An integrated coupled column liquid chromatography system for the determination of leukotriene metabolites in biological samples

  • Originals
  • Published:
Chromatographia Aims and scope Submit manuscript

Summary

A fully integrated chromatographic system was developed for the determination of leukotrienes in biological samples using photodiode-array detection (PDAD), which eliminates time consuming manual sample handling steps. A special solid phase extraction, (SPE) methodology for leucotriene metabolite stability was developed which increased the recoveries and eliminates the contamination risk of biological samples. The inherent instability (autooxidation) of many of the leukotriene mediators, and the adsorption effects onto exposed surfaces in vials and in the chromatographic system were found to be very important parameters to control in order to circumvent high loss of sample analytes. By binding the cell supernatants to the functionalities of the SPE support stabilised these mediators. Cell culture samples were eluted through a disposable C18 SPE column. The SPE columns were allowed to thaw and deposited in an automated sample handling unit (ASPEC XL). Desorption of the analytes was followed by a second on-line SPE step, to eliminate remaining interfering matrix compounds. Typical recoveries when stored at −70°C were in-between 55–97% except for (LTE4) which was found to be around 40% after 72 days of storage. Seven reversed-phase packings were studied. Selectivity factors, as well as the separation efficiencies, were found to differ for the various C18 bonded silica stationary phases. This integrated on-line column liquid chromatographic system was applied to the determination of leukotriene B4, leukotriene C4, leukotriene D4, leukotriene and E4 in human cell extracts using prostaglandin B2 as the internal standard. More than 1500 biological samples were analysed. Some validation data are presented for unattended operations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. B. Samuelsson, S.-E. Dahlen, J. Å. Lindgren, C. A. Rouzer, C. N. Serhan, Science237, 1171 (1987).

    CAS  Google Scholar 

  2. R. C. Murphy, F. A. Fitzpatrick (Editors), Methods in Enzymology, Vol. 187, “Arachidonate Related Lipid Mediators”, Academic Press, London 1990.

    Google Scholar 

  3. G. Y. Lipschic, M. E. Doerfler, J. A. Kovács, W. D. Travis, V. A. Andrawis, M. G. Lawrence, J. R. Dichter, F. P. Ognibene, J. H. Shelhamer, Chest104, 763 (1993).

    Google Scholar 

  4. A. Celardo, G. D'ellElba, Z. M. Eltawy, V. Evangelista C. Cerletti, J. Chromatogr. B658, 261 (1994).

    CAS  Google Scholar 

  5. M. E. Surette, A. Odeimat, R. Palmantier, S. Marleau, P. E. Poubelle P. Borgeat, Anal. Biochem.216, 392 (1994).

    Article  CAS  Google Scholar 

  6. K. Shindo, M Fukumura, K. Miyakawa, Eur. Respir. J.8, 605 (1995).

    CAS  Google Scholar 

  7. I. Ramis, G. Hotter, J. Roselló-Catafau, O. Bulbena, C. Picado, E. Gelpi, J. Pharm. Biomed. Anal.11, 1135 (1993).

    Article  CAS  Google Scholar 

  8. D. Nicoll-Griffith, R. Zamboni, J. B. Rasmussen, D. Eithier, S. Charleson, P. Tagari, J. Chromatogr. B.526, 341 (1990).

    CAS  Google Scholar 

  9. P. Tagari, D. Ethier, M. Carry, V. Korley, S. Charleson, Y. Girard, R. Zamboni, Clin. Chem.35/3, 388 (1989).

    Google Scholar 

  10. G. Hotter, I. Ramis, G. Bioque, C. Sarmiento, J. M Fernandez, J. Roselló-Catafau, E. Gelpi, Chromatographia36, 33 (1993).

    Article  CAS  Google Scholar 

  11. I. Ramis, J. Rosseló-Catafau, M Artigot, O. Bulbena, C. Picado, E. Gelpi, J Chromatogr.532, 217 (1990).

    CAS  Google Scholar 

  12. I. Ramis, G. Hotter, J. Rosseló-Catafau, O. Bulbena, C. Picado, E. Gelpi, J. Pharm. Biomed. Analysis.11, 1139 (1993).

    Article  Google Scholar 

  13. L. Heintz, G. Hallström, E. Österlind, U. Alkner, G. Marko-Varga, unpublished results.

  14. A. Oosterkamp, H. Irth, L. Heintz, G. Marko-Varga, U. R. Tjaden, J. van der Greef, al. Chem.68, 4101 (1996).

    CAS  Google Scholar 

  15. A. Oosterkamp, H. Irth, L. Heintz, G. Marko-Varga, S. Kjellström, U. Alkner, J. Clin. Ligand Assay20, 40 (1997).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Heintz, L., Österlind, E., Alkner, U. et al. An integrated coupled column liquid chromatography system for the determination of leukotriene metabolites in biological samples. Chromatographia 46, 365–373 (1997). https://doi.org/10.1007/BF02490874

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02490874

Key Words

Navigation