Skip to main content
Log in

60 Hz ventricular fibrillation thresholds for large-surface-area electrodes

  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

The paper describes a series of animal experiments in which large-surface-area disk electrodes were used to study the current density required for ventricular fibrillation. The electrical currents were introduced to the heart both by applying the electrodes directly to the heart and by applying the electrodes to the surface of the chest near the heart. The electrode areas studied ranged from 1000 to 30 000 mm2. The results show that, for large-area electrodes, fibrillation thresholds are determined by current density. The thresholds approach a constant value of 3·5 μA mm−2

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Geddes, L. A., Grubbs, S. S., Wilcox, P. G. andTacker, W. A. (1977) The thoracic windows for electrical ventricular ventriculation.Am. Heart J.,94, 67–72.

    Google Scholar 

  • Geddes, L. A., Foster, K. S. andVoorhees, V. D. (1983) Thoracic windows for cardiac pacing. 36th ACEMB, Sept., 20.

  • Irnich, W. (1975) Engineering concepts of pacemaker electrodes. InAdvances in pacemaker technology. Springer-Verlag, 241–272.

  • Lindemans, F. W. andDenier van der Gon, J. J. (1978) Current thresholds and liminal size in excitation of heart muscle. Cardiovasc, Res.,12, 477–485.

    Article  Google Scholar 

  • Pfeiffer, E. (1976) A model for electrically induced ventricular fibrillation. Digest 11th Int. Conf. on Med. and Biol. Eng., Ottawa, Canada, 392–393.

  • Roy, O. Z. (1975) 60 Hz ventricular fibrillation and rhythm thresholds and the nonpacing intracardiac catheter.Med. Biol. Eng.,13, 228–234.

    Google Scholar 

  • Roy, O. Z., Scott, J. R. andPark, G. C. (1976) 60 Hz ventricular fibrillation and pump failure thresholds versus electrode area.IEEE Trans.,BME-23, 45–48.

    Google Scholar 

  • Roy, O. Z. (1980) Summary of cardiac fibrillation thresholds for 60 Hz currents and voltages applied directly to the heart.Med. & Biol. Eng. & Comput.,18, 657–659.

    Article  Google Scholar 

  • Sances A. Jr., Myklebust, J. B. andSzablya, J. F. (1983) Current pathways in high voltage injuries.IEEE Trans.,BME-30, 118–124.

    Google Scholar 

  • Starmer, F. andWhalen, R. (1973) Current density and electrically induced ventricular fibrillation.Med. Instrum.,7, 3–6.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Roy, O.Z., Scott, J.R. & Trollope, B.J. 60 Hz ventricular fibrillation thresholds for large-surface-area electrodes. Med. Biol. Eng. Comput. 24, 471–474 (1986). https://doi.org/10.1007/BF02443961

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02443961

Keywords

Navigation