Skip to main content
Log in

Preferential activation of different I waves by transcranial magnetic stimulation with a figure-of-eight-shaped coil

  • Research Article
  • Published:
Experimental Brain Research Aims and scope Submit manuscript

Abstract

Transcranial magnetic stimulation (TMS) over the human primary motor cortex (M1) evokes motor responses in the contralateral limb muscles. The latencies and amplitudes of those responses depend on the direction of induced current in the brain by the stimuli (Mills et al. 1992, Werhahn et al. 1994). This observation suggests that different neural elements might be activated by the differently directed induced currents. Using a figure-of-eight-shaped coil, which induces current with a certain direction, we analyzed the effect of direction of stimulating current on the latencies of responses to TMS in normal subjects. The latencies were measured from surface electromyographic responses of the first dorsal interosseous muscles and the peaks in the peristimulus time histograms (PSTHs) of single motor units from the same muscles. The coil was placed over the M1, with eight different directions each separated by 45°. Stimulus intensity was adjusted just above the motor threshold while subjects made a weak tonic voluntary contraction, so that we can analyse the most readily elicited descending volley in the pyramidal tracts. In most subjects, TMS with medially and anteriorly directed current in the brain produced responses or a peak that occurred some 1.5 ms later than those to anodal electrical stimulation. In contrast, TMS with laterally and posteriorly directed current produced responses or a peak that occurred about 4.5 ms later. There was a single peak in most of PSTHs under the above stimulation condition, whereas there were occasionally two peaks under the transitional current directions between the above two groups. These results suggest that TMS with medially and anteriorly directed current in the brain readily elicits I1 waves, whereas that with laterally and posteriorly directed current preferentially elicits I3 waves. Functional magnetic resonance imaging studies indicated that this direction was related to the course of the central sulcus. TMS with induced current flowing forward relative to the central sulcus preferentially elicited I1 waves and that flowing backward elicited I3 waves. Our finding of the dependence of preferentially activated I waves on the current direction in the brain suggests that different sets of cortical neurons are responsible for different I waves, and are contrarily oriented. The present method using a figure-of-eight-shaped coil must enable us to study physiological characteristics of each I wave separately and, possibly, analyse different neural elements in M1, since it activates a certain I wave selectively without D waves or other I waves.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Amassian VE, Stewart M, Quirk GJ, Rosenthal JL (1987) Physiological basis of motor effects of a transient stimulus to cerebral cortex. Neurosurgery 20: 74–93

    PubMed  CAS  Google Scholar 

  • Amassian VE, Cracco RQ, Maccabee PJ (1989) Focal stimulation of human cerebral cortex with the magnetic coil: a comparison with electric stimulation. Electroencephalogr Clin Neurophysiol 74: 401–416

    Article  PubMed  CAS  Google Scholar 

  • Amassian VE, Quirk GJ, Stewart M (1990) A comparison of corticospinal activation by magnetic coil and electrical stimulation of monkey motor cortex. Electroencephalogr Clin Neurophysiol 77: 390–401

    Article  PubMed  CAS  Google Scholar 

  • Amassian VE, Eberle L, Maccabee PJ, Cracco RQ (1992) Modelling magnetic coil excitation of human cerebral cortex with a peripheral nerve immersed in a brain-shaped volume conductor: the significance of fiber bending in excitation. Electroencephalogr Clin Neurophsiol 85: 291–301

    Article  CAS  Google Scholar 

  • Aroniadou VA, Keller A (1993) The patterns and synaptic properties of horizontal intracortical connections in the rat motor cortex. J Neurophysiol 70: 1553–1569

    PubMed  CAS  Google Scholar 

  • Asanuma H, Rosén I (1973) Spread of mono-and polysynaptic connections within cat’s motor cortex. Exp Brain Res 16: 507–520

    Article  PubMed  CAS  Google Scholar 

  • Ashby P, Zilm D (1982_ Relationship between EPSP shape and cross-correlation profile explored by computer simulation for studies on human motoneurons. Exp Brain Res 47: 33–40

    PubMed  CAS  Google Scholar 

  • Brasil-Neto JP, Cohen LG, Panizza M, Nilsson J, Roth BJ, hallett M (1992) Optimal focal transcranial magnetic activation of the human motor cortex: effects of coil orientation, shape of the induced current pulse, and stimulus intensity. J Clin Neurophysiol 9: 132–136

    Article  PubMed  CAS  Google Scholar 

  • Burke D, Hicks R, Gandevia SC, Stephen J, Woodforth I, Crawford M (1993) Direct comparison of corticospinal volleys in human subjects to transcranial magnetic and electrical stimulation. J Physiol (Lond) 470: 383–393

    CAS  Google Scholar 

  • Calancie B, Nordin M, Wallin U, Hagbarth KE (1987) Motor-unit responses in human wrist flexor and extensor muscles to transcranial cortical stimuli. J Neurophysiol 58: 1168–1185

    PubMed  CAS  Google Scholar 

  • Day BL, Rothwell JC, Thompson PD, Dick JPR, Cowan JMA, Berardelli A, Marsden CD (1987) Motor cortex stimulation in intact man. 2. multiple descending volleys. Brain 110: 1191–1209

    PubMed  Google Scholar 

  • Day BL, Dressler D, Maertens de Noordhout A, Marsden CD, Nakashima K, Rothwell JC, Thompson PD (1989) Electric and magnetic stimulation of human motor cortex: surface EMG and single motor unit responses. J Physiol (Lond) 412: 449–473

    CAS  Google Scholar 

  • Fetz EE, Gustafsson B (1983) Relation between shapes of postsynaptic potentials and changes in firing probability of cat motoneurones. J Physiol (Lond) 341: 387–410

    CAS  Google Scholar 

  • Jankowska E, Padel Y, Tanaka R (1975) The mode of activation of pyramidal tract cells by intracortical stimuli. J Physiol (Lond) 249: 617–636

    CAS  Google Scholar 

  • Kernell D, Wu CP (1967) Responses of the pyramidal tract to stimulation of the baboon’s motor cortex. J Physiol (Lond) 191: 653–672

    CAS  Google Scholar 

  • Kitagawa H, Møller AR (1994) Conduction pathways and generators of magnetic evoked spinal cord potentials: a study in monkeys. Electroencephalogr Clin Neurophsiol 93: 57–67

    Article  CAS  Google Scholar 

  • Kwan HC, MacKay WA, Murphy JT, Wong YC (1978) Spatial organization of precentral cortex in awake primates. II. Motor outputs. J Neurophysiol 41: 1120–1131

    PubMed  CAS  Google Scholar 

  • Maccabee PJ, Eberle L, Amassian VE, Cracco RQ, Rudell A, Jayachandra M (1990) Spatial distribution of the electric field induced in volume by round and figure ‘8’ magnetic coils: relevance to activation of sensory nerve fibers. Electroencephalogr Clin Neurophysiol 76: 131–141

    Article  PubMed  CAS  Google Scholar 

  • Mills KR, Boniface SJ, Schubert M (1992) Magnetic brain stimulation with a double coil: the importance of coil orientation. Electroencephalogr Clin Neurophysiol 85: 17–21

    Article  PubMed  CAS  Google Scholar 

  • Minghilleri A, Berardelli A, Cruccu G, Priori A, Manfredi M (1989) Corticospinal potentials after transcranial stimulation in humans. J Neurol Neurosurg Psychiatry 52: 970–974

    Google Scholar 

  • Murphy JT, Kwan HC, MacKay WA, Wong YC (1978) Spatial organization of precentral cortex in awake primates. III. Input-output coupling. J Neurophysiol 41: 1132–1139

    PubMed  CAS  Google Scholar 

  • Patton HD, Amassian VE (1954) Single-and multiple-unit analysis of cortical stage of pyramidal tract activation. J Neurophsiol 17: 345–363

    CAS  Google Scholar 

  • Patton HD, Amassian VE (1960) The pyramidal tract: its excitation and functions. In: Field J (ed) Handbook of physiology-neurophysiology, vol II. American Physiological Society, Washington DC, 837–861

    Google Scholar 

  • Rosenthal J, Waller HJ, Amassian VE (1967) An analysis of the activation of motor cortical neurons by surface stimulation. J Neurophysiol 30: 844–858

    PubMed  CAS  Google Scholar 

  • Rudiak D, Marg E (1994) Finding the depth of magnetic brain stimulation: a re-evaluation. Electroencephalogr Clin Neurophsiol 93: 358–371

    CAS  Google Scholar 

  • Stoney SD Jr, Thompson WD, Asanuma H (1968) Excitation of pyramidal tract cells by intracortical microstimulation: effective extent of stimulating current. J Neurophysiol 31: 659–669

    PubMed  Google Scholar 

  • Thompson PD, Day BL, Crockard HA, Calder I, Murray NMF, Rothwell JC, Marsden CD (1991) Intra-operative recording of motor tract potentials at the cervico-medullary junction following scalp electrical and magnetic stimulation of the motor cortex. J Neurol Neurosurg Psychiatry 54: 618–623

    Article  PubMed  CAS  Google Scholar 

  • Werhahn KJ, Fong JKY, Meyer BU, Priori A, Rothwell JC, Day BL, Thompson PD (1994) The effect of magnetic coil orientation on the latency of surface EMG and single motor unit responses in the first dorsal interosseous muscle. Electroencephalogr Clin Neurophsiol 93: 138–146

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sakai, K., Ugawa, Y., Terao, Y. et al. Preferential activation of different I waves by transcranial magnetic stimulation with a figure-of-eight-shaped coil. Exp Brain Res 113, 24–32 (1997). https://doi.org/10.1007/BF02454139

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02454139

Key words

Navigation