Abstract
The extent to which extravascular lung water (EVLW) is dependent on cardiac output was analysed in anaesthetized and mechanically ventilated pigs. EVLW was measured by thermal-dye dilution technique, by a fibreoptic thermistor catheter system (system 1), and by a thermistor catheter-external optical cuvette system (system 2). During baseline conditions, at which cardiac output was 3.65 l/min, EVLW was 11.7 and 7.7 ml/kg b.w. with systems 1 and 2 respectively. A reduction of cardiac output to a mean of 1.90 l/min by the addition of halothane to the inspired gas did not significantly affect EVLW with system 1 (−5%) but increased EVLW by 39% (p<0.05) with system 2. An increase of cardiac output to a mean of 4.78 l/min by intravenous infusion of isoproterenol caused a small increase in EVLW with system 1 (14%;p<0.05) and a decrease with system 2 (10%;p<0.05). The dependence on cardiac output was the same whether the catheters were positioned centrally (aortic root) or peripherally (abdominal aorta). With system 1 the CO dependence was due to different time constants in thermistor and optical systems, and with appropriate phasing the dependence could be eliminated. With system 2 a large overestimation of the mean transit time difference between the two indicators was seen when cardiac output was low, resulting in overestimation of EVLW. It is concluded that the dependence of EVLW volume on cardiac ouptut is an artefact due to technical problems in the design of the recording equipment rather than a reflection of pulmonary or vascular effects.
Article PDF
Similar content being viewed by others
References
Staub NC, Hogg JC (1980) Conference report of a workshop on the measurement of lung water. Crit Care Med 8:752–759
Noble WH, Severinghaus JW (1972) Thermal and conductivity dilution curves for rapid quantitation of pulmonary edema. J Appl Physiol 32:770–775
Lewis FR, Elings VB, Hill SL, Christensen JM (1982) The measurement of extravascular lung water by thermal-green dye indicator dilution. Ann NY Acad Sci, 394–410.
Goodwin CW Jr, Pruitt BA Jr (1982) Underestimation of thermal lung water volume in patients with high cardiac output. Surgery 92:401–408
Fallon KD, Drake RE, Laine GA, Gabel JC (1985) Effect of cardiac output on extravascular lung water estimates made with the Edwards lung water computer. Anesthesiology 62:505–508
Pfeiffer U, Aschenbernner G, Blümel G (1982) The system for quantitating thermal-dye extravascular lung water. In: Prakash O (ed) Computers in critical care and pulmonary medicine. Plenum, London, pp 123–125
Frostell C, Blomquist H, Wickerts CJ (1987) Effects of PEEP on extravascular lungwater and central blood volume in the dog. Acta Anaesthesiol Scand 31:711–716
Pfeiffer U, Birk M, Aschenbrenner G, Petrowicz O, Blümel G (1980) Validity of the thermo-dye-technique for measurement of extravascular lung water. Eur Surg Res 12:106–107
Author information
Authors and Affiliations
Additional information
This study was supported by grants from the Swedish Medical Research Council (grant no. 5315), the Laerdal Foundation and the Swedish Medical Association
Rights and permissions
About this article
Cite this article
Wickerts, C.J., Jakobsson, J., Frostell, C. et al. Measurement of extravascular lung water by thermal-dye dilution technique: mechanisms of cardiac output dependence. Intensive Care Med 16, 115–120 (1990). https://doi.org/10.1007/BF02575305
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02575305