A new electromechanical method for measuring intraocular pressure

  • Published:
Documenta Ophthalmologica Aims and scope Submit manuscript

Abstract

A new electromechanical method to measure intraocular pressure is presented. A light probe was made to collide with an eye (cornea or sclera) and to bounce back. The impact was registered by an acceleration sensor or the duration of contact with the eye was measured using the phenomenon of the electrical conductivity of biological objects. Laboratory experiments were carried out using pig eyes pressurized with water leveled to different heights. Preliminary clinical trials were carried out comparing the values obtained with those of the Goldmann applanation tonometer. The time of contact and the deceleration time decreases and the deceleration maximum increases in proportion with IOP. A new kind of tonometer can be constructed based on this principle. Measurement can be performed to cornea or sclera without an anesthetic drop. Further study is required to evaluate the accuracy and usefulness of this method.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Abbreviations

ADC:

analog to digital converter

g:

the earth's gravitation force (9.8 m/s2)

IOP:

intracular pressure

References

  1. Forbes M, Pico G, Grolman B. A non-contact applanation tonometer. Arch Ophthalmol 1974; 91: 134–40.

    PubMed  CAS  Google Scholar 

  2. Goldmann H, Schmidt TH, Über Applanations-tonometrie. Ophthalmologica 1957; 134: 221–242.

    PubMed  CAS  Google Scholar 

  3. Mackay RS, Marg E. Fast, automatic, electronic tonometers based on an exact theory. Acta Ophtalmol 1959; 37: 495–507.

    CAS  Google Scholar 

  4. Gräf M, Wassill H, Burkhard D. Ein neues lageunabhängiges Tonometer (Proton) im Vergleich mit dem Goldmann-applanationstonometer. Klin Monatsbl Augenheilkd 1995; 206: 255–261.

    Article  PubMed  Google Scholar 

  5. Minckler DS, Baerveldt G, Heuer DK et al. Clinical evaluation of the Oculab Tono-Pen. Am J Ophthalmol 1987; 104: 168–173.

    PubMed  CAS  Google Scholar 

  6. Fisher JH, Watson PG, Spaeth G. A new handheld air impulse tonometer. Eye 1988; 2: 238–242.

    PubMed  Google Scholar 

  7. Irvine AR, Kaufman FE, Intraocular pressure following penetrating keratoplast, Am J Ophthalmol 1969; 68: 835–844.

    PubMed  CAS  Google Scholar 

  8. Goethals M, Missotten L. Intraocular pressure in children up to five years of age. J Pediatr Ophtalmol Strab. 1983; 20: 49–51.

    CAS  Google Scholar 

  9. Wright MM, Grajewski AL. Measurement of intraocular pressure with flat anterior chamber. Ophthalmology 1991; 98: 1854–1857.

    PubMed  CAS  Google Scholar 

  10. Badouin C, Gastaud P. Influence of topical anesthesia on tonometric values of intraocular pressure. Ophthalmologica 1994; 208: 309–313.

    Article  Google Scholar 

  11. Schottenstein EM. Intraocular pressure and tonometry. In: Ritch R, Shields MP, Krupin T. eds. The Glaucomas vol I, 1996, chap. 20 p. 420.

  12. Roth W, Blake DG. Vibration tonometry-principles of the vibra-tonometer. J Am Optom Assoc 34: 971–974, 1963.

    Google Scholar 

  13. Greene PR. Mechanical considerations in myopia: relative effects of accomocation, convergence, intraocular pressure, and the extraocular muscles. Am J Optom Physiol Opt 1980; 57: 902–914.

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Antti Kontiola.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Kontiola, A. A new electromechanical method for measuring intraocular pressure. Doc Ophthalmol 93, 265–276 (1997). https://doi.org/10.1007/BF02569066

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02569066

Key words

Navigation