Abstract
The fatigue fracture of commercially pure (cp) titanium tubes at relatively low temperatures [120° C (250° F)] in a shell-and-tube heat exchanger was studied. The cp titanium tubes were subjected to flow-induced vibration and compression axial loading in service. The combined stresses resulted in numerous intergranular cracks in circumferential direction. Some cracks reached a size that resulted in complete rupture of tubes. Fractographic analyses indicated that the fracture was caused by high-cycle fatigue. A large portion of the tube wall indicated a lack of characteristic ductility of cp titanium. The reduced ductility was a result of second-phase particle inclusion and hydrogen absorption in tube material. The secondphase particles provided easy sites for initiation and coalescence of microvoids. Hydrogen absorption of titanium resulted in an increase in hydride content and thus a decrease in ductility.
Similar content being viewed by others
References
Chenoweth, J.M.,Flow-Induced Vibration, Heat Exchanger Design Handbook, 4. 6. 1–1 (1983).
Kissel, J.H.,Machine Design, 104–107(1973).
Hayashi, K., Proceedings of the 3rd International Conference on Pressure Vessels Technology, 363–373 (1977).
TIMET,Titanium for Refinery Use, 3 (1984).
Lunde, L. and K. Videm,Growing Use of Titanium in Offshore Industry, Offshore Goteborg, 38. 4–38.5 (1981).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Hsu, C.H. Fatigue cracking of titanium tubes in an industrial heat exchanger. J. Mater. Eng. 10, 57–60 (1988). https://doi.org/10.1007/BF02834114
Issue Date: