Computer matched filter location of fetalR-waves

  • Published:
Medical and biological engineering Aims and scope Submit manuscript

Abstract

Statistical decision theory indicates that the best way to locate a signal of known waveshape is to use a matched filter. The degree of improvement actually achieved is investigated using actual signals of varying signal-to-noise ratio in which the maternal complex has been automatically eliminated by computer processing. It is shown that a simplified 3-point version of the matched filter provides almost as much improvement with the added advantage that prior knowledge of the fetal waveshape is not required. It is possible to improve the performance further by using a two-stage process that exploits the almost-periodic characteristic of the fetal ECG.

Sommaire

Le calcul statistique montre que la meilleure façon de localiser un signal de forme d’onde connue est d’utiliser un filtre adapté. Le degré de résolution réellement atteint est obtenu enutilisant des signaux réels dont le rapport signal sur bruit est variable, et dans lequel le complexe maternel a été automatiquement éliminé par calculateur. On montre qu’une version simplifiée due filtre adapté offre une aussi bonne résolution, avec l’avantage qu’il n’est pas nécessaire de connaître à l’avance la forme de l’onde foetale. Il est possible d’améliorer encore la performance en utilisant un processus èn deux étapes qui exploite la caractéristique quasi-périodique de l’ECG foetal.

Zusammenfassung

Aus der Entscheidungstheorie der Statistik geht hervor, daß ein Signal bekannter Wellenform am besten mit Hilfe eines angepaßten Filters lokalisiert wird. Der gegenwärtig erreichte Stand wird mit Signalen verschiedenen Signal/Rausch-Verhältnisses untersucht dabei wird der mütterliche Komplex durch Datenverarbeitung automatisch eliminiert. Es wird gezeigt, daß eine vereinfachte 3-Punkte-Version des angepaßten Filters fast diesen Stand erreicht. Ein zusätzlicher Vorteil ist, daß die fetale Wellenform nicht im voraus bekannt sein muß. Eine weitere Verbesserung ist durch Benutzung eines Zweistufenverfahrens möglich, bei dem die fast periodische Charakteristik des fetalen EKG ausgenutzt wird.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Favret, A. G. andMarchetti, A. A. (1966) Fetal electrocardiograph wave forms from abdominal wall recordings.Obstet. Gynec. 27, 355–362.

    Google Scholar 

  • Goddard, B. A., Newell, J. A., Edwards, R. L. andFarr, R. F. (1966) A clinical foetal electrocardiograph.Med. Electron. biol. Engng 4, 159–67.

    Google Scholar 

  • Hon, E. H. andHess, O. W. (1957) Instrumentation of fetal ECG.Science 125, 533–54.

    Google Scholar 

  • Hon, E. H. andHuang, H. S. (1962) The electronic evaluation of fetal heart rate-VII: Premature and missed beats.Obstet. Gynec. 20, 81–90.

    Article  Google Scholar 

  • Hon, E. H. andLee, S. T. (1963) Noise reduction in fetal electrocardiograph—II: Averaging techniques.Am. J. Obstet. Gynec. 87, 1086–1096.

    Google Scholar 

  • Maio, R. A. (1967) Detection of almost periodic signals using an adaptive optimum filter. Master’s Thesis, Catholic University of America, Washington, D.C.

    Google Scholar 

  • Smyth, C. M. (1953) Experimental electrocardiography of the fetus.Lancet i, 1124–26.

    Article  Google Scholar 

  • Steinberg, C. A., Abraham, S. andCaceres, C. A. (1962) Pattern recognition in clinical electrocardiogram.I.E.E.E. Trans. Bio-Med. Electron. BME-9, 23–30.

    Article  Google Scholar 

  • Sureau, C. andTrocellier, R. (1963) Etude de quelques problems techniques en electrocardiographie foetale.Med. Electron. biol. Engng 1, 181–88.

    Article  Google Scholar 

  • Turin, G. L. (1960) An introduction to matched filters.I. R. E. Trans. Inform. Theory IT-6, 311–329.

    Article  MathSciNet  Google Scholar 

  • Van Bemmel, J. H. andVan Der Weide, H. (1966) Detection procedure to represent the foetal heart rate and electrocardiogram.I.E.E.E. Trans. Bio.-Med. Electron. BME-9, 175–182.

    Google Scholar 

  • Van Bemmel, J. H. (1967) Private communication.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Favret, A.G. Computer matched filter location of fetalR-waves. Med. & biol. Engng. 6, 467–475 (1968). https://doi.org/10.1007/BF02474285

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02474285

Keywords

Navigation