Skip to main content
Log in

Real-time adaptive cancelling of ambient noise in lung sound measurement

  • Signal Processing
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

Ambient noise such as instrument noise and human voices often disturbs the hearing and/or measurement of lung sounds. Conventional frequency-domain filtering is usually ineffective. Noise is transmitted to the microphone that measures lung sounds through the chest wall around it, and it may be feasible to cancel out the noise by identifying this transfer function. The function, however, may vary with respect to the subject and measuring site, and therefore it should be modified dynamically. We apply an adaptive filtering technique to solve this problem. A workstation-based off-line adaptive noise canceller is developed to assess its performance in detail. Filter coefficients are controlled by a least-mean-square algorithm. Results show that the ambient noise is reduced by about 30 dB in a convergence time of several seconds. A real-time adaptive noise canceller is subsequently implemented by incorporating a digital signal processor, and a prototype electronic stethoscope is realised with high immunity to ambient noise. In a clinical application experiment in which the noise-contaminated lung souds are observed during an airway sensitivity test, satisfactory results are obtained. It is proved that the proposed method and device are effective for hearing and/or measuring lung sounds in noisy environments.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Chen, J., Vandewalle, J., Sansen, W., Vantrappen, G., Janssens, J. (1989): Adaptive method for cancellation of respiratory artefact in electrogastric measurements’,Med. Biol. Eng. Comput. 27, pp. 57–63.

    Article  Google Scholar 

  • Haykin, S. (1984): ‘Introduction to adaptive filters’ (Macmillan, New York).

    Google Scholar 

  • Iyer, V. K., Ramamoorthy, P. A., Fan, H., andPloysongsang, Y. (1986): ‘Reduction of heart sounds from lung sounds by adaptive filtering’,IEEE Trans., BME,33, pp. 1141–1163

    Google Scholar 

  • Kaneda, Y. (1989): Applications of digital filter to microphone systems-techniques for reducing undersired sound’,J. Acoust. Soc. Jpn.,45, pp. 125–128 (in Japanese)

    Google Scholar 

  • Roure, A. (1985) ‘Self-adaptive broadband active sound control system’J. Sound Vib.,101, pp. 429–441

    Google Scholar 

  • Saso, K., Yagi, S., Suzuki, A. andNakayama, K (1992): ‘Characteristics of the lung-sound microphone on the chest wall’,Jpn. J. Med. Elec. Biol. Eng.,30, pp. 261–266 (in Japanese)

    Google Scholar 

  • Widrow, B., Glover, J. R. Jr., McCool, J. R., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Dong, E. J. Jr. andGoodlin, R. C. (1975): ‘Adaptive noise cancelling: principles and applications’,Proc. IEEE 63, pp. 1692–1716

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Suzuki, A., Sumi, C., Nakayama, K. et al. Real-time adaptive cancelling of ambient noise in lung sound measurement. Med. Biol. Eng. Comput. 33, 704–708 (1995). https://doi.org/10.1007/BF02510790

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02510790

Keywords

Navigation