References
BROWNELL, G. L., ACKERMAN, R. H., STRAUSS, W. H., ELMALEH, D. R., COCHAVI, S., ALPERT, N., CORREIRA, J. A., KEARFOTT, K.J. and TAVERAS, J. (1980) Preliminary imaging results with l8F-2-fluoro-2-deoxy-D-glucose. J. Comput. Assist. Tomogr., 4, 473–477.
CRISTY, M. and ECKERMAN, K. F. (1987) Specific absorbed fractions of energy at various ages from internal photon sources. ORNL/TM-8381/V1. Oak Ridge National Laboratory.
HARIMA, Y., SAKAMOTO, Y., TANAKA, S. and KAWAI, M. (1986) Validity of the geometric-progression formula in approximating gamma-ray buildup factors. Nucl. Sci. Eng., 94, 24–35.
ICRP Publication 53 (1988) Radiation dose to patients from radiopharmaceuticals. Pergamon Press, Oxford.
JONES, S. C., ALVAI, A., CHRISTMAN, D., MONTANEZ, I., WOLF, A. P. and REIVICH, M. (1982) The radiation dosimetry of 2-[18F]fluoro-2-deoxy-D-glucose in man. J. Nucl. Med., 23, 613–617.
LOEVINGER, R. and BERMAN, M. (1968) A schema for absorbed dose calculation for biologically distributed radionuclides. MIRD Pamphlet 1, Ibid., 9, 7–14.
LOEVINGER, R., BUDINGER, T. F. and WATSON, E. E. (1988) MIRD Primer for absorbed dose calculations. In collaboration with MIRD Committee. The Society of Nuclear Medicine, Inc., New York.
MEJIA, A. A., NAKAMURA, T., ITOH, M., HATAZAWA, J., MATSUMOTO, M. and WATANUKI, S. (1991) Estimation of absorbed doses in human due to intravenous administration of fluorine-18-fluorodeoxyglucose in PET studies. J. Nuel. Meal, 32, 699–706.
MCELROY, W. N., BERG, S., CROCKETT, T. and HAWKINS, R. G. (1967) A computer automated iterative method for neutron flux spectra determination by foil activation. AFWL-TR-67–41, Air Force Weapons Laboratory.
NOVARIO, R. and CONTE, L. (1990) A new method for calculating the distribution of radioactivity in man measured with a whole-body counter. Health Phys., 58, 597–607.
REIVICH, M., KUHL, D., WOLF, A. et al. (1979) F-18-fluorodeoxyglucose method for the measurement of local cerebral glucose utilization in man. Circ. Res., 44, 127–137.
YAMAGUCHI, Y., TOGAWA, O. and HONMA, T. (1987) The VADMAP code to calculate the SAF of photon code description and the performance. JAERI M87–186 Japan Atomic Energy Research Institute.
Author information
Authors and Affiliations
Additional information
This work was carried out while M. Matsumoto was based at the Cyclotron & Radioisotope Center.
Rights and permissions
About this article
Cite this article
Matsumoto, M., Nakamura, T., Watabe, H. et al. Estimation of organ biodistribution and absorbed dose from external measurement with TLDs in PET studies. Med. Biol. Eng. Comput. 31 (Suppl 1), S151–S156 (1993). https://doi.org/10.1007/BF02446664
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/BF02446664