detectors have low producibility and robustness, and a high price. A new CR detector is being developed at Agfa that combines the advantages of CR and DR. It is a storage phosphor plate made up of needle-shaped crystals. The phosphor efficiently converts absorbed x-ray quanta into photostimulable centers for efficient read out. It has a large dynamic range and its emision is efficiently detected with both photomultiplier tube (PMT) and charge coupled device (CCD). It is shown that CR systems based on the new detector offer image quality that matches that of the best DR systems.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Hillen, W, Eckenbach W, Quadflieg P, et al: Signal-to-noise performance in cesium iodide x-ray fluorescent screens. SPIE Med Imaging 1443:120–131, 1991

    Google Scholar 

  2. Thoms M: Photostimulated luminescence: A tool for the determination of optical properties of defect centers. J Luminescence 60/61:585–587, 1994

    Article  Google Scholar 

  3. Nakazawa M, Morikawa O, Nitta M, et al: Effect of protective layer on resolution properties of photostimulable phosphor detector for digital radiographic system. SPIE Med Imaging 1231:350, 1990

    CAS  Google Scholar 

  4. Lubinsky, AR, Whiting BR, Owen JF: Storage phosphor system for computed radiography: Optical effects and detective quantum efficiency (DQE). SPIE Med Imaging 767:167, 1987

    Google Scholar 

  5. Shaw R, Van Metter RL: An analysis of the fundamental limitations of screen-film systems for x-ray detection II, model calculations. SPIE Med Imaging. 454:128, 1984

    CAS  Google Scholar 

  6. Dobbins JT III, Ergun DL, Rutz L, et al: DQE(f) of four generations of computed radiography acquisition devices. Med Phys 22:1581, 1995

    Article  PubMed  Google Scholar 

  7. Siewerdsen JH: Signal, noise, and detective quantum efficiency of a-Si:H flat-panel imagers. Dissertation, University of Michigan, Ann Arbor, MI, 1998

    Google Scholar 

  8. Lee D, Cheung LK, Rodricks BG, et al: Improved imaging performance of a 14×17-in direct radiography system using a Se/TFT detector. Proc SPIE 3336:14, 1998

    Article  Google Scholar 

  9. Granfors PR: Performance characteristics of an amorphous silicon flat panel x-ray imaging detector. SPIE Med Imaging 3659:480, 1999

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Paul Leblans.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Leblans, P., Struye, L. & Willems, P. A new needle-crystalline computed radiography detector. J Digit Imaging 13 (Suppl 1), 117–120 (2000). https://doi.org/10.1007/BF03167640

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03167640

Keywords

Navigation