Abstract
An appropriate hemostatic dressing for prehospital use should lower mortality due to uncontrolled hemorrhage. In this study, the investigators explored the hemostatic effects of Microporous Polysaccharide Hemosphere® (MPH) applied in a rat model with severe femoral artery bleeding. Twelve rats were randomly assigned to MPH and control groups: The femoral artery of each rat was pierced to initiate bleeding. Then, 0.25 g MPH was poured into the bleeding site. A 200-g scale weight was placed over the bleeding site for 30 sec. At 30-sec intervals, the scale weight was removed, and hemostasis was assessed visually. After 30 sec, if the bleeding had ceased, the test was scored and checked as “passed at 30 sec.” If the bleeding had not stopped, the same procedures were repeated a maximum of 3 times. If hemostasis could not be achieved even after the third application, the test was scored as failed. The same sequence of procedures was repeated for the control group without use of MPH and with only standard compression. Application of MPH resulted in complete control of bleeding in 2 of 6, 4 of 6, and 6 of 6 rats at 30, 60, and 90 sec, respectively. In the control group, however, hemostasis could not be achieved in all 6 rats, even at 90 sec. The difference between the 2 groups was statistically significant (P=.007). Application of MPH and compression with a scale weight significantly decreased the time of hemostasis in the rat model with femoral arterial bleeding.
Similar content being viewed by others
References
Alam HB, Chen Z, Jaskille A. Application of a zeolite haemostatic agent achieves 100% survival in a lethal model of complex groin injury in swine.J Trauma. 2004; 56: 974–983.
Alam HB, Uy GB, Miller D, Koustova E. Comparative analysis of haemostatic agents in a swine model of lethal groin injury.J Trauma. 2003; 54: 1077–1082.
King DR, deMoya MM, McKenney MG, Cohn SM. Modified rapid deployment hemostat terminates from hepatic rupture in third trimester.J Trauma. 2006; 61: 739–742.
Ereth MH, Dong Y, Gordon EA, Oliver WC. Microporous polysaccharide hemispheres provide effective topical hemostasis in a human modified bleeding time incision model. Presented at: Annual Meeting of the American Society of Anesthesiology; October 12–16, 2002; Orlando, Fla.
Medafor, Inc. Evaluation of Hemadex clotting beads in direct contact with acute arterial hemorrhage in the rabbit protocol. Available at: http://www.medafor.com/home.html. Accessed on January 29, 2007.
Wedmore I, McManus JG, Pusateri AE, Holcomb JB. A special report on the Chitosan-based hemostatic dressing: experience in current combat operations.J Trauma. 2006; 60: 655–658.
Ahuja N, Ostomel TA, Rhee P, et al. Testing of modified zeolite hemostatic dressings in a large animal model of lethal groin injury.J Trauma. 2006; 61: 1312–1320.
Neuffer MC, McDivitt J, Rose D, King K, Cloonan CC, Vayer JS. Homeostatic dressings for the first responder: a review.Milit Med. 2004; 169: 716–720.
Pusateri AE, Holcomb JB, Kheirabadi BS, Alam HB, Wade CE, Ryan KL. Making sense of the preclinical literature on advanced hemostatic products.J Trauma. 2006; 60: 674–682.
Sondeen JL, Pusateri AE, Coppes VG, Gaddy CE, Holcomb JB. Comparison of 10 different hemostatic dressings in an aortic injury.J Trauma. 2003; 54: 280–285.
Walters T, Baer DG, Kauvar DS. A large animal fatal extremity hemorrhage model and evaluation of a polymeric dressing (fatal extremity hemorrhage).J Trauma. 2006; 61: 1107–1112.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ersoy, G., Kaynak, M.F., Yilmaz, O. et al. Hemostatic effects of Microporous Polysaccharide Hemosphere® in a rat model with severe femoral artery bleeding. Adv Therapy 24, 485–492 (2007). https://doi.org/10.1007/BF02848770
Issue Date:
DOI: https://doi.org/10.1007/BF02848770