Skip to main content
Log in

Instrumentation for PSD-based neutron diffractometers at Dhruva reactor

  • Published:
Pramana Aims and scope Submit manuscript

Abstract

Linear position sensitive detectors (PSDs) are widely used to configure neutron diffractometers and other instruments. Necessary front-end electronics and a data acquisition system [1] is developed to cater to such instruments built around the Dhruva research reactor in BARC. These include three diffractometers with multiple PSDs and four with single PSD. The front-end electronics consists of high voltage units, preamplifiers [2],shaping amplifiers, ratio ADCs (RDC) [3]. The data acquisition system consists of an interface card and software. Commercially available hardware like temperature controller or stepper motor controller connected over GPIB or RS232 are also integrated in the data acquisition system. The data acquisition is automated so that it can continue unattended for control parameter like temperature, thus enabling optimum utilization of available beam time. The instrumentation is scalable and can be easily configured for various instrumental requirements. The front-end electronics and the data acquisition system are described here.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. S S Pande, S P Borkar, A Behere and M D Ghodgaonkar,Proceedings of Symposium on Intelligent Nuclear Instrumentation (INIT 2001), 2001, p. 53

  2. P K Mukhopadhyay and P Shenoy,Proceedings of the Symposium on Advanced Instrumentation for Nuclear Research (SAINAR), 1993, p. L2-1

  3. P K Mukhopadhyay, P Shenoy, V B Chandratre and K R Gopalkrishnan,Proceedings of the DAE Symposium on Nuclear Physics, 1992,35B, p. 458

    Google Scholar 

  4. S K Paranjpe and Y D Dande,Pramana -J. Phys. 32, 793 (1989)

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Pande, S.S., Borkar, S.P., Prafulla, S. et al. Instrumentation for PSD-based neutron diffractometers at Dhruva reactor. Pramana - J Phys 63, 459–463 (2004). https://doi.org/10.1007/BF02705016

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02705016

Keywords

PACS No.

Navigation