Abstract

A new implantable bladder volume-monitoring device based on the impedance measurement of the detrusor muscle is described. The system is completely autonomous and forms a mixed-signal (analogue/digital) feedback loop with a neuro-stimulator to rectify bladder dysfunctions (incontinence and retention) through neuromuscular stimulation techniques. A programmable instrumentation amplifier and a signal processing block, to eliminate the artefacts caused by the patient’s movements, have been designed and tested. The layout for the signal processing block has been realised in 0.8 μm BiCMOS technology.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Arabi, K., andSawan, M. (1996): ‘Implantable multiprogrammable microstimulator dedicated to bladder control’,Med. Biol. Eng. Comput.,34, pp. 9–12

    Google Scholar 

  • Brindley, G. S. (1994): ‘The first 500 patients with sacral anterior root stimulator implants: general description’,Paraplegia,32, pp. 795–805

    Google Scholar 

  • Denniston, J. C. andBaker, L. E. (1975): ‘Measurement of urinary bladder emptying using electrical impedance’,Med. Biol. Eng. Comput., pp. 305–306

  • Koldewijn, E. L., van Kerrebroeck, P. H. E., Schaafsma, E., Wijkstra, H. andDebruyne, F. M. J. (1994): ‘Bladder pressure sensors in an animal model’,J. Urol.,151, pp. 1379–1384

    Google Scholar 

  • Li, J. S., Hassouna, M., Sawan, M., Duval, F. andElhilali, M. M. (1992): ‘Role of electric stimulation in bladder evacuation following spinal cord transection’,J. Urol.,147, pp. 1429–1434

    Google Scholar 

  • Nashold, B. S., Friedman, H., andBoyarsky, R. (1971). ‘Electrical activation of micturition by spinal cord stimulation’,J. Surg. Res.,11 (3), pp. 144–147

    Article  Google Scholar 

  • Provost, B. andSawan, M. (1995): ‘A new implantable tomography approach to bladder volume monitoring’, Proc. 17th. Int. Conf. IEEE/EMBS (Montréal)

  • Rijkhoff, N. J. M., Koldewin, E. L., van Kerrebroeck, P. E. V., Debruyne, F. M. J. andWijkstra, H. (1993): ‘Sacral root stimulation in the dog: reduction of urethral resistance’, IEEE EMBS’93 (San Diego) pp. 1257–1258

  • Sawan, M., Hassouna, M., Li, J. S., Duval, F., andElhilali, M. M. (1996): ‘Stimulator design and subsequent stimulation parameter optimisation for controlling micturition and reducing urethral resistance’,IEEE Trans. Rehab. Eng.,4, (1), pp. 39–46

    Article  Google Scholar 

  • Takayama, K., Takei, M., Soejima, T., andKumazawa, J. (1987): ‘Continuous monitoring of bladder pressure in dogs in a completely physiological state’,Br. J. Urol.,60, pp. 428–432

    Google Scholar 

  • Talibi, M. A., Drolet, R., Kunov, H., andRobinson, C. J. (1970): ‘A model for studying the electrical stimulation of the urinary bladder of dogs’,Br. J. Urol.,42, pp. 56–65

    Article  Google Scholar 

  • Tanagho, E. A., andSchmidt, R. A. (1988): ‘Electrical stimulation in the clinical management of the neurologic bladder’,J. Urol.,140, pp. 1331–1339

    Google Scholar 

  • Webster, J. G. (1990): ‘Electrical impedance tomography’, (Hilger, Bristol, England) p. 224

    Google Scholar 

  • Woljen, J. A., Timm, G. W., Waltz, F. M. andBradley, W. E. (1973): ‘Bladder mobility detection using the Hall effect’,IEEE Trans. Biomed. Eng., pp. 295–299

  • Zöllner-Nielsen, M., andSamuelsson, S. M. (1992): ‘Maximal electrical stimulation of patients with frequency, urgency and urge incontinence: report of 38 cases’,Acta Obstet. Gynecol. Scand.,71, pp. 629–631

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to M. Sawan.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Provost, B., Sawan, M. Proposed new bladder volume monitoring device based on impedance measurement. Med. Biol. Eng. Comput. 35, 691–694 (1997). https://doi.org/10.1007/BF02510979

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02510979

Keywords

Navigation