Abstract

Tissue velocity information (TVI) is acquired by sampling of tissue Doppler velocity values at discrete points. The information is stored in an interfoiled format with gray scale imaging during one or several cardiac cycle at a high temporal resolution, > 60 Hz, giving signals that tolerate mathematical processing as derivation, integration and Fourier analysis of velocity profiles without distortions. The software enables the possibility to analyze multiple velocity profiles from any localization within the acquired scanned sector. The myocardial tissue velocity direction and color-coded numerical value can be computed along any chosen curve form (C-line) and be presented as a spatial function of velocities against time (C-mode). The velocity curves can also be presented in several new functional modes as color-coded running cineloops: phase imaging, time delay imaging, amplitude imaging, acceleration imaging, instantaneous phase imaging, wrapped phase imaging.

The software also allows color or C-mode presentation of tissue contraction and expansion. This facilitates the differentiation between active and passive myocardial tissue movements, thus improving the ability to differentiate between healthy and diseased myocardial tissue. This article presents several applications of the software in normals and in cardiac patients.

Zusammenfassung

Die Gewebe-Doppler-Echokardiographie zeichnet die Geschwindigkeit in einem ausgewählten Aufnahmefenster auf. Die Signale werden gleichzeitig mit dem Grauwertbild für einen oder mehrere Herzzyklen mit hoher zeitlicher Auflösung (mehr als 60 Hz) registriert, so daß mathematische Manipulationen einschließlich Integration und Fourier-Analyse der Geschwindigkeitsprofile ohne Fehler möglich sind. Die Programmierung erlaubt die Analyse multipler Geschwindigkeitsprofile von jeder Lokalisation innerhalb eines bestimmten Schallsektors.

Die Geschwindigkeit des Myckards und die farbkodierten numerischen Werte können entlang beliebigen Kurvenformen (C-Linie) aufgezeichnet und in einer räumlichen Funktion der Geschwindigkeit gegen die Zeit aufgetragen werden. Die Geschwindigkeitskurven können in verschiedenen neuen Funktionsarten als farbkodierte Filmszenen dargestellt werden: Phasenbild, gefiltertes Phasenbild etc.

Die Programmierung erlaubt die Abbildung in Farbe oder als C-Bild-Präsentation der Gewebekontraktion und Dehnung. Dadurch ist die Differenzierung zwischen aktiven und passiven Myokardbewegungen möglich, so daß zwischen erkranktem und gesundem Myokard unterschieden werden kann. Dieser Beitrag stellt verschiedene Anwendungen der Software bei Normalpersonen und Patienten vor.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Hecht HS, Taylor R, Wong M. Comparative evaluation of segmental asynergy in remote myocardial infarction by radionuclide angiography, two-dimensional echocardiography and contrast ventriculography. Am Heart J 1981;101:740–4.

    Article  PubMed  CAS  Google Scholar 

  2. Henze E, Tymiec D, Delagardelle C. Specification of regional wall motion abnormalities by phase analysis of radionuclide angigrams in coronary artery disease and non coronary artery disease patients. J Nucl Med 1986;27:751–6.

    Google Scholar 

  3. Isaaz K, Thomson A, Ethevenot G, et al. Doppler echocardiographic measurement of low velocity motion of left ventricular posterior wall. Am J Cardiol 1989;64:66–75.

    Article  PubMed  CAS  Google Scholar 

  4. McDicken W, Sutherland G, Moran C, et al. Color Doppler velocity imaging of the myocardium. Ultrasound Med Biol 1992;18:651–4.

    Article  PubMed  CAS  Google Scholar 

  5. Sutherland GR, Stewart MJ, Groundstroem KWE, et al. Colour Doppler myocardial imaging: a new technique for the assessment of myocardial function. J Am Soc Echocardiogr 1994;7:441–58.

    PubMed  CAS  Google Scholar 

  6. Uematsu M, Miyatake K, Tanaka N. Myocardial velocity gradient as a new indicator of regional left ventricular contraction: Detection a two-dimensional tissue Doppler imaging technique. J Am Coll Cardiol 1995;26:217–23.

    Article  PubMed  CAS  Google Scholar 

  7. Underwood SR, Walton S, Laming PJ. Quantitative phase analysis in the assessment of coronary artery disease. Br Heart J 1980;61:14–7.

    Article  Google Scholar 

  8. Zamorano J, Wallbridge D, Ge J, et al. Assessment of cardiac physiology by tissue Doppler echocardiography. A comparison with invasive haemodynamics. Eur Heart J 1997;18:330–9.

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Lars-Åke Brodin MD, PhD.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Brodin, LÅ., van der Linden, J. & Olstad, B. Echocardiographic functional images based on tissue velocity information. Herz 23, 491–498 (1998). https://doi.org/10.1007/BF03043756

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03043756

Schlüsselwörter

Key Words

Navigation