Skip to main content
Log in

Direct measured systolic pressure gradients across the aorto-iliac segment in multiple-level-obstruction arteriosclerosis

  • Published:
CardioVascular and Interventional Radiology Aims and scope Submit manuscript

Abstract

Patients with severe ischemia due to multilevel obstructions in the leg arteries both above and below the groin were assessed preoperatively by intraarterial brachial and femoral artery pressure measurements. The systolic pressure drop along aortoiliac obstructions was compared to the angiographic findings. A consistent pressure gradient was found in the various types of arterial occlusions.

In patients with occlusion of both the aorta and the iliac arteries, the systolic pressure drop was about 60% (range, 50–78%, SD 9%). The various types of iliac artery occlusions resulted in quite uniform systolic pressure drops of about 50% (range 35–68%, SD 9%). In contrast, the systolic pressure drop along different types of iliac stenoses showed a wide variation, ranging from a minimal drop to about 60%. The degree of stenosis on the angiogram was correlated significantly with the pressure drop. Due to large variations, however, this angiographic information was found to be useless in the individual patient. No difference in the pressure drop was found between cases in which rich and poor collateral networks were visualized.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Castaneda-Zuniga W, Knight L, Formanek A, Moore R, D'Souza V, Amplatz K (1976) Hemodynamic assessment of obstructive aortoiliac disease. AJR 127:559–561

    PubMed  CAS  Google Scholar 

  2. Faris IB, Jamieson CW (1975) The diagnosis of aortoiliac stenosis: A comparison of thigh pressure measurement and femoral artery flow velocity profile. J Cardiovasc Surg 16:597–602

    CAS  Google Scholar 

  3. Noer I, Tønnesen KH, Sager Ph (1978) Preoperative estimation of run off in patients with multiple level arterial obstructions as a guide to partial reconstructive surgery. Ann Surg 5:663–665

    Article  Google Scholar 

  4. Quin RO, Evans DH, Bell PRF (1975) Haemodynamic assessment of the aorto-iliac segment. J Cardiovasc Surg 16:586–589

    CAS  Google Scholar 

  5. Sako Y (1966) Papaverine test in peripheral arterial disease. Surg Forum 17

  6. Udoff EJ, Barth KH, Harrington DP, Kaufman SL, White RI (1979) Hemodynamic significance of iliac artery stenosis: Pressure measurements during angiography. Radiology 2:289–293

    Google Scholar 

  7. Zeitler E (1978) Dilatation technique of iliac artery stenosis with balloon catheters. In: Percutaneous vascular recanalization, Zeitler E, Grüntzig A, Schoop W (eds) Springer, Berlin Heidelberg New York, pp 24–31

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Noer, I., Præstholm, J. & Tønnesen, K.H. Direct measured systolic pressure gradients across the aorto-iliac segment in multiple-level-obstruction arteriosclerosis. Cardiovasc Intervent Radiol 4, 73–76 (1981). https://doi.org/10.1007/BF02552379

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02552379

Key words

Navigation