Abstract
An experimental animal hypoxia model has been developed. It consists of two sensors (an in vitro and in vivo model), an experimental device and a computer signal processing system. This method can easily be applied to determine and analyse blood oxygen saturation at various hypoxia levels. It can also be used to evaluate the accuracy of pulse oximetry over a wide range of oxyhemoglobin desaturation levels. The DC and AC components of recorded red and infra-red signals, the dual-wavelength ratio R12 and the reading of a pulse oximeter (SpO2) can be automatically calculated and displayed on a computer screen. Preliminary results of the animal hypoxia test indicate that the measurements made by the instrument correlate well with the oxygen saturation readings of the automatic blood gas analyser AVL945. The computer analysis system is suitable for repeated estimations in the animal model.
Similar content being viewed by others
References
Klose, H. J., Volger, E., Brechtelsbauer, H., Heinich, L. andSchmid-Schönbein, H. (1972): ‘Microbiology and light transmission of blood, I and II’,Pflügers Arch.,333, pp. 126–155
Lindberg, L. G. (1991): ‘Photoplethysmography-methodological studies and applications’, Biomedical Engineering dissertation 262, Linköping University, Sweden
Rodrigo, F. A. (1953): ‘The determination of the oxygenation of blood in vitro by using reflected light’,Amer. Heart J.,45, pp. 809–822
Shimada, Y., Nakashima, K.et al. (1991): ‘Evaluation of new reflectance pulse oximeter for clinical applications’,Med. Biol. Eng. Comput.,29, pp. 557–561
Steink, J. M. andShepherd, A. P. (1986): ‘Role of light scattering in whole blood oximetry’,IEEE Trans.,BME-33, pp. 294–301
Takatani, S., Noda, H., Takano, H. andAkutsu, T. (1988): ‘A miniature hybrid reflection-type optical sensor for measurement of Hemoglobin content and oxygen saturation of whole blood’,IEEE Trans.BME-35, pp. 187–197
Tremper, K. andBarker, S. (1989): ‘Pulse oximetry’,Anesthesiol.,70, pp. 98–108
Vegfors, M., Lindberg, L. G., Öberg, P. A. andLennmarken, C. (1993): ‘Accuracy of pulse oximetry at various haematocrits and during haemolysis in an in vitro model’,Med. Biol. Eng. Comput.31, pp. 135–141
Yoshiya, I., Shimada, Y. andTanaka, K. (1980): ‘Spectrophotometric monitoring of arterial oxygen saturation in the fingertip’,Med. Biol. Eng. Comput.,18, pp. 27–32
Yoshiya, I. andShimada, Y. (1983): ‘Non-invasive spectrophotometric estimation of arterial oxygen saturation in non-invasive physiological measurements’, vol. 2. ROLFE, P. (Ed.) Academic Press, pp. 251–286
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Yang, Y.X., Xie, B.S., Zhou, Z.X. et al. Computer analysis system of blood oxygen saturation in an animal hypoxia model. Med. Biol. Eng. Comput. 36, 355–358 (1998). https://doi.org/10.1007/BF02522483
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF02522483