Quantitative analysis of errors due to power-line interference and base-line drift in detection of onsets and offsets in ECG using wavelets

  • Communication
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

Timing characterisation of the ECG using wavelet transforms is a new technique in which multiscale analysis reduces the influence of noise. This technique issued to investigate the effect of noise and to estimate the errors involved in the detection of onsets and offsets of ECG waves. With appropriate choice of scales of analysis the study shows that the errors involved in the measurement of QRS width in the presence of base-line wander are negligible. The 50 Hz power-line interference introduces a maximum error of 6.25% if it is greater than 50% of the signal amplitude. The P and T complexes are not affected by power-line interference, but the base-line wander introduces a maximum error of 9.6%. In situations with the simultaneous presence of both types of noise, the use of an optimised scale restricts the errors to within clinically acceptable limits.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Christov, I., andDotsinsky, I. A. (1988): ‘A new approach to digital elimination of 50 Hz interference from the electrocardiogram,’Med. Biol. Eng. Comput.,26, pp. 431–434

    Article  Google Scholar 

  • Christov, I. I., Dotsinsky, A. I., andDaskalov, I. K. (1992): ‘High pass filtering of ECG signals using QRS elimination,’Med. Biol. Eng. Comput.,30, pp. 253–256

    Article  Google Scholar 

  • Chui, C. K. (1992): ‘An introduction to wavelets’ (Academic Press, Inc.)

  • CSE Working Party (1985), Recommendations for measurement standard in quantitative electrocardiography,’Eur. Heart J.,6, 815–825

    Google Scholar 

  • Cuiwei, I. I., Congxum, Z., Changfeng, T. A. I. (1995): ‘Detection of ECG characteristics points using wavelet transforms,IEEE Trans.,BME-42, (1), pp. 22–28

    Google Scholar 

  • Daubechies, I. (1990): ‘The wavelet transform: A method of time frequency localization’in Haykin, S. (Ed.): ‘Advances in spectral analysis’ (Prentice Hall, New York)

    Google Scholar 

  • Levkov, C., Michov, G., Ivanov, R., andDaskalov, I. K. (1984): ‘Subtraction of 50 Hz interference from the electrocardiogram,’Med. Biol. Eng. Comput.,22, pp. 371–373

    Article  Google Scholar 

  • Mallat, S. (1989): ‘Multiresolution frequency channel decompositions of images and wavelet models’,IEEE Trans.,ASSP-37, (12), pp. 2091–2110

    Google Scholar 

  • Mallat, S. (1991): ‘Zero crossings of wavelet transform,’IEEE Trans. Inf. Theory,37, (4), pp. 1019–1033

    Article  MathSciNet  Google Scholar 

  • Rioul, O, andVetterli, M. (1991): ‘Wavelet and signal processing,’IEEE Signal Process. Mag., (Oct), pp. 14–38

  • Sahambi, J. S., Tandon, S. N., andBhatt, R. K. P. (1997) ‘Using wavelet transforms for ECG characterisations’,IEEE Eng. Med. Biol.,16, (1), pp. 77–83.

    Article  Google Scholar 

  • Sahambi, J. S., Tandon, S. N., andBhatt, R. K. P. (1996b): ‘On new approach for on-line characterization of ECG’s proc. 15th Southern Biomedial Engineering Conf., March 29–31, Dayton USA, pp. 409–411

  • Thakor, N. V., Webstor, J. G., andTompkins, W. J. (1984): ‘Estimation of QRS complex power spectra for design of a QRS filter,IEEE Trans. Biomed. Eng.,BME-31, (11), pp. 702–705.

    Google Scholar 

  • van Alste, J. E., andSchilder, T. S. (1986): ‘Removal of base-line wander and power frequency interference from ECG by an efficient filter with reduced number of taps,’IEEE Trans. Biomedical Eng.,BME-32, (12) pp. 1052–1060

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to S. N. Tandon.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sahambi, J.S., Tandon, S.N. & Bhatt, R.K.P. Quantitative analysis of errors due to power-line interference and base-line drift in detection of onsets and offsets in ECG using wavelets. Med. Biol. Eng. Comput. 35, 747–751 (1997). https://doi.org/10.1007/BF02510988

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02510988

Keywords

Navigation