Abstract
Self-report is a frequently-used method of assessing compliance with prescribed medications in patients with chronic illnesses. Most researchers agree, however, that self-report misrepresents patient adherence to regimen prescription. In this randomized, controlled study evaluating inhaler medication compliance, diary data was compared to electronic monitoring in 55 adults with asthma. Subjects randomized to the treatment group received a six-week self-management program. An electronic monitor, the MDI Chronolog, was used in this study to assess inhaler use. The MDI Chronolog records the date and time of each inhaled activation. The self-report measure used was a daily asthma diary. Subjects were asked to use their inhaled medications as usual and record the date and time they administered their medication over a one-week period.
Moderate correlations (rs=.55, Mdnd=95.8, Mdnc=91.6) were found when comparing the number of administrations calculated using the MDI Chronolog to the number of administrations reported in the subject’s diary. When the dosing interval was examined, however, the correlation was weaker (rs=.44, Mdndiary=92.8, Mdnchronolog=37.5). In each case, self-reported compliance was higher than monitored adherence.
Similar content being viewed by others
References
Dunbar J, Dunning EJ, Dwyer K: Compliance measurement with arthritis regimen.Arthritis Care and Research. 1989,2(3):s8-s16.
Rand CS, Wise RA: Measuring adherence to asthma medication regimens.American Review of Respiratory and Critical Care Medicine. 1994,149:289–290.
Editorial. Are you taking your medicine?Lancet. 1990,335:262–263.
Tashkin DP, Rand C, Nides M, et al: A Nebulizer Chronolog to monitor compliance with inhaler use.The American Journal of Medicine. 1991,91:33s-36s.
Spector SL, Kinsman R, Mawhinney H, et al: Compliance of patients with asthma with an experimental aerosolized medication: Implications for controlled clinical trials.Journal of Allergy and Clinical Immunology. 1986,77:65–70.
Gong H, Simmons M, Clark V, Tashkin D: Metered dose inhaler usage in subjects with asthma: Comparison of Nebulizer Chronolog and daily diary record information.Journal of Allergy and Clinical Immunology. 1988,82:5–10.
Mawhinney H, Spector S, Kinsman R, et al: Compliance in clinical trials of two non-bronchodilators, antiasthma medications.Annals of Allergy. 1991,66:294–299.
Milgrom H, Bender B, Ackerson L, et al: Non-compliance and treatment failure in children with asthma.Journal of Allergy and Clinical Immunology. 1996,98:1051–1057.
Rand CS, Wise RA, Nides M, et al: Metered dose inhaler adherence in a clinical trial.American Review of Respiratory Disease. 1992,146:1559–1564.
Nides MA, Tashkin DP, Simmons MS et al: Improving inhaler adherence in a clinical trial through the use of the Nebulizer Chronolog.Chest. 1993,104:501–507.
National Asthma Education Program Expert Panel.Executive Summary: Guidelines for the Diagnosis and Management of Asthma, DHHS Publication No. 91-3042A. Bethesda, MD: National Institutes of Health, 1991.
Pocock SL:Clinical Trials: A Practical Approach. New York: John Wiley & Sons, 1983.
Rudy EB, Vaska PL, Daly BJ, Happ MB, Shiao P: Permuted block design for randomization in a nursing clinical trial.Nursing Research. 1993,42:287–289.
Creer TS, Kotses H, Reynolds RVC: Living with asthma: Part II beyond CARIH.Journal of Asthma. 1989,26:31–52.
Coutts JAP, Gibson NA, Paton JY: Measuring compliance with inhaled medication in asthma.Archives of Diseases in Children. 1992,67:332–333.
Author information
Authors and Affiliations
Additional information
Preparation of this manuscript was supported in part by NINR grant #5-F31NR06787-02 and Glaxo Pharmaceutical grant #NUR005.
About this article
Cite this article
Berg, J., Dunbar-Jacob, J. & Rohay, J.M. Compliance with inhaled medications: The relationship between diary and electronic monitor. ann. behav. med. 20, 36–38 (1998). https://doi.org/10.1007/BF02893807
Issue Date:
DOI: https://doi.org/10.1007/BF02893807