Skip to main content
Log in

Efficacy and safety of digital subtraction angiography with special reference to contrast agents

  • Commentary
  • Published:
CardioVascular and Interventional Radiology Aims and scope Submit manuscript

Abstract

We evaluated the diagnostic accuracy and complications of digital subtraction angiography (DSA) in a series of clinical trials conducted on patients primarily with cerebral vascular disease and those evaluated before and after surgery or percutaneous transluminal angioplasty. Doubleblind studies of the carotid-vertebral arteries of 300 of the 2,200 patients using DSA imaging and a variety of ionic and nonionic contrast agents showed that although subjects tolerated the injection of nonionic contrast better than ionic, nonionic contrast administration did not lead to better image quality. Of 764 patients receiving ionic contrast media, 3.3% had mild-to-severe adverse reactions; of 350 injected with nonionic contrast agents, 1.7% had mild-to-severe adverse reactions. If the sole consideration is safety, use of ionic contrast media is justified.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Mistretta CA, Crummy AB, Strother CM, Sackett JF (eds) (1982) Digital subtraction arteriography: An application of computerized fluoroscopy. Year Book Medical Publishers New York Chicago London

    Google Scholar 

  2. Pond GD, Smith JRL, Hillmann BJ, Ovitt TW, Capp MP (1981) Current clinical applications of clinical subtraction angiography. Appl Radiol (Nov/Dec) 71–79

    Google Scholar 

  3. Rapoport S, Bookstein JJ, Higgins CB, Carey PH, Sovak I, Lasser EC (1982) Experiences with metrizamide in patients with previous severe anaphylactoid reactions to ionic contrast agents. Radiology 143:321–325

    PubMed  CAS  Google Scholar 

  4. Sackett JF, Mann FA (1982) Contrast media for digital subtraction arteriography of cerebral arteries. In: CA Mistretta, AB Crummy, CM Strother, JF, Sackett (eds) Digital subtraction arteriography. An application of computerized fluoroscopy. Year Book Medical Publishers, New York Chicago London, p 23

    Google Scholar 

  5. Seyferth W, Dilbat G, Herde R, Marhoff P, Zeitler E (1982) Digitale Subtraktionsangiographie (DSA) an einem konventionellen Röntgendurchleuchtungsgerät (in German und English). Electromedica 4:120–123

    Google Scholar 

  6. Seyferth W, Marhoff P, Zeitler E (1982) Transvenöse und arterielle digitale Videosubtraktionsangiographie (DVSA). ROEFO 136:301–309

    CAS  Google Scholar 

  7. Seyferth W, Marhoff P, Zeitler E (1982) Digitale Subtraktionsangiographie: Diagnostischer Stellenwert und Risiko (in German and English). Electromedica 2:60–68

    Google Scholar 

  8. Seyferth W, Dilbat G, Marhoff P, Zeitler E (1982) Digitale Subtraktionsangiographie—diagnostische Bereicherungen oder technische Spielerei? Standortbestimmung und Ausblick. Herz+Gefäße 2:742–757

    Google Scholar 

  9. Stieghorst MF, Strother CM, Mistretta CA, Crummy AG (1981) Digital subtraction angiography—A clinical overview. Appl Radiol (Nov/Dec) 43–49

    Google Scholar 

  10. Schweiger H, Raithel D, Seyferth W, Zeitler E (1982) Möglichkeiten der digitalen Angiographie nach rekonstruktiven Eingriffen am Gefäßsystem. In: Denck H, Hagmüller GW, Brunner U (eds) Arterielle Durchblutungsstörungen der unteren Extremitäten „Grenzzonen der Therapieentscheidung” TM-Verlag, Bad Oeynhausen

    Google Scholar 

  11. Weinstein MA, Modic NT, Buonocore E, Meaney TF (1981) Digital subtraction angiography. Clinical experience of the Cleveland Clinic Foundation. Appl Radiol (Nov/Dec) 53–69

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Seyferth, W., Dilbat, G. & Zeitler, E. Efficacy and safety of digital subtraction angiography with special reference to contrast agents. Cardiovasc Intervent Radiol 6, 265–270 (1983). https://doi.org/10.1007/BF02552447

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02552447

Key words

Navigation