Abstract
A physical model is developed for the simulation of the left heart and systemic circulation. The simulator includes a transparent and compliant ventricle pumping into an arterial model. The ability of the system to reproduce thein vivo conditions accurately is demonstrated by quantitative comjcarisons with physiological pressure and flow waveforms. As an example of application, flow patterns within the ventricle obtained by visualisation techniques and ultrasonic Doppler velocimetry are presented. Its versatility makes the system an essential tool in cardiovascular flow dynamics.
Similar content being viewed by others
References
Alchas, P. G., Snyder, A. J. andPhillips, W. M. (1980) Pulsatile prosthetic valve flows: laser-Doppler studies. InBiofluid mechanics.Schneck, D. (Ed.), Plenum Press, New York.
Bellhouse, B. J. (1972) The fluid mechanics of heart valves. InCardiovascular fluid dynamics.Bergel, D. H. (Ed.), Academic Press, London.
Cornhill, J. F. (1977) An aortic-left ventricular pulse duplicator used in testing prosthetic aortic heart valves.J. Thorac. Cardiovasc. Surg.,73, 550–558.
Gessner, U. (1972) Vascular input impedance. InCardiovascular fluid dynamics.Bergel, D. H. (Ed.), Academic Press, London.
Hwang, N. H. C. (1977) An engineering survey of problems in cardiovascular flow dynamics. InCardiovascular flow dynamics and measurements.Hwang, N. H. C. andNormann, N. A. (Eds.), University Park, Baltimore.
Issartier, P., Siouffi, M. andPelissier, R. (1978) Simulation of blood flow by a hydrodynamic generator.Med. Progr. Technol.,6, 39–40.
Issartier, P., Pelissier, R. andSiouffi, M. (1980) Projet de pompe de circulation. 5ème Congrès Français de Biomécanique, Bordeaux, September 1980.
Levine, M. D., Rosen, A. L., de Woskin, R. andMoss, G. S. (1977) Application of self-modelling non linear regression to ventricular pressure data.Comput. Biomed. Res.,10, 363–372.
Mills, C. J., Gabe, I. T., Gault, J. H., Mason, D. T., Ross, J. Jr., Braunwald, E. andShillingford, J. P. (1970) Pressure-flow relationships and vascular impedance in man.Cardiovasc. Res.,4, 405–417.
Oddou, C., Brun, P., Dantan, P., Beraldo, E., Kulas, A. andde Vernejoul, F. (1977) Fluid mechanics in the human left ventricle during cardiac filling phase. InCardiovascular and pulmonary dynamics.Jaffrin, M. Y. (Ed.), INSERM, Paris.
Reul, H. (1983) Cardiovascular simulation models. Xth ESAO, Bologna, September 1983.
Rieu, R., Issartier, P., Pelissier, R., Mouttet, J. P., Palomba, P. andPeronneau, P. (1979) Experimental investigation of the flow in a vascular bifurcation. EUROMECH 118, Cardiovascular and Pulmonary Dynamics, Zuoz, August 1979.
Roshke, E. J. (1973) An engineer’s view of prosthetic heart valve performance.Biomat. Med. Dev. Art. Org.,1, 249–290.
Scotten, I. N., Walker, D. K. andBrownlee, R. T. (1979) Construction and evaluation of a hydromechanical simulation facility for the assessment of mitral valve prostheses.J. Med. Eng. Technol.,3, 11–18.
Siouffi, M., Doffin, J. andIssartier, P. (1977a) Banc d’essai d’écoulements pulsés—application a l’hémodynamique.J. Physiol.,73, 997–1004.
Siouffi, M., Peronneau, P., Wildt, F. andPelissier, R. (1977b) Modifications of flow patterns induced by a vascular stenosis. InCardiovascular and pulmonary dynamics.Jaffrin, M. Y. (Ed.), INSERM, Paris.
Swanson, W. M. andClark, R. E. (1977) Cardiovascular system simulation requirements.J. Bioeng.,1, 121–133.
Westerhof, N., Elzinga, G. andSipkema, P. (1971) An artificial arterial system for pumping hearts.J. Appl. Physiol.,31, 776–781.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Cassot, F., Morvan, D., Issartier, P. et al. New versatile physical model fitting the systemic circulation accurately. Med. Biol. Eng. Comput. 23, 511–516 (1985). https://doi.org/10.1007/BF02455304
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02455304