Abstract

The pulse transmission ultrasonic technique is used to characterise the actual pathway and the wavelength dependence in relation to the bone specimen and microstructural dimensions. The average velocity through individual trabecular bone is 2901 m s−1 (SD 161), and the mean velocity through cylindrical cancellous bone specimens is 2717 m s−1 (SD 171). Thus, the velocity through the cylindrical cancellous bone specimens is underestimated by as much as 6.4% of that through individual trabeculae. There is statistically significant difference in the ultrasonic velocity between individual trabeculae and cylindrical cancellous bone specimens (p=0.0012).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Ashman, R. B., Corin, J. D., andTurner, C. H. (1987): ‘Elastic properties of cancellous bone: measurement by an ultrasonic technique’,J. Biomech.,20, pp. 979–986

    Article  Google Scholar 

  • Ashman, R. B., andRho, J. Y. (1988): ‘Elastic modulus of trabecular bone material’,J. Biomech.,21, pp. 177–181

    Article  Google Scholar 

  • Ashman, R. B., Rho, J. Y., andTurner, C. H. (1989): ‘Anatomical variation of orthotropic elastic moduli of the proximal human tibia’,J. Biomech.,22, pp. 895–900

    Article  Google Scholar 

  • Choi, K., Kuhn, J. L., Ciarelli, M. J., andGoldstein, S. A. (1990): ‘The elastic moduli of human subchondral trabecular, and cortical bone tissue and the size-dependency of cortical bone modulus’,J. Biomech.,23, pp. 1103–1113

    Article  Google Scholar 

  • Glüer, C., Blake, G., Lu, Y., Blunt, B. A., Jergas, M. andGenant, H. K. (1995): ‘Accurate assessment of precision errors: how to measure the reproducibility of bone densitometry techniques’,Osteoporosis Int 5, pp. 262–270

    Article  Google Scholar 

  • Harrigan, T. P., andMann, R. W. (1984): ‘Characterization of microstructural anisotropy in orthotropic materials using a second rank tensor’,J. Mater. Sci.,19, pp. 761–767

    Article  Google Scholar 

  • Langton, C. M., Ali, A. V., Riggs, C. M., Evans, G. P., andBonfield, W. (1990): ‘A contact method for the assessment of ultrasonic velocity and broadband attenuation in cortical and cancellous bone’,Clin. Phys. Physiol. Meas.,11, pp. 243–249

    Article  Google Scholar 

  • Martin, R. B. (1991): ‘Determinants of the mechanical properties of bones’,J. Biomech.,24 (suppl. 1), pp. 79–88

    Article  Google Scholar 

  • McCartney, R. N., Jeffcott, L. B., andMcCarthy, R. N. (1995): ‘Transverse path of ultrasound waves in thick-walled cylinders’,Med. Biol. Eng. Comput.,33, pp. 551–557

    Google Scholar 

  • Roy, M., Rho, J. Y., Tsui, T. Y., andPharr, G. M. (1996): ‘Variation of Young's modulus and hardness in human lumbar vertebrae measured by nanoindentation’,Adv. Bioeng. BED-33, pp. 385–386

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to J. Y. Rho.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Rho, J.Y. Ultrasonic characterisation in determining elastic modulus of trabecular bone material. Med. Biol. Eng. Comput. 36, 57–59 (1998). https://doi.org/10.1007/BF02522858

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02522858

Keywords

Navigation