Skip to main content
Log in

Blood compatibility of polymers:in vitro andin vivo tests

  • Biomaterials Supplement
  • Published:
Medical and Biological Engineering and Computing Aims and scope Submit manuscript

Abstract

Synthetic materials used for medical prostheses and devices, mainly those which will come into contact with blood, have to provide for specific properties. Three in vitro blood-compatibility tests are presented; one is a screening method (m.t.e.g.) whose results show remarkable correlations to in vivo behaviour, the other two (Nosé-blood-chamber, protein adsorption) yield more basis information on synthetic surfaces. Aspects of toxicity and biodegradation should be included in the definition of ‘blood compatibility’. After preselection by in vitro tests, a material has to pass an in vivo examination in animal experiments (shunt, catheter, tube, test chamber) under haemodynamic conditions. Finally, devices or prostheses in their intended shape, such as the total artificial heart, are implanted in animals.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Affeld, K., Berger, J., Müller, R. andBücherl, E. S. (1974) A new method for an in vitro test of bloodcontact materials.Proc. Europ. Soc. Artif. Organs,1, 26–29.

    Google Scholar 

  • Brash, J. L. (1979)Hydrophobic polymers as materials for interfacing with blood.Unger, F. (Ed.): Assisted Circulation, Springer-Verlag, 506–519.

  • Bruck, S. D. (1979)Some current problems and new dimensions of polymeric biomaterials for blood contacting applications.Unger, F. (Ed.): Assisted Circulation, Springer-Verlag, 496–502.

  • Bücherl, E. S.,et al. (1979) Total artificial heart replacement.Internat. J. Artif. Organs,2, 141.

    Google Scholar 

  • Carr, S. H., Zuckermann, L. andCaprini, J. A. (1979) In vitro testing of surface thrombogenicity using the thrombelastograph. 80th National Meeting of the American Institute of Chemical Engineers.

  • Dudley, B., Williams, J. L., Able, K. andMuller, B. (1976) Synthesis and characterization of blood compatible surfaces.Trans. Am. Soc. Artif. Int. Organs,22, 538.

    Google Scholar 

  • Gott, V. I. andFuruse, A. (1971) Antithrombogenic surfaces, classification and in vivo evaluation.Fed. Proc.,30, 1679.

    Google Scholar 

  • Grosse-Siestrup, C., Unger, V. andLemm, W. (1978) A long-term ex vivo shunt for blood compatibility tests of biomaterials.Trans. Soc. Biomater.,2, 102.

    Google Scholar 

  • Grosse-Siestrup, C., Unger, V., Lemm, W. andOlsen, D. B. (1978) Externer arteriovenöser Langzeitshunt mit Testkammer für Ex-vivo-Blutverträglichkeitsuntersuchungen von Polymeroberflächen.Biomed. Technik.,23, 173.

    Article  Google Scholar 

  • Grosse-Siestrup, C., Krautzberger, W. andBücherl, E. S. (1979) Arteriovenous shunt with percutaneous leads in calves for long-term in vivo testing of blood-contact materials.J. Biomed. Mat. Res.,13, 15–22.

    Article  Google Scholar 

  • Grosse-Siestrup, C., Warnecke, I., Gerlach, K., Lemm, W. (1979) Vergleichende Untersuchung von Cava-Kathetern aus vier Polymermodifikationen.Biomed. Technik.,24, 295–296.

    Google Scholar 

  • Kusserow, B. K., Larrow, R. andNichols, J. (1970) Observations concerning prosthesis-induced thromboembolic phenomena made with an in vivo embolus test system.Trans. Am. Soc. Artif. Int. Org.,16, 58.

    Google Scholar 

  • Kaiser, M. andBücherl, E. S. (1979) In vitro tests of thrombogenicity protein adsorption and hemolytic properties of biomaterials.Proc. Europ. Soc. Artif. Organs,6, 203.

    Google Scholar 

  • Lemm, W., Unger, V., Grosse-Siestrup, C., Olsen, D. B. andBücherl, E. S. (1977) Blood compatibility tests on biomaterials on the basis of the proteinadsorption-hypothesis. Extensions and comparisons with other methods.Proc. Europ. Soc. Artif. Organs,4, 168.

    Google Scholar 

  • Lemm, W. andUnger, V. (1978) Proteinadsorption an verschiedenen Kunststoffoberflächen in vitro.Biomed. Technik.,23, (Erg.-Band), 171.

    Article  Google Scholar 

  • Lemm, W., Unger, V., Kaiser, M., Grosse-Siestrup, C. andBücherl, E. S. (1978) A comparing evaluation of three blood compatibility tests for biomaterials.Proc. Europ. Soc. Artif. Orangs,5, 29.

    Google Scholar 

  • Lemm, W., Affeld, K. andBücherl, E. S. (1979) Die modifizierte Thromboelastographie, ein geeigneter invitro-Blutverträglichkeitstest für Biomaterialien.Biomed. Technik.,24, 297.

    Google Scholar 

  • Lyman, D. J., Muir, W. M. andLee, I. J. (1965) The effect of chemical structure and surface properties of synthetic polymers on the coagulation of blood.Trans. Amer. Soc. Artif. Organs,11, 301.

    Google Scholar 

  • Lyman, D. J., Brash, J. L., Chaikin, S. W., Klein, K. G. andCarini, M. (1968) Protein and platelet interaction with polymer surfaces.Trans. Amer. Soc. Artif. Organs,14, 250.

    Google Scholar 

  • Lyman, D. J., Metcalf, L. C., Albo, D., Richards, K. F. andLamb, J. (1974) In vivo adsorption of proteins on polymer surfaces.Trans. Amer. Soc. Artif. Organs,20, 474.

    Google Scholar 

  • Lyman, D. J., Knutson, K., McNeill, B. andShibatani, K. (1975) The relation between polymer morphology and protein adsorption.Trans. Amer. Soc. Artif. Organs,21, 49.

    Google Scholar 

  • Nosé, Y. andKambic, H. (1973) Development of blood and tissue compatible materials. First Annual Report, Cleveland Clinic Foundation.

  • Rennekamp, F., Affeld, K. andBücherl, E. S. (1978) A new method for fabricating blood pumps with a seampless inner surface.Proc. Internat. Soc. Artif. Organs,2, 207.

    Google Scholar 

  • Rennekamp, F., Lemm, W. andBücherl, E. S. (1979) Long term results with seamless blood pumps out of polyurethanes for the replacement of the heart.Proc. Europ. Soc. Artif. Orangs,6, 94.

    Google Scholar 

  • Unger, V., Lemm, W. andBücherl, E. S. (1976) Kinetics of albumin and fibrinogen adsorption on biomaterials.Proc. Europ. Soc. Artif. Organs,3, 48.

    Google Scholar 

  • Warnecke, I., Wolff, D. andBücherl, E. S. (1979) Angiographische Methode zur vergleichenden Untersuchung der Thrombogenität von intravenösen Kathetern.Biomed. Technik.,24, 293.

    Article  Google Scholar 

  • Watson, J. T., Pitlick, F. A. andAltieri, F. D. (1979) Final Report to the devices and technology branch of the NHLB-Institute, 58–68.

  • Witt, I. (1975) Biochemie der Blutgerinnung und Fibrinolyse. Verlag Chemie, Weinheim, 90–92.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lemm, W., Unger, V. & Bücherl, E.S. Blood compatibility of polymers:in vitro andin vivo tests. Med. Biol. Eng. Comput. 18, 521–526 (1980). https://doi.org/10.1007/BF02443330

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02443330

Key words

Navigation