Abstract
The pulse transmission ultrasonic technique is used to characterise the actual pathway and the wavelength dependence in relation to the bone specimen and microstructural dimensions. The average velocity through individual trabecular bone is 2901 m s−1 (SD 161), and the mean velocity through cylindrical cancellous bone specimens is 2717 m s−1 (SD 171). Thus, the velocity through the cylindrical cancellous bone specimens is underestimated by as much as 6.4% of that through individual trabeculae. There is statistically significant difference in the ultrasonic velocity between individual trabeculae and cylindrical cancellous bone specimens (p=0.0012).
Similar content being viewed by others
References
Ashman, R. B., Corin, J. D., andTurner, C. H. (1987): ‘Elastic properties of cancellous bone: measurement by an ultrasonic technique’,J. Biomech.,20, pp. 979–986
Ashman, R. B., andRho, J. Y. (1988): ‘Elastic modulus of trabecular bone material’,J. Biomech.,21, pp. 177–181
Ashman, R. B., Rho, J. Y., andTurner, C. H. (1989): ‘Anatomical variation of orthotropic elastic moduli of the proximal human tibia’,J. Biomech.,22, pp. 895–900
Choi, K., Kuhn, J. L., Ciarelli, M. J., andGoldstein, S. A. (1990): ‘The elastic moduli of human subchondral trabecular, and cortical bone tissue and the size-dependency of cortical bone modulus’,J. Biomech.,23, pp. 1103–1113
Glüer, C., Blake, G., Lu, Y., Blunt, B. A., Jergas, M. andGenant, H. K. (1995): ‘Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques’,Osteoporosis Int 5, pp. 262–270
Harrigan, T. P., andMann, R. W. (1984): ‘Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor’,J. Mater. Sci.,19, pp. 761–767
Langton, C. M., Ali, A. V., Riggs, C. M., Evans, G. P., andBonfield, W. (1990): ‘A contact method for the assessment of ultrasonic velocity and broadband attenuation in cortical and cancellous bone’,Clin. Phys. Physiol. Meas.,11, pp. 243–249
Martin, R. B. (1991): ‘Determinants of the mechanical properties of bones’,J. Biomech.,24 (suppl. 1), pp. 79–88
McCartney, R. N., Jeffcott, L. B., andMcCarthy, R. N. (1995): ‘Transverse path of ultrasound waves in thick-walled cylinders’,Med. Biol. Eng. Comput.,33, pp. 551–557
Roy, M., Rho, J. Y., Tsui, T. Y., andPharr, G. M. (1996): ‘Variation of Young's modulus and hardness in human lumbar vertebrae measured by nanoindentation’,Adv. Bioeng. BED-33, pp. 385–386
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Rho, J.Y. Ultrasonic characterisation in determining elastic modulus of trabecular bone material. Med. Biol. Eng. Comput. 36, 57–59 (1998). https://doi.org/10.1007/BF02522858
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02522858