Noise of surface bio-potential electrodes based on NASICON ceramic and Ag−AgCl

  • Sensors
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

The electrochemical noise from dry NASICON-based surface electrodes and pregelled Ag−AgCl electrodes is evaluated in saline solutions and on the skin. The electrochemical noise from the electrode/electrolyte interface is found to be negligible (less than 1 μV peak to peak). On the skin, the noise level is highly dependent on the patient. At high frequencies, the skin/electrode interface noise is equal to ‘thermal noise’ and can be related to the real part of the skin/electrode impedance. At low frequencies (f<100 Hz), excess noise is observed that varies as f−2. It is tentatively ascribed to a non-stationary process or noise of electrochemical origin due to the ionic nature of the skin. The contribution of residual EMG signal of low amplitude (5 μV peak to peak) is suggested for electrodes with large surface area.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Barker, G. C. (1969): ‘Noise connected with electrode processes’,J. Electroanal. Chem.,21, pp. 127–136

    Article  Google Scholar 

  • Blanc, G., Gabrielli, C., andKeddam, M. (1993): ‘Fluctuations in electrochemical systems. I. General theory on diffusion limited electrochemical reactions’,J. Chem. Phys.,99, pp. 7372–7239

    Google Scholar 

  • Callen, H. B., andWelton, T. A. (1951): ‘Irreversibility and generalized noise’,Phys. Rev.,83, pp. 34–40

    Article  MATH  MathSciNet  Google Scholar 

  • De Vries, H. A., Burke, R. K., Hopper, R. T., andSloan, J. H. (1976): ‘Relationship of resting EMG level to total body metabolism with reference to the origin of tissue noise’,Am. J. Phys. Med.,5, 585–590

    Google Scholar 

  • Ferenandez, M., Pallas-Areny, R., Riu, P. J. andLozano, A. (1991): ‘Electrode noise in high resoloution ECG’,IV Int. Symp. on Biomedical Engineering, Pensicola, Spain, pp. 103–104

  • Fernandez, M., andPallas-Areny, R. (1992): ‘Electrode contact noise in surface biopotential measurements’. 14th Ann. Int. Conf. of IEEE Engineering in Medicine and Biology Soceity. Paris, pp. 123–124

  • Ferris, C. D., andStewart, L. R. (1974): ‘Electrode-produced signal distortion in electrophysiological recording systems’,IEEE Trans.,BME-21, pp. 318–326

    Google Scholar 

  • Fitch, P. (1973): ‘Signal/noise ratio in the recording of human nerve-action potentials’,Med. Biol. Eng.,11, pp. 146–154

    Article  Google Scholar 

  • Flasterstein, A. H. (1966a): ‘Voltage fluctuations of metal electrolyte interfaces in electrophysiology’,Med. Biol. Eng. Comput.,4, pp. 583–588

    Google Scholar 

  • Flasterstein, A. H. (1966b): ‘A general analysis of voltage fluctuations of metal-electrolyte interfaces’,Ibid.,4, pp. 589–594

    Google Scholar 

  • Fleischmann, M., andOldfield, J. W. (1970): ‘Generation-recombination noise in weak electrolytes’,J. Electroanal. Chem.,27, pp. 207–218

    Article  Google Scholar 

  • Gabrielli, G., Huet, F., andKeddam, M. (1986): ‘Investigation of electrochemical processes by an electrochemical noise analysis. Theoretical and experimental aspects in potentiostatic regime’,Electrochim. Acta,31, pp. 1025–1039

    Article  Google Scholar 

  • Gabrielli, C., Huet, F., andKeddam, M. (1993): ‘Fluctuations in electrochemical systems. II-Application to a diffusion limited redox process’,J. Chem. Phys.,99, pp. 7240–7252

    Article  Google Scholar 

  • Godin, D. T., Parker, P. A., Scott, R. N. (1991): ‘Noise characteristics of stainless-steel surface electrodes’,Med. Biol. Eng. Comput.,29, pp. 585–590

    Article  Google Scholar 

  • Gondran, C., Siebert, E., Fabry, P., Novakov, E., andGumery, P. Y. (1992): ‘NASICON based electrodes for bioelectric signal measurements’. 14th Ann. Int. Conf. of IEEE Engineering in Medicine and Biology Society, Paris, pp. 2706–2708

  • Gondran, C., Siebert, E., Fabry, P., Novakov, E., andGumery, P. Y. (1995a): ‘Non-polarisable dry elecrode based in NASICON ceramic’,Med. Bio. Eng. Comput.,33, pp. 452–457

    Article  Google Scholar 

  • Gondran, C., Siebert, E., Yacoub, S., andNovakov, E. (1995b): ‘Dry electrode based on NASICON ceramic for surface biopotential measurements: skin-electrode impedance and noise’,Innov. Tech. Biol. Med.,16, pp. 113–118

    Google Scholar 

  • Inbar, G. F., andNoumaim, A. E. (1984): ‘On surface E.M.G. spectral characterization and its application to diagnostic classification,’IEEE Trans.,BME-31, pp. 597–604

    Google Scholar 

  • Nightingale, A. (1958): ‘Electrical noise from polarization cells and from human tissues’,Nature,181, pp. 192–193

    Article  Google Scholar 

  • Nightingale, A. (1959): ‘Background noise in electromyography’,Phys. Med. Biol.,3, pp. 325–338

    Article  Google Scholar 

  • Nyquist, H. (1928): ‘Thermal agitation of electric charge in conductors’,Phys. Rev.,32, pp. 110–113

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Additional information

Reprint requests and correspondence should be addressed to Frist

Rights and permissions

Reprints and permissions

About this article

Cite this article

Gondran, C., Siebert, E., Yacoub, S. et al. Noise of surface bio-potential electrodes based on NASICON ceramic and Ag−AgCl. Med. Biol. Eng. Comput. 34, 460–466 (1996). https://doi.org/10.1007/BF02523851

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02523851

Keywords

Navigation